Bomba de dosificación por tiempo de Avady TEMPO UV - Q-Tech ®

Avady TEMPO UV time-based dosing pump

Regular price €448,40 Sale price€341,02
/
Shipping calculated at checkout.

  • In stock, ready to ship
  • Backordered, shipping soon

At Q-TECH, we apply the same clear rules for everyone: the law protects you, and when applied correctly, it protects us as well. By processing your purchase, you accept our General Terms and Conditions of Sale. If you are purchasing as a consumer (B2C), nothing stated herein limits the rights granted to you by mandatory law (RDL 1/2007, TRLGDCU): the 3-year legal warranty of conformity and the right of withdrawal under the terms and with the exceptions legally provided, which are detailed below. References to "B2B" apply only to businesses and professionals.

Your guarantees

  • Rights intact: 14 days of withdrawal from receipt for most products—subject to the legal exceptions you will see below, such as goods made to your specifications—and a 3-year legal warranty of conformity, under the terms of the TRLGDCU.
  • Conformity with the description: we guarantee that the equipment will correspond to the published technical description and what one could reasonably expect from it (arts. 115 et seq. TRLGDCU). Images and videos are for guidance only: the manufacturer may supply a more recent revision of the product or introduce minor aesthetic, packaging, or firmware changes, without this constituting a lack of conformity as long as the described characteristics and performance are maintained.
  • Traceability that also protects you: we document the condition, serial number, and seal of each piece of equipment upon shipment, and we video-record the opening of returns; this is your proof of the condition in which the goods were delivered.

Responsible use and your part

  • If you are thinking of returning it, keep it as you received it: without installing or activating it, with its seals, accessories, and packaging intact. This is how to ensure a full refund, without deductions.
  • Handling that exceeds inspection reduces value: handling the equipment beyond what is necessary to verify its nature and operation may result in a real, assessed, and case-by-case justified deduction (art. 108.2 TRLGDCU), never a fixed percentage. In particular: activating or registering the serial number, linking it to a manufacturer's account or app, circulating water through hydraulic equipment, unsealing probes, or installing software or consumables. Initial inspection of the product does not lead to a deduction.
  • The same item must be returned: withdrawal requires returning the supplied unit. Different equipment, or equipment with prior use, age, or wear prior to purchase, does not constitute a valid withdrawal.
  • Installation and cybersecurity, shared responsibility: this is technical hardware; you are responsible for correct installation, credentials, patches, and backups, while we deliver a compliant product. Q-TECH is not liable for damages resulting from poor installation, incorrect configuration, or omission of patches by the customer or third parties (in B2C, without prejudice to the legal warranty and liability for intent or negligence, arts. 86 and 130 TRLGDCU).
  • Delivery of bulky goods: delivery is made to the curb. B2C: transport risk is ours until physical delivery (art. 66 ter); we recommend noting visible damages on the delivery note and notifying us of breakages within 24-48 hours with photographs to activate the insurance. B2B: inspection and notation on the delivery note are mandatory; hidden damages must be reported within 24 hours (art. 366 CCom). Unjustified rejection or incorrect shipping information will entail the actual outbound and return costs (approx. €85-550 for heavy machinery).

Made to your measure (Advanced Pre-Assembly)

  • If your order includes equipment, racks, hydraulic assemblies, or technical rooms made or configured according to your specifications (permanent joints, custom cuts or wiring, parameterization, pressure testing), these are custom goods without the right of withdrawal from the conclusion of the contract (art. 103.c TRLGDCU; CJEU Case C-529/19), which is informed before purchasing and documented in the signed Order Note. A test you request without permanent modification retains your right of withdrawal, with only the actual loss of value caused by that test being deducted. Would you prefer to receive it tested, configured, and ready to connect, without assuming these risks? Contract our Advanced Pre-Assembly or the prior technical audit.

If you are purchasing as a business or professional (B2B)

  • The transaction is governed by the Commercial Code: firm sale, without the right of withdrawal; notification of defects within 4 days (apparent) / 30 days (hidden), arts. 336 and 342. Q-TECH acts as a distributor and excludes indirect damages, loss of profit, and data loss, limited to the price of the equipment, without prejudice to the manufacturer's commercial warranty.

Product warnings v1.0 · June 2026. Information summary; the complete and binding conditions are those published at q-tech.es.

You may also be interested in...

Avady TEMPO UV: Timed Dosing Engineering for UV Systems

The Avady TEMPO UV is an intelligent dosing pump designed to manage the injection of residual sanitizer in swimming pools treated with ultraviolet lamps. This advanced engineering equipment allows for the scheduling of daily dosing cycles with second-level precision, ensuring water biosafety.

The cost of inaction in UV disinfection systems includes algae proliferation on walls and a lack of residual disinfectant in the pool vessel. The Avady TEMPO UV solves these operational risks through programmed and constant injection, eliminating the need for manual intervention and protecting user health.

Digital Control and Critical Cycle Programming

The Avady TEMPO UV stands out for its simplified user interface and its fine-tuning capability for dosing active oxygen or residual chlorine. The system ensures that disinfectant levels are maintained in the optimal range in an automated and reliable manner.

  • Backlit LCD Screen: High-contrast interface that allows for viewing the programming and pump status in low-light conditions.

  • Precise Daily Programming: The microprocessor allows the exact daily injection time to be defined, adjusting to the specific volume of the pool and the bathing load.

  • Industrial-Strength Housing: Manufactured from technical materials resistant to chemical vapors, complying with IP65 protection standards.

  • Automatic Priming: Dedicated function to facilitate initial startup and reagent replacement without the risk of air in the circuit.

Operational Safety and IT/OT Reliability

The architecture of the Avady TEMPO UV is designed for uninterrupted performance in high-level technical rooms. Its robust electronics protect the motor against electrical fluctuations and ensure a service life superior to basic dosing systems.

  • Intelligent Dosing Control: The equipment injects the exact programmed amount, optimizing chemical product consumption and reducing the facility's OPEX.

  • Level Sensor Input: Allows for the automatic shutdown of the equipment when the chemical tank is empty, protecting the peristaltic mechanism against dry running.

  • Peristaltic Maintenance: The head design allows for rapid replacement of the Santoprene tube without needing to remove the equipment from the technical wall.

  • Professional Installation Kit: Includes injection valve, suction filter, and connection tubes designed to withstand constant working pressures.

Technical Specifications

  • Dosing Flow: 1.5 l/h.

  • Maximum Pressure: 1.5 bar.

  • Protection Rating: IP65.

  • Screen Type: Backlit LCD.

  • Power Supply: 230V AC / 50-60 Hz.

  • Tube Material: High chemical compatibility Santoprene.

  • Operating Mode: Daily time programming (seconds/minutes).

Compatibility and Application Limits

The Avady TEMPO UV is compatible with ultraviolet treatment systems and disinfection using active oxygen or liquid chlorine. It must be installed on a vertical wall, always above the maximum level of the chemical product tank to avoid siphoning effects.

TECHNICAL RESTRICTION: Do not use with solid or viscous chemical products or those with suspended particles. The equipment requires a semi-annual inspection of the peristaltic tube to maintain dosing precision and prevent accidental leaks due to material fatigue.

Frequently Asked Questions

  • Why is the Avady TEMPO UV necessary if I already have an Ultraviolet system? UV systems disinfect the water passing through the chamber, but they do not leave residual disinfectant in the pool. The Avady TEMPO UV automatically injects the necessary dose of residual product to prevent algae from growing on the walls and corners of the vessel.

  • Is it difficult to program the pump for my pool? Not at all. The LCD menu is very intuitive. You only need to calculate the necessary injection time based on your pool's volume and program the daily start time. The system will repeat the cycle exactly every 24 hours.

  • What maintenance does the equipment require? Maintenance is minimal. You only need to periodically check that the chemical tank has product and change the internal pump tube once a year to ensure dosing is always precise and leak-free.

Q-Tech Engineering Support

At Q-tech.es, we provide specialized technical assistance for the integration of Avady control systems in critical environments. If you require support for programming or on-site technical assistance for your Avady TEMPO UV, contact our field engineers by phone or in person.

Documentation:

Download technical data sheet

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Related products