Electrodo Basic Sel Clear 7 placas AstralPool - Q-Tech ®
Electrodo Basic Sel Clear 7 placas AstralPool - Q-Tech ®
Electrodo Basic Sel Clear 7 placas AstralPool - Q-Tech ®
Electrodo Basic Sel Clear 7 placas AstralPool - Q-Tech ®
Electrodo Basic Sel Clear 7 placas AstralPool - Q-Tech ®

AstralPool Sel Clear 7-plate Basic Electrode

Model
Regular price€729,24
/
Shipping calculated at checkout.

  • In stock, ready to ship
  • Backordered, shipping soon

At Q-TECH, we apply the same clear rules for everyone: the law protects you, and when applied correctly, it protects us as well. By processing your purchase, you accept our General Terms and Conditions of Sale. If you are purchasing as a consumer (B2C), nothing stated herein limits the rights granted to you by mandatory law (RDL 1/2007, TRLGDCU): the 3-year legal warranty of conformity and the right of withdrawal under the terms and with the exceptions legally provided, which are detailed below. References to "B2B" apply only to businesses and professionals.

Your guarantees

  • Rights intact: 14 days of withdrawal from receipt for most products—subject to the legal exceptions you will see below, such as goods made to your specifications—and a 3-year legal warranty of conformity, under the terms of the TRLGDCU.
  • Conformity with the description: we guarantee that the equipment will correspond to the published technical description and what one could reasonably expect from it (arts. 115 et seq. TRLGDCU). Images and videos are for guidance only: the manufacturer may supply a more recent revision of the product or introduce minor aesthetic, packaging, or firmware changes, without this constituting a lack of conformity as long as the described characteristics and performance are maintained.
  • Traceability that also protects you: we document the condition, serial number, and seal of each piece of equipment upon shipment, and we video-record the opening of returns; this is your proof of the condition in which the goods were delivered.

Responsible use and your part

  • If you are thinking of returning it, keep it as you received it: without installing or activating it, with its seals, accessories, and packaging intact. This is how to ensure a full refund, without deductions.
  • Handling that exceeds inspection reduces value: handling the equipment beyond what is necessary to verify its nature and operation may result in a real, assessed, and case-by-case justified deduction (art. 108.2 TRLGDCU), never a fixed percentage. In particular: activating or registering the serial number, linking it to a manufacturer's account or app, circulating water through hydraulic equipment, unsealing probes, or installing software or consumables. Initial inspection of the product does not lead to a deduction.
  • The same item must be returned: withdrawal requires returning the supplied unit. Different equipment, or equipment with prior use, age, or wear prior to purchase, does not constitute a valid withdrawal.
  • Installation and cybersecurity, shared responsibility: this is technical hardware; you are responsible for correct installation, credentials, patches, and backups, while we deliver a compliant product. Q-TECH is not liable for damages resulting from poor installation, incorrect configuration, or omission of patches by the customer or third parties (in B2C, without prejudice to the legal warranty and liability for intent or negligence, arts. 86 and 130 TRLGDCU).
  • Delivery of bulky goods: delivery is made to the curb. B2C: transport risk is ours until physical delivery (art. 66 ter); we recommend noting visible damages on the delivery note and notifying us of breakages within 24-48 hours with photographs to activate the insurance. B2B: inspection and notation on the delivery note are mandatory; hidden damages must be reported within 24 hours (art. 366 CCom). Unjustified rejection or incorrect shipping information will entail the actual outbound and return costs (approx. €85-550 for heavy machinery).

Made to your measure (Advanced Pre-Assembly)

  • If your order includes equipment, racks, hydraulic assemblies, or technical rooms made or configured according to your specifications (permanent joints, custom cuts or wiring, parameterization, pressure testing), these are custom goods without the right of withdrawal from the conclusion of the contract (art. 103.c TRLGDCU; CJEU Case C-529/19), which is informed before purchasing and documented in the signed Order Note. A test you request without permanent modification retains your right of withdrawal, with only the actual loss of value caused by that test being deducted. Would you prefer to receive it tested, configured, and ready to connect, without assuming these risks? Contract our Advanced Pre-Assembly or the prior technical audit.

If you are purchasing as a business or professional (B2B)

  • The transaction is governed by the Commercial Code: firm sale, without the right of withdrawal; notification of defects within 4 days (apparent) / 30 days (hidden), arts. 336 and 342. Q-TECH acts as a distributor and excludes indirect damages, loss of profit, and data loss, limited to the price of the equipment, without prejudice to the manufacturer's commercial warranty.

Product warnings v1.0 · June 2026. Information summary; the complete and binding conditions are those published at q-tech.es.

You may also be interested in...

AstralPool Basic Sel Clear 7-Plate: Original Salt Electrolysis Engineering

The AstralPool Basic Sel Clear 7-plate electrode is the original disinfection component designed for Basic Sel and Sel Clear salt chlorination systems. This electrode uses high-purity titanium plates to transform sodium chloride into active chlorine consistently and efficiently. The cost of inaction when using compatible electrodes results in poor disinfection and potential failures in the unit's power board. The AstralPool Basic Sel Clear ensures stable chlorine production, protecting the health of users and the service life of the electronic controller.

Operational Efficiency and Polarity Reversal Self-Cleaning

The 7-plate AstralPool Basic Sel Clear optimizes the electrolysis process through a contact surface area calculated for systems up to 55 m3. The original design ensures that electrical resistance remains within the manufacturer's nominal parameters.

  • Reinforced Titanium Plates: The precious metal coating maximizes electron transfer and reduces premature electrode wear.

  • Self-Cleaning Technology: The plate architecture is compatible with polarity reversal cycles, automatically eliminating limescale deposits.

  • Constant Chlorine Production: Generates up to 13 g/h of free chlorine, ensuring crystal-clear water even under high organic load conditions.

  • Precision Installation: The body design and connection terminals ensure a watertight fit that prevents hydraulic leaks and electrical corrosion.

  • Original AstralPool electrode replacement for salt chlorinators of the Astral Sel Basic, Sel Clear, and Energy Sel series.

  • Available in 3 models:

    • For Astral Sel Basic / Sel Clear / Energy Sel 30: 54051 (former ref. 4408060203)
    • For Astral Sel Basic / Sel Clear / Energy Sel 55: 54052 (former ref. 4408060204)
    • For Astral Sel Basic / Sel Clear / Energy Sel 95: 54053 (former ref. 4408060205)

Mechanical Robustness and Industrial Safety Standards

The manufacturing of the Basic Sel Clear Electrode follows Fluidra's quality protocols. Its structure facilitates quick replacement in the technical room, reducing downtime in residential and commercial installations.

  • Chemically Resistant Body: The support materials withstand direct injection of pH correctors and elevated water flow temperatures.

  • Protected Connection Terminals: The design prevents overheating at contact points, protecting the control equipment wiring.

  • Factory Certification: Each unit is verified to meet the chlorine production curve specified for the Basic range models.

  • System Sustainability: By maintaining optimal conductivity, the system consumes less energy to generate the necessary oxidation potential.

Compatibility and Application Limits

The Basic Sel Clear 7-plate electrode is compatible exclusively with AstralPool Basic series salt chlorinators designed for 7 plates. It must be installed after the filter and before any additional heating or chemical dosing systems.

TECHNICAL RESTRICTION: Do not clean the plates with metal objects or concentrated acid solutions (maximum 10%). Do not operate with salinity below 3 g/L, as this causes accelerated wear of the titanium coating and voiding of the warranty.

Frequently Asked Questions

  • Why should I choose the original AstralPool electrode? The original AstralPool Basic Sel Clear electrode ensures correct communication with the electronic board. Compatible models often cause erroneous salt readings and have up to 50% shorter service life due to low titanium quality.

  • When is it necessary to change my chlorinator's electrode? You should replace it when chlorine production is insufficient despite having correct salt levels (approx. 4 g/L). If the plates show visible wear or the equipment indicates a lack of production after cleaning, the electrode has exhausted its chemical capacity.

  • How can I extend the life of my 7-plate cell? Maintain the water pH between 7.2 and 7.4. Uncontrolled pH forces the cell to work more hours to keep the water disinfected, which accelerates wear on the noble metal coating of the Basic Sel Clear plates.

Q-Tech Engineering Support

At Q-tech.es, we provide specialized technical assistance for optimizing water treatment systems. If you need to validate the compatibility of the AstralPool Basic Sel Clear or require on-site support for commissioning, please contact our field engineers.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Related products