Baxi Quantum MINI circulator pump with ECM motor, three-quarter view on white background

Baxi Quantum MINI high-efficiency circulator pump for heating and cooling

Model
Regular price€161,87
/
Tax included. Shipping calculated at checkout.

  • 4 in stock
  • Backordered, shipping soon

At Q-TECH, we apply the same clear rules for everyone: the law protects you, and when applied correctly, it protects us as well. By processing your purchase, you accept our General Terms and Conditions of Sale. If you are purchasing as a consumer (B2C), nothing stated herein limits the rights granted to you by mandatory law (RDL 1/2007, TRLGDCU): the 3-year legal warranty of conformity and the right of withdrawal under the terms and with the exceptions legally provided, which are detailed below. References to "B2B" apply only to businesses and professionals.

Your guarantees

  • Rights intact: 14 days of withdrawal from receipt for most products—subject to the legal exceptions you will see below, such as goods made to your specifications—and a 3-year legal warranty of conformity, under the terms of the TRLGDCU.
  • Conformity with the description: we guarantee that the equipment will correspond to the published technical description and what one could reasonably expect from it (arts. 115 et seq. TRLGDCU). Images and videos are for guidance only: the manufacturer may supply a more recent revision of the product or introduce minor aesthetic, packaging, or firmware changes, without this constituting a lack of conformity as long as the described characteristics and performance are maintained.
  • Traceability that also protects you: we document the condition, serial number, and seal of each piece of equipment upon shipment, and we video-record the opening of returns; this is your proof of the condition in which the goods were delivered.

Responsible use and your part

  • If you are thinking of returning it, keep it as you received it: without installing or activating it, with its seals, accessories, and packaging intact. This is how to ensure a full refund, without deductions.
  • Handling that exceeds inspection reduces value: handling the equipment beyond what is necessary to verify its nature and operation may result in a real, assessed, and case-by-case justified deduction (art. 108.2 TRLGDCU), never a fixed percentage. In particular: activating or registering the serial number, linking it to a manufacturer's account or app, circulating water through hydraulic equipment, unsealing probes, or installing software or consumables. Initial inspection of the product does not lead to a deduction.
  • The same item must be returned: withdrawal requires returning the supplied unit. Different equipment, or equipment with prior use, age, or wear prior to purchase, does not constitute a valid withdrawal.
  • Installation and cybersecurity, shared responsibility: this is technical hardware; you are responsible for correct installation, credentials, patches, and backups, while we deliver a compliant product. Q-TECH is not liable for damages resulting from poor installation, incorrect configuration, or omission of patches by the customer or third parties (in B2C, without prejudice to the legal warranty and liability for intent or negligence, arts. 86 and 130 TRLGDCU).
  • Delivery of bulky goods: delivery is made to the curb. B2C: transport risk is ours until physical delivery (art. 66 ter); we recommend noting visible damages on the delivery note and notifying us of breakages within 24-48 hours with photographs to activate the insurance. B2B: inspection and notation on the delivery note are mandatory; hidden damages must be reported within 24 hours (art. 366 CCom). Unjustified rejection or incorrect shipping information will entail the actual outbound and return costs (approx. €85-550 for heavy machinery).

Made to your measure (Advanced Pre-Assembly)

  • If your order includes equipment, racks, hydraulic assemblies, or technical rooms made or configured according to your specifications (permanent joints, custom cuts or wiring, parameterization, pressure testing), these are custom goods without the right of withdrawal from the conclusion of the contract (art. 103.c TRLGDCU; CJEU Case C-529/19), which is informed before purchasing and documented in the signed Order Note. A test you request without permanent modification retains your right of withdrawal, with only the actual loss of value caused by that test being deducted. Would you prefer to receive it tested, configured, and ready to connect, without assuming these risks? Contract our Advanced Pre-Assembly or the prior technical audit.

If you are purchasing as a business or professional (B2B)

  • The transaction is governed by the Commercial Code: firm sale, without the right of withdrawal; notification of defects within 4 days (apparent) / 30 days (hidden), arts. 336 and 342. Q-TECH acts as a distributor and excludes indirect damages, loss of profit, and data loss, limited to the price of the equipment, without prejudice to the manufacturer's commercial warranty.

Product warnings v1.0 · June 2026. Information summary; the complete and binding conditions are those published at q-tech.es.

You may also be interested in...

Baxi Quantum MINI high-efficiency circulator pump for heating and cooling circuits

The Baxi Quantum MINI moves the water in your system with an ECM motor and built-in differential pressure control. Baxi makes it in three models, with 130 and 180 mm port-to-port lengths. Q-Tech integrates it into pre-assembled plant rooms, tested in our workshop together with the rest of the circuit.

Summary

TypeWet-rotor circulator pump with ECM motor
Brand and modelBaxi Quantum MINI MYL-30, 1025 and 1035
UseClosed heating and cooling circuits
Maximum flow2.7 m³ per hour (MYL-30 and 1025) and 3.5 m³ per hour (1035)
Maximum head4.2 m (MYL-30 and 1025) and 6 m (1035)
Compatible withBaxi Rp 1 or Rp 1¼ unions, sold separately
Power supply230 V single-phase
Q-Tech installationIntegrated into your pre-assembled plant room or with an on-site Expert Technician

What is the Baxi Quantum MINI?

The Baxi Quantum MINI is a wet-rotor circulator pump for heating and cooling that controls its speed with an ECM motor. It meets the ErP Directive with an energy efficiency index of 0.23 or lower. It is fitted in line, with unions, in closed water circuits.

What problem does it solve?

A fixed-speed circulator runs at the same speed even when valves close part of the circuit. It therefore uses more energy than the system needs. When replacing it, you also need a model with the same port-to-port length.

The Quantum MINI adjusts pressure automatically in Δp-v mode: when flow in the network drops, it halves the pump head. It draws 4 to 20 W in the MYL-30 and 1025, and 4 to 40 W in the 1035. Baxi offers it with 130 and 180 mm port-to-port lengths.

Technical data

TechnologyWet rotor with ECM motor
Control modesVariable differential pressure (Δp-v) and 3 fixed speeds (c1, c2 and c3)
Energy efficiency indexEEI 0.23 or lower
Electrical protectionIP X2D
Voltage230 V single-phase
Water temperature−10 to 95 °C
Maximum operating pressure6 bar
Pipe connectionWith Baxi unions, not included
Body width and depth132.8 mm and 102.3 mm

Models and data by variant

ModelPort-to-port lengthPump threadUnion (Baxi reference)Max. flow (m³ per hour)Max. head (m)Power (W)Net weight (kg)ReferenceEAN
MYL-30130 mmG 1½Rp 1 (001692635)2.74.24 to 201.6577829618431406217754
1025180 mmG 2Rp 1 (001692634)2.74.24 to 201.877829628431406217761
1035180 mmG 2Rp 1¼ (001693342)3.564 to 401.877829648431406217778

Compatibility and limits

  • Closed heating and cooling circuits with water from −10 to 95 °C and up to 6 bar.
  • Unions are not included: each model has its own Baxi set, shown in the table.
  • The MYL-30 is 130 mm port-to-port; the 1025 and 1035 are 180 mm.
  • Baxi intends it for heating and cooling; for domestic hot water recirculation it offers the SB series.

When this product is not the right choice

ProductWhen to choose itData
Baxi Quantum MAXIYou want unions included or constant pressure mode (Δp-c)6 models, 130 or 180 mm, 1 or 1¼ unions
Baxi Quantum ECOYou need more flow than the MINI8 to 55 m³ per hour, unions or flanges
Other circulator brandsYou prefer to compare with Grundfos, Wilo or DABCirculator pumps collection

Frequently asked questions

Which model do I need?

It depends on the pump you are replacing. For 130 mm port-to-port, the MYL-30; for 180 mm, the 1025 or the 1035, which gives up to 6 m head and 3.5 m³ per hour.

Are the unions included?

No. Baxi sells them separately: 001692635 for the MYL-30, 001692634 for the 1025 and 001693342 for the 1035. Message us on WhatsApp and we will quote them with the pump.

What is the difference from the Quantum MAXI?

Both use an ECM motor and an EEI of 0.23 or lower. The MAXI includes unions and adds constant pressure mode; the MINI has variable pressure and 3 fixed speeds.

Is it suitable for cooling?

Yes. Baxi specifies it for heating and cooling, with water from −10 to 95 °C.

What is the delivery time?

We have it in stock at our warehouse. If no units are left when you order, we will order it urgently and tell you the lead time.

Q-Tech installation and support

Q-Tech integrates the Quantum MINI into pre-assembled plant rooms built in our workshop: assembled, configured and tested with safety and operation checks, ready to connect on site. See how it works on Advanced Pre-Assembly and the workshop pre-assembly service. To replace a pump in an existing system, book the on-site hourly Expert Technician; for selection questions, the technical call. More models in Circulator pumps.

Documentation

Availability and lead times: this item is in stock at our warehouse. Occasionally, depending on the time of year, the stock update may contain an error. If no units are available when you place your order, we will order it urgently and inform you immediately of the updated delivery time.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.