STRATOS de WILO - Q-Tech ®

WILO STRATOS

Model
Regular price €818,92 Sale price€706,82
/
Shipping calculated at checkout.

  • 2 in stock
  • Backordered, shipping soon

At Q-TECH, we apply the same clear rules for everyone: the law protects you, and when applied correctly, it protects us as well. By processing your purchase, you accept our General Terms and Conditions of Sale. If you are purchasing as a consumer (B2C), nothing stated herein limits the rights granted to you by mandatory law (RDL 1/2007, TRLGDCU): the 3-year legal warranty of conformity and the right of withdrawal under the terms and with the exceptions legally provided, which are detailed below. References to "B2B" apply only to businesses and professionals.

Your guarantees

  • Rights intact: 14 days of withdrawal from receipt for most products—subject to the legal exceptions you will see below, such as goods made to your specifications—and a 3-year legal warranty of conformity, under the terms of the TRLGDCU.
  • Conformity with the description: we guarantee that the equipment will correspond to the published technical description and what one could reasonably expect from it (arts. 115 et seq. TRLGDCU). Images and videos are for guidance only: the manufacturer may supply a more recent revision of the product or introduce minor aesthetic, packaging, or firmware changes, without this constituting a lack of conformity as long as the described characteristics and performance are maintained.
  • Traceability that also protects you: we document the condition, serial number, and seal of each piece of equipment upon shipment, and we video-record the opening of returns; this is your proof of the condition in which the goods were delivered.

Responsible use and your part

  • If you are thinking of returning it, keep it as you received it: without installing or activating it, with its seals, accessories, and packaging intact. This is how to ensure a full refund, without deductions.
  • Handling that exceeds inspection reduces value: handling the equipment beyond what is necessary to verify its nature and operation may result in a real, assessed, and case-by-case justified deduction (art. 108.2 TRLGDCU), never a fixed percentage. In particular: activating or registering the serial number, linking it to a manufacturer's account or app, circulating water through hydraulic equipment, unsealing probes, or installing software or consumables. Initial inspection of the product does not lead to a deduction.
  • The same item must be returned: withdrawal requires returning the supplied unit. Different equipment, or equipment with prior use, age, or wear prior to purchase, does not constitute a valid withdrawal.
  • Installation and cybersecurity, shared responsibility: this is technical hardware; you are responsible for correct installation, credentials, patches, and backups, while we deliver a compliant product. Q-TECH is not liable for damages resulting from poor installation, incorrect configuration, or omission of patches by the customer or third parties (in B2C, without prejudice to the legal warranty and liability for intent or negligence, arts. 86 and 130 TRLGDCU).
  • Delivery of bulky goods: delivery is made to the curb. B2C: transport risk is ours until physical delivery (art. 66 ter); we recommend noting visible damages on the delivery note and notifying us of breakages within 24-48 hours with photographs to activate the insurance. B2B: inspection and notation on the delivery note are mandatory; hidden damages must be reported within 24 hours (art. 366 CCom). Unjustified rejection or incorrect shipping information will entail the actual outbound and return costs (approx. €85-550 for heavy machinery).

Made to your measure (Advanced Pre-Assembly)

  • If your order includes equipment, racks, hydraulic assemblies, or technical rooms made or configured according to your specifications (permanent joints, custom cuts or wiring, parameterization, pressure testing), these are custom goods without the right of withdrawal from the conclusion of the contract (art. 103.c TRLGDCU; CJEU Case C-529/19), which is informed before purchasing and documented in the signed Order Note. A test you request without permanent modification retains your right of withdrawal, with only the actual loss of value caused by that test being deducted. Would you prefer to receive it tested, configured, and ready to connect, without assuming these risks? Contract our Advanced Pre-Assembly or the prior technical audit.

If you are purchasing as a business or professional (B2B)

  • The transaction is governed by the Commercial Code: firm sale, without the right of withdrawal; notification of defects within 4 days (apparent) / 30 days (hidden), arts. 336 and 342. Q-TECH acts as a distributor and excludes indirect damages, loss of profit, and data loss, limited to the price of the equipment, without prejudice to the manufacturer's commercial warranty.

Product warnings v1.0 · June 2026. Information summary; the complete and binding conditions are those published at q-tech.es.

You may also be interested in...

* Models with PN10 threaded connection. Other models, please consult.

Special features

  • Energy savings due to superior system efficiency with Q-Limit function (flow limitation)
  • Improved Energy Efficiency Index (EEI) ≤0.20 for all single pumps
  • Optimized display for better readability and operation
  • Installation in confined spaces thanks to compact design and freely positionable liquid crystal display
  • Modular concept for linking to all conventional bus systems (e.g., Modbus, BACnet, CAN, LON, PLR)
  • Guaranteed quality and reliability

Type

Glandless circulator pump with threaded or flanged connection, EC motor with automatic power adjustment

Application

All hot water heating systems, air conditioning installations, closed cooling circuits, and industrial circulation systems.

Function

Manual functions

  • Operating mode setting
  • Differential pressure setpoint adjustment
  • Automatic setback mode adjustment
  • Pump ON/OFF adjustment
  • Speed adjustment (manual mode)

Automatic functions

  • Continuous power adjustment depending on the operating mode
  • Automatic setback mode
  • Unblocking function
  • Soft start
  • Integrated full motor protection with trip electronics

External control functions

  • "Priority OFF" control input (possible with IF Stratos modules)
  • "Priority min." control input (possible with IF Stratos modules)
  • "Analog 0-10 V" control input (remote speed control) (possible with IF Stratos modules)
  • "Analog 0-10 V" control input (remote setpoint adjustment) (requires IF Stratos modules)

Indication and warning functions

  • General fault signal (potential-free NC contact)
  • Individual operation signal (potential-free NO contact) (requires IF Stratos modules)
  • Fault signal lamp
  • LCD display for pump data and error codes

Data exchange

  • Infrared interface for wireless data exchange with IR-Stick/IR-Monitor
  • Modbus RTU digital serial interface for connection to Building Automation (BA) via an RS485 BUS system (possible with IF Stratos modules).
  • BACnet MS/TP slave digital serial interface for connection to Building Automation (BA) via an RS485 BUS system (possible with IF Stratos modules).
  • CAN Modbus digital serial interface for connection to Building Automation (BA) via a CAN BUS system (possible with IF Stratos modules).
  • LON digital serial interface for connection to a LONWorks network (possible with IF Stratos modules)
  • PLR digital serial interface for connection to Building Automation (BA) via Wilo interface converters or company-specific coupling modules (possible with IF Stratos modules)

Dual pump management (twin pump or 2 single pumps)

  • Main/standby operation (automatic fault-actuated switchover/time-dependent pump cycling): various combinations possible with IF Stratos modules (accessories)
  • Parallel operation (efficiency-optimized peak-load activation and deactivation): various combinations possible with IF Stratos modules (accessories)

Scope of delivery

  • Pump
  • Incl. thermal insulation
  • Incl. seals for threaded connection
  • Incl. washers for flange bolts (for nominal connection diameters DN 32 - DN 65)
  • Incl. installation and operating manual

Technical data

  • Permissible temperature range from -10 °C to +110 °C
  • Mains connection 1~230 V, 50/60 Hz
  • Protection class IP X4D
  • Threaded or flanged connection (depending on type) Rp 1 to DN 100
  • Max. operating pressure of the standard version: 6/10 bar and 6 bar (special version: 10 bar or 16 bar)

Materials

  • Pump housing: Cast iron with cataphoretic coating
  • Thermal insulation: Polypropylene
  • Shaft: Stainless steel
  • Bearing: Carbon, metal-impregnated
  • Impeller: Plastic

Description

  • Glandless circulator pump with EC motor and integrated automatic power adjustment
  • Red Button technology and graphic display
  • Motor protection with trip electronics
  • Plug connection for function expansion with optional IF modules for Building Automation (BA)
  • Impeller with 3D-angled blades and carbon-fiber-reinforced composite shroud

Documentation

Download Wilo Stratos technical manual

      This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.