Recambio Sonda pH CRISTAL para cloradores Hidrolife de Sugar Valley - Q-Tech ® 2026

CRISTAL BNC pH probe | Spare part for Sugar Valley and Hayward

Regular price€253,70
/
Shipping calculated at checkout.

  • In stock, ready to ship
  • Backordered, shipping soon

At Q-TECH, we apply the same clear rules for everyone: the law protects you, and when applied correctly, it protects us as well. By processing your purchase, you accept our General Terms and Conditions of Sale. If you are purchasing as a consumer (B2C), nothing stated herein limits the rights granted to you by mandatory law (RDL 1/2007, TRLGDCU): the 3-year legal warranty of conformity and the right of withdrawal under the terms and with the exceptions legally provided, which are detailed below. References to "B2B" apply only to businesses and professionals.

Your guarantees

  • Rights intact: 14 days of withdrawal from receipt for most products—subject to the legal exceptions you will see below, such as goods made to your specifications—and a 3-year legal warranty of conformity, under the terms of the TRLGDCU.
  • Conformity with the description: we guarantee that the equipment will correspond to the published technical description and what one could reasonably expect from it (arts. 115 et seq. TRLGDCU). Images and videos are for guidance only: the manufacturer may supply a more recent revision of the product or introduce minor aesthetic, packaging, or firmware changes, without this constituting a lack of conformity as long as the described characteristics and performance are maintained.
  • Traceability that also protects you: we document the condition, serial number, and seal of each piece of equipment upon shipment, and we video-record the opening of returns; this is your proof of the condition in which the goods were delivered.

Responsible use and your part

  • If you are thinking of returning it, keep it as you received it: without installing or activating it, with its seals, accessories, and packaging intact. This is how to ensure a full refund, without deductions.
  • Handling that exceeds inspection reduces value: handling the equipment beyond what is necessary to verify its nature and operation may result in a real, assessed, and case-by-case justified deduction (art. 108.2 TRLGDCU), never a fixed percentage. In particular: activating or registering the serial number, linking it to a manufacturer's account or app, circulating water through hydraulic equipment, unsealing probes, or installing software or consumables. Initial inspection of the product does not lead to a deduction.
  • The same item must be returned: withdrawal requires returning the supplied unit. Different equipment, or equipment with prior use, age, or wear prior to purchase, does not constitute a valid withdrawal.
  • Installation and cybersecurity, shared responsibility: this is technical hardware; you are responsible for correct installation, credentials, patches, and backups, while we deliver a compliant product. Q-TECH is not liable for damages resulting from poor installation, incorrect configuration, or omission of patches by the customer or third parties (in B2C, without prejudice to the legal warranty and liability for intent or negligence, arts. 86 and 130 TRLGDCU).
  • Delivery of bulky goods: delivery is made to the curb. B2C: transport risk is ours until physical delivery (art. 66 ter); we recommend noting visible damages on the delivery note and notifying us of breakages within 24-48 hours with photographs to activate the insurance. B2B: inspection and notation on the delivery note are mandatory; hidden damages must be reported within 24 hours (art. 366 CCom). Unjustified rejection or incorrect shipping information will entail the actual outbound and return costs (approx. €85-550 for heavy machinery).

Made to your measure (Advanced Pre-Assembly)

  • If your order includes equipment, racks, hydraulic assemblies, or technical rooms made or configured according to your specifications (permanent joints, custom cuts or wiring, parameterization, pressure testing), these are custom goods without the right of withdrawal from the conclusion of the contract (art. 103.c TRLGDCU; CJEU Case C-529/19), which is informed before purchasing and documented in the signed Order Note. A test you request without permanent modification retains your right of withdrawal, with only the actual loss of value caused by that test being deducted. Would you prefer to receive it tested, configured, and ready to connect, without assuming these risks? Contract our Advanced Pre-Assembly or the prior technical audit.

If you are purchasing as a business or professional (B2B)

  • The transaction is governed by the Commercial Code: firm sale, without the right of withdrawal; notification of defects within 4 days (apparent) / 30 days (hidden), arts. 336 and 342. Q-TECH acts as a distributor and excludes indirect damages, loss of profit, and data loss, limited to the price of the equipment, without prejudice to the manufacturer's commercial warranty.

Product warnings v1.0 · June 2026. Information summary; the complete and binding conditions are those published at q-tech.es.

You may also be interested in...

CRISTAL pH Probe: High-Fidelity Analytical Engineering

The CRISTAL pH Probe is a precision analytical component designed for constant water balance monitoring in advanced electrolysis systems. This electrode guarantees accurate pH readings, allowing the controller to execute efficient, proportional chemical corrections. The cost of inaction when using low-quality sensors includes erratic readings, acid overdosing, and accelerated deterioration of titanium electrodes. The CRISTAL pH Probe solves these operational risks through stable signal transmission and linear response to chemical variations.

Analytical Precision and Operational Stability

The CRISTAL pH Probe stands out for its measurement architecture designed for demanding water treatment environments. Its glass body ensures high-sensitivity monitoring and minimal calibration drift, optimizing technical facility maintenance.

  • High-Purity Glass Body: Manufactured from technical glass that allows for superior ionic transfer for laboratory-grade pH measurements.

  • Shielded Signal Transmission: The 2-meter cable minimizes electromagnetic interference, ensuring the equipment receives real and stable analytical data.

  • Industrial BNC Connector: Facilitates rapid, watertight integration with the controller, preventing signal loss due to moisture in electrical contacts.

  • Fast Dynamic Response: The sensitive membrane detects chemical changes in seconds, allowing for surgically precise dosing by the system.

Mechanical Robustness and Industrial Safety Standards

The manufacturing of the CRISTAL pH Probe follows high-level quality protocols for electrochemical instrumentation. Its design allows for fluid integration into standard probe holders, ensuring the hydraulic circuit remains watertight under constant flow conditions.

  • Multi-Platform Compatibility: Design validated for Sugar Valley (Hidrolife), Hayward, Kripsol, and Da-Gen systems, ensuring a perfect fit.

  • Easy Analytical Calibration: Optimized for perfect synchronization with pH buffer solutions, reducing system control adjustment time.

  • Sensitive Element Protection: The structural design protects the glass bulb during insertion into the installation's bypass.

  • System Sustainability: By maintaining a balanced pH, the probe contributes to the longevity of the water infrastructure and the biocidal efficacy of disinfectants.

Compatibility and Application Limits

The CRISTAL pH Probe is compatible with all controllers using a standard BNC input. It must be installed in a vertical or oblique electrode holder, always before the injection of chemical products to avoid damage from direct acid concentration. TECHNICAL RESTRICTION: Do not allow the sensor tip to dry out; it must always be submerged in fluid or storage solution. Do not use in applications with pressures exceeding 1.5 bar, and do not expose to sub-zero temperatures to avoid breakage of the glass body.

Frequently Asked Questions

  • Why choose a glass probe over a plastic one? The CRISTAL pH Probe offers superior analytical sensitivity. Technical glass allows for more stable and precise ionic exchange, resulting in a measurement that is more reliable and less prone to reading errors caused by material fatigue.

  • Is this probe compatible with my Hidrolife salt chlorinator? Absolutely. This probe is the specific replacement for equipment in the Sugar Valley range, including the Hidrolife model. Its BNC connector and 2-meter length ensure immediate integration with the equipment's motherboard.

  • How should I maintain the probe during the winter? Never let the probe dry out when out of the water. If you stop the system, you must store it in its original cap filled with storage solution (KCL). Proper maintenance ensures that the probe is ready to measure accurately the following season.

Q-Tech Engineering Support

At Q-tech.es, we provide specialized technical assistance for configuring high-fidelity analytical instrumentation. If you require support for calibration or in-person technical assistance for your CRISTAL pH Probe, contact our field engineers by phone or in person.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.