Domusa Ø60/100 coaxial horizontal outlet kit 1 m CGAS000375, catalogue drawing
Domusa Ø60/100 coaxial vertical outlet kit CGAS000380, catalogue drawing
Domusa Ø60/100 coaxial horizontal terminal 1 m CGAS000314
Domusa Ø60/100 coaxial 90° elbow CGAS000316 with clamp
Domusa Ø60/100 coaxial 45° elbow CGAS000317 with clamp
Domusa Ø60/100 coaxial pipe 1 m CGAS000318
Domusa Ø60/100 coaxial pipe 0.5 m CGAS000319
Domusa adapter from Ø80/80 twin pipe to Ø60/100 coaxial CGAS000399

Domusa Ø60/100 coaxial flue system for Avanttia NG: kits, pipes and elbows

Component
Regular price€90,49
/
Shipping calculated at checkout.

  • 2 in stock
  • Backordered, shipping soon

At Q-TECH, we apply the same clear rules for everyone: the law protects you, and when applied correctly, it protects us as well. By processing your purchase, you accept our General Terms and Conditions of Sale. If you are purchasing as a consumer (B2C), nothing stated herein limits the rights granted to you by mandatory law (RDL 1/2007, TRLGDCU): the 3-year legal warranty of conformity and the right of withdrawal under the terms and with the exceptions legally provided, which are detailed below. References to "B2B" apply only to businesses and professionals.

Your guarantees

  • Rights intact: 14 days of withdrawal from receipt for most products—subject to the legal exceptions you will see below, such as goods made to your specifications—and a 3-year legal warranty of conformity, under the terms of the TRLGDCU.
  • Conformity with the description: we guarantee that the equipment will correspond to the published technical description and what one could reasonably expect from it (arts. 115 et seq. TRLGDCU). Images and videos are for guidance only: the manufacturer may supply a more recent revision of the product or introduce minor aesthetic, packaging, or firmware changes, without this constituting a lack of conformity as long as the described characteristics and performance are maintained.
  • Traceability that also protects you: we document the condition, serial number, and seal of each piece of equipment upon shipment, and we video-record the opening of returns; this is your proof of the condition in which the goods were delivered.

Responsible use and your part

  • If you are thinking of returning it, keep it as you received it: without installing or activating it, with its seals, accessories, and packaging intact. This is how to ensure a full refund, without deductions.
  • Handling that exceeds inspection reduces value: handling the equipment beyond what is necessary to verify its nature and operation may result in a real, assessed, and case-by-case justified deduction (art. 108.2 TRLGDCU), never a fixed percentage. In particular: activating or registering the serial number, linking it to a manufacturer's account or app, circulating water through hydraulic equipment, unsealing probes, or installing software or consumables. Initial inspection of the product does not lead to a deduction.
  • The same item must be returned: withdrawal requires returning the supplied unit. Different equipment, or equipment with prior use, age, or wear prior to purchase, does not constitute a valid withdrawal.
  • Installation and cybersecurity, shared responsibility: this is technical hardware; you are responsible for correct installation, credentials, patches, and backups, while we deliver a compliant product. Q-TECH is not liable for damages resulting from poor installation, incorrect configuration, or omission of patches by the customer or third parties (in B2C, without prejudice to the legal warranty and liability for intent or negligence, arts. 86 and 130 TRLGDCU).
  • Delivery of bulky goods: delivery is made to the curb. B2C: transport risk is ours until physical delivery (art. 66 ter); we recommend noting visible damages on the delivery note and notifying us of breakages within 24-48 hours with photographs to activate the insurance. B2B: inspection and notation on the delivery note are mandatory; hidden damages must be reported within 24 hours (art. 366 CCom). Unjustified rejection or incorrect shipping information will entail the actual outbound and return costs (approx. €85-550 for heavy machinery).

Made to your measure (Advanced Pre-Assembly)

  • If your order includes equipment, racks, hydraulic assemblies, or technical rooms made or configured according to your specifications (permanent joints, custom cuts or wiring, parameterization, pressure testing), these are custom goods without the right of withdrawal from the conclusion of the contract (art. 103.c TRLGDCU; CJEU Case C-529/19), which is informed before purchasing and documented in the signed Order Note. A test you request without permanent modification retains your right of withdrawal, with only the actual loss of value caused by that test being deducted. Would you prefer to receive it tested, configured, and ready to connect, without assuming these risks? Contract our Advanced Pre-Assembly or the prior technical audit.

If you are purchasing as a business or professional (B2B)

  • The transaction is governed by the Commercial Code: firm sale, without the right of withdrawal; notification of defects within 4 days (apparent) / 30 days (hidden), arts. 336 and 342. Q-TECH acts as a distributor and excludes indirect damages, loss of profit, and data loss, limited to the price of the equipment, without prejudice to the manufacturer's commercial warranty.

Product warnings v1.0 · June 2026. Information summary; the complete and binding conditions are those published at q-tech.es.

Ø60/100 coaxial flue to vent the Avanttia NG boiler through a wall or the roof

The Domusa Ø60/100 coaxial flue brings together the kits, pipes and elbows that Domusa Teknik specifies for the Avanttia NG condensing boiler. Flue gases leave through the 60 mm inner pipe and combustion air enters through the 100 mm outer pipe.

Summary

Type Coaxial flue for gas condensing boiler
Brand and range Domusa Teknik, polypropylene flue accessories
Diameter Ø60/100 mm: flue gases through 60 mm, air through 100 mm
Maximum length 10 m horizontal (type C13) and 11 m vertical (type C33), according to Domusa
Compatible with Domusa Avanttia NG boilers; the Domusa price list also lists it for the Fusion Hybrid Gas Condens
Adapter The Avanttia NG leaves the factory set up for Ø80 twin pipes: a Ø60/100 coaxial flue needs adapter CGAS000399
Q-Tech installation Prepared from the pre-assembled plant room; the outdoor section, on-site by an Expert Technician

What is the Domusa Ø60/100 coaxial flue?

The Domusa Teknik Ø60/100 coaxial flue is a polypropylene flue system that exhausts flue gases and draws in air for the Avanttia NG boiler through a single duct. It is installed horizontally through an outside wall or vertically through the roof.

Models and data per variant

Component Domusa reference EAN
Horizontal outlet kit 1 m CGAS000375 8435134825953
Vertical outlet kit CGAS000380 8435134825960
Horizontal terminal 1 m CGAS000314 8435134825977
90° elbow CGAS000316 8435134825991
45° elbow CGAS000317 8435134826004
Pipe 1 m CGAS000318 8435134826011
Pipe 0.5 m CGAS000319 8435134826028
Adapter 80/80 to 60/100 CGAS000399 8435134851235

Compatibility and limits

  • For Domusa Avanttia NG boilers, according to the installation manual and the Domusa Teknik 2026 price list.
  • The Avanttia NG comes set up for Ø80 twin pipes. A Ø60/100 coaxial flue needs adapter CGAS000399, which Domusa supplies to order.
  • Maximum length: 10 m horizontal and 11 m vertical. Each 90° elbow counts as 1.3 m and each 45° elbow as 1.0 m.
  • Domusa specifies a 2° to 3° upward slope on the horizontal section so that no water or condensate is expelled outside.
  • Domusa requires its own accessories for the flue. On the roof, the flat or pitched roof flashing is sold separately.
  • Gas and flue installation is carried out by a licensed installation company.

Frequently asked questions

Which components do I need?

For a standard outlet, the horizontal or vertical kit plus adapter CGAS000399. For longer runs, add pipes and elbows without exceeding the maximum length; if in doubt, send us the route on WhatsApp.

Should I choose Ø60/100 or Ø80/125 coaxial?

It depends on the run. Ø60/100 reaches 10 m horizontally and Ø80/125 reaches 20 m, according to Domusa; for long runs, see the Ø80/125 coaxial flue.

Does it come with the boiler?

No. Domusa sells it separately, as an accessory for the Avanttia NG boiler.

What is the lead time?

It is in stock at our warehouse.

Documentation

Availability and lead times: this item is in stock at our warehouse. Occasionally, depending on the time of year, the stock update may contain an error. If no units are available when you place your order, we will order it urgently and inform you immediately of the updated delivery time.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.