magnetic NF 2 plus refill station with meter and shut-off valves
magnetic NF 6 plus refill station with meter and shut-off valves
magnetic NF 12 plus stainless steel vessel with outlet hose
magnetic NF 25 plus floor-standing stainless steel refill station
magnetic NF plus range to scale: NF 2, NF 6, NF 12 and NF 25 plus

magnetic NF plus refill station for demineralised heating water, VDI 2035

Model

Price on request

The final price depends on the installation, configuration and quantity. Tell us about your project and we will send you a quote with no obligation.

  1. You tell us about your project
  2. We review the technical details with you
  3. You receive a written quote
Request a quote
What do you need?

Not needed yet? Join the waiting list

Or write to info@q-tech.es · No obligation


En Q-TECH aplicamos las mismas reglas, claras y para todos: la ley te protege a ti y, bien aplicada, también nos protege a nosotros. Al tramitar la compra aceptas nuestras Condiciones Generales de Contratación. Si compras como consumidor (B2C), nada de lo aquí indicado limita los derechos que la ley te reconoce con carácter imperativo (RDL 1/2007, TRLGDCU): la garantía legal de conformidad de 3 años y el derecho de desistimiento en los términos y con las excepciones legalmente previstos, que se detallan más abajo. Las menciones «B2B» se aplican solo a empresas y profesionales.

Tus garantías

  • Derechos intactos: 14 días de desistimiento desde la recepción para la mayoría de productos —salvo las excepciones legales que verás más abajo, como los bienes hechos a tu medida— y 3 años de garantía legal de conformidad, en los términos del TRLGDCU.
  • Conformidad con lo descrito: te garantizamos que el equipo se corresponderá con la descripción técnica publicada y con lo que razonablemente quepa esperar de él (arts. 115 y siguientes TRLGDCU). Las imágenes y los vídeos son orientativos: el fabricante puede suministrar una revisión más reciente del producto o introducir cambios menores de estética, empaquetado o firmware, sin que ello constituya falta de conformidad mientras se mantengan las características y prestaciones descritas.
  • Trazabilidad que también te protege: documentamos el estado, el número de serie y el precinto de cada equipo en la expedición, y grabamos en vídeo la apertura de las devoluciones; es tu prueba del estado en que se entrega la mercancía.

Uso responsable y tu parte

  • Si estás pensando en devolverlo, consérvalo como lo recibiste: sin instalar ni activar, con sus precintos, accesorios y embalaje. Es la forma de conservar un reembolso íntegro, sin deducciones.
  • La manipulación que excede la comprobación reduce el valor: manipular el equipo más allá de lo necesario para verificar su naturaleza y funcionamiento puede generar una deducción real, tasada y motivada caso por caso (art. 108.2 TRLGDCU), nunca un porcentaje fijo. En particular: activar o registrar el número de serie, vincularlo a una cuenta o app del fabricante, hacer circular agua por equipos hidráulicos, desprecintar sondas, o instalar software o consumibles. La mera comprobación inicial del producto no conlleva deducción.
  • Se devuelve el mismo bien: el desistimiento exige devolver la unidad suministrada. Un equipo distinto, o con un uso, antigüedad o deterioro anteriores a la compra, no constituye desistimiento.
  • Instalación y ciberseguridad, responsabilidad compartida: es hardware técnico; tú te ocupas de una instalación correcta, de las credenciales, los parches y las copias de seguridad, y nosotros entregamos producto conforme. Q-TECH no responde de los daños por instalación deficiente, configuración incorrecta u omisión de parches por el cliente o por terceros (en B2C, sin perjuicio de la garantía legal y de la responsabilidad por dolo o negligencia, arts. 86 y 130 TRLGDCU).
  • Entrega de bienes voluminosos: se realiza a pie de calle. B2C: el riesgo del transporte es nuestro hasta la entrega material (art. 66 ter); te recomendamos anotar los daños visibles en el albarán y avisar de roturas en 24-48 h con fotografías para activar el seguro. B2B: revisión y anotación en albarán obligatorias; daños ocultos en 24 h (art. 366 CCom). El rechazo injustificado o unos datos de envío erróneos conllevan los costes reales de ida y retorno (orientativo, 85-550 € en maquinaria pesada).

Hecho a tu medida (Pre-Montaje Avanzado)

Si tu pedido incluye equipos, racks, conjuntos hidráulicos o salas técnicas confeccionados o configurados según tus especificaciones (uniones permanentes, cortes o cableado a medida, parametrización, pruebas de presión), estos son bienes personalizados sin derecho de desistimiento desde la celebración del contrato (art. 103.c TRLGDCU; STJUE C-529/19), lo que se informa antes de comprar y se documenta en la Nota de Encargo firmada. Una prueba que solicites sin modificación permanente conserva tu desistimiento, deduciéndose solo la pérdida real de valor que esa prueba cause. ¿Prefieres recibirlo probado, configurado y listo para conectar, sin asumir estos riesgos? Contrata el Pre-Montaje Avanzado o la auditoría técnica previa.

Si compras como empresa o profesional (B2B)

La operación se rige por el Código de Comercio: venta en firme, sin derecho de desistimiento; denuncia de vicios en 4 días (aparentes) / 30 días (ocultos), arts. 336 y 342. Q-TECH interviene como distribuidor y excluye los daños indirectos, el lucro cesante y la pérdida de datos, con el límite del precio del equipo, sin perjuicio de la garantía comercial del fabricante.

Advertencias de producto v1.0 · junio de 2026. Resumen informativo; las condiciones completas y vinculantes son las publicadas en q-tech.es.

Permanent refill station that tops up your heating system with demineralised water to VDI 2035

The magnetic NF plus fits in the filling line of the boiler or heat pump and supplies demineralised water at every top-up, with no mains power. Q-Tech integrates it into the pre-assembled plant room together with the backflow preventer, the water meter and the shut-off valves. Price on request: message us on WhatsApp and we will send you a quote.

Summary

TypeRefill station for demineralised water with mixed bed resin
Brand and modelmagnetic NF plus: NF 2, NF 6, NF 12 and NF 25 plus
UseTopping up closed heating and cooling circuits to VDI 2035
Capacity at 20 °dH225, 500, 1,200 or 2,400 litres depending on the model
Maximum flow rate300 to 1,500 litres per hour at 3 to 4 bar inlet pressure
ConnectionTwo G ¾ male threads (DN 20)
Power supplyNo mains power; the meter runs on three AAA batteries
Q-Tech installationAssembled and tested in the pre-assembled plant room or connected on-site by an Expert Technician

What is the magnetic NF plus?

The magnetic NF plus from magnetic is a permanent refill station for closed heating circuits that removes lime and salts from mains water with mixed bed resin. The water flows through the vessel and leaves demineralised. It mounts on the wall or stands on the floor, between the water supply and the system.

Conductivity meter and water counter

A battery-powered meter shows conductivity in µS per cm, flow rate and total litres. You set a limit and the meter checks the water every 20 litres: it warns when the resin is exhausted with a red light and an audible alarm. The resin is changed on site and the used resin goes in household waste, according to magnetic.

What problem does it solve?

A system with a buffer tank and underfloor heating easily exceeds more than 40 litres per kW, and in that case VDI 2035 calls for demineralised water. Every top-up with mains water adds lime, salts and oxygen. Mains water in Málaga city is fairly soft, about 10 °fH according to EMASA (2021), but it has hundreds of µS per cm and leaves the system in salt-containing operation, the most demanding on oxygen.

Topping up untreated water builds up lime in the heat exchanger and speeds up corrosion in pumps, valves and radiators. magnetic warns that topping up with mains water can void the heat generator warranty and worsen heat transfer. Many heat pump and boiler manufacturers refer to VDI 2035 in their manuals.

Technical data

TreatmentDemineralisation by ion exchange with premium mixed bed resin
Maximum filling temperature60 °C
Maximum pressure6 bar
Connections2 G ¾ male threads (DN 20)
MeterConductivity in µS per cm or ppm, flow rate and total litres, with adjustable limit and visual and audible alarm
Meter power supply3 AAA alkaline batteries
Vessel NF 2 and NF 6 plusFibre-reinforced plastic, screw-off, wall bracket included
Vessel NF 12 and NF 25 plusStainless steel with clamp lid and frost-protection drain, 170 mm diameter
OutletTwin shut-off valves and safety strainer that holds back the resin

Models and data by variant

ModelReferenceResinCapacity at 1 °dHCapacity at 20 °dHMaximum flow rateHeightOperating weight
NF 2 plus888 3012.7 l4,500 l225 l300 l per hour460 mm6.6 kg
NF 6 plus888 3056.5 l10,000 l500 l420 l per hour560 mm9.4 kg
NF 12 plus888 31112.5 l24,000 l1,200 l1,000 l per hour1,022 mm23 kg
NF 25 plus888 32125 l48,000 l2,400 l1,500 l per hour1,490 mm53.5 kg

Data from the magnetic technical data sheets (08-2021 and 04-2022). Up to 2,400 litres at 20 °dH per charge with the NF 25 plus.

Compatibility and limits

  • For closed heating and cooling circuits only; the treated water is not suitable for drinking.
  • A permanent connection to the drinking water network requires a BA backflow preventer to EN 1717 upstream of the station; magnetic supplies it as a separate accessory.
  • With automatic filling by solenoid valve, magnetic recommends a water hammer arrester: a sudden closure exceeds 6 bar.
  • Actual capacity drops if the mains water contains sulphates, nitrates or chlorides, because the resin removes them too.
  • Inlet temperature up to 60 °C and pressure up to 6 bar.

When this product is not the right choice

SituationWhat to chooseDeciding factor
Occasional small top-upsmagnetic demineralisation cartridge 300, disposable with colour indicator300 litres at 10 °dH per cartridge
First filling of a large systemMobile filling station or filling service with demineralised waterThe NF plus is designed for topping up, not for filling in one go
Oxygen, sludge or low pH with the water already in the systemmagnetic HWR plus heating water regulatorDegasses, filters sludge and stabilises pH in operation

Frequently asked questions

Which model do I need?

It depends on the litres you top up each year and on water hardness. magnetic suggests the NF 2 plus for up to 250 litres a year, the NF 6 up to 500, the NF 12 up to 2,500 and the NF 25 up to 10,000. Divide the capacity at 1 °dH by the hardness of your water to get the litres per charge.

What is the price?

On request. Message us on WhatsApp with the model and we will send you a quote.

What is the delivery time?

Made to order: we will confirm the lead time before preparing your order.

Do I need a backflow preventer?

Yes, for a permanent connection to the drinking water network. EN 1717 requires a type BA backflow preventer upstream of the station, sold separately.

How do I know the resin is exhausted?

The meter tells you. When conductivity exceeds the limit you set, it warns with a red light and an audible alarm.

Can I install it myself?

It is not advisable. A professional makes the connection to the mains and to the circuit, and magnetic states that permanent unsupervised use with a filling hose is not permitted.

Q-Tech installation and support

In a pre-assembled plant room, Q-Tech fits the NF plus with the BA backflow preventer, the meter and the valves, tests it in its workshop and the station arrives tested and ready to connect. More information on Pre-Montaje Avanzado.

In an existing system, Q-Tech first carries out a verification visit and then connects it with the on-site hourly Expert Technician. To choose the model, book a technical call. The guideline values are in our article VDI 2035: water quality in heat pump and heating systems and in the VDI 2035 calculator.

Q-Tech VDI 2035 calculator

Check whether the water in your heating system meets the VDI 2035 guideline (Part 1, 2021). Enter the output, the system volume in litres and the hardness and conductivity of your mains water: the calculator gives you the verdict and the three key figures for filling or topping up the circuit. If you need it, we will send you the full report.

Guidance only: check the manufacturer's requirements.

VDI 2035 calculator: check whether your system water meets the guideline. Open the calculator

Documentation

Availability and lead times: made to order. We will confirm the lead time before preparing your order.