Bomba circuladora doble DAB EVOPLUS Small D con bridas y dos cabezales con pantalla
Familia de bombas circuladoras DAB EVOPLUS de nuevo diseño, simples y dobles

DAB EVOPLUS Small D flanged twin circulator pump for heating

Model
Regular price€2.043,18
/
Tax included. Shipping calculated at checkout.

  • 3 in stock
  • Backordered, shipping soon

At Q-TECH, we apply the same clear rules for everyone: the law protects you, and when applied correctly, it protects us as well. By processing your purchase, you accept our General Terms and Conditions of Sale. If you are purchasing as a consumer (B2C), nothing stated herein limits the rights granted to you by mandatory law (RDL 1/2007, TRLGDCU): the 3-year legal warranty of conformity and the right of withdrawal under the terms and with the exceptions legally provided, which are detailed below. References to "B2B" apply only to businesses and professionals.

Your guarantees

  • Rights intact: 14 days of withdrawal from receipt for most products—subject to the legal exceptions you will see below, such as goods made to your specifications—and a 3-year legal warranty of conformity, under the terms of the TRLGDCU.
  • Conformity with the description: we guarantee that the equipment will correspond to the published technical description and what one could reasonably expect from it (arts. 115 et seq. TRLGDCU). Images and videos are for guidance only: the manufacturer may supply a more recent revision of the product or introduce minor aesthetic, packaging, or firmware changes, without this constituting a lack of conformity as long as the described characteristics and performance are maintained.
  • Traceability that also protects you: we document the condition, serial number, and seal of each piece of equipment upon shipment, and we video-record the opening of returns; this is your proof of the condition in which the goods were delivered.

Responsible use and your part

  • If you are thinking of returning it, keep it as you received it: without installing or activating it, with its seals, accessories, and packaging intact. This is how to ensure a full refund, without deductions.
  • Handling that exceeds inspection reduces value: handling the equipment beyond what is necessary to verify its nature and operation may result in a real, assessed, and case-by-case justified deduction (art. 108.2 TRLGDCU), never a fixed percentage. In particular: activating or registering the serial number, linking it to a manufacturer's account or app, circulating water through hydraulic equipment, unsealing probes, or installing software or consumables. Initial inspection of the product does not lead to a deduction.
  • The same item must be returned: withdrawal requires returning the supplied unit. Different equipment, or equipment with prior use, age, or wear prior to purchase, does not constitute a valid withdrawal.
  • Installation and cybersecurity, shared responsibility: this is technical hardware; you are responsible for correct installation, credentials, patches, and backups, while we deliver a compliant product. Q-TECH is not liable for damages resulting from poor installation, incorrect configuration, or omission of patches by the customer or third parties (in B2C, without prejudice to the legal warranty and liability for intent or negligence, arts. 86 and 130 TRLGDCU).
  • Delivery of bulky goods: delivery is made to the curb. B2C: transport risk is ours until physical delivery (art. 66 ter); we recommend noting visible damages on the delivery note and notifying us of breakages within 24-48 hours with photographs to activate the insurance. B2B: inspection and notation on the delivery note are mandatory; hidden damages must be reported within 24 hours (art. 366 CCom). Unjustified rejection or incorrect shipping information will entail the actual outbound and return costs (approx. €85-550 for heavy machinery).

Made to your measure (Advanced Pre-Assembly)

  • If your order includes equipment, racks, hydraulic assemblies, or technical rooms made or configured according to your specifications (permanent joints, custom cuts or wiring, parameterization, pressure testing), these are custom goods without the right of withdrawal from the conclusion of the contract (art. 103.c TRLGDCU; CJEU Case C-529/19), which is informed before purchasing and documented in the signed Order Note. A test you request without permanent modification retains your right of withdrawal, with only the actual loss of value caused by that test being deducted. Would you prefer to receive it tested, configured, and ready to connect, without assuming these risks? Contract our Advanced Pre-Assembly or the prior technical audit.

If you are purchasing as a business or professional (B2B)

  • The transaction is governed by the Commercial Code: firm sale, without the right of withdrawal; notification of defects within 4 days (apparent) / 30 days (hidden), arts. 336 and 342. Q-TECH acts as a distributor and excludes indirect damages, loss of profit, and data loss, limited to the price of the equipment, without prejudice to the manufacturer's commercial warranty.

Product warnings v1.0 · June 2026. Information summary; the complete and binding conditions are those published at q-tech.es.

You may also be interested in...

Electronic twin circulator pump with flanges for heating and cooling in buildings

The DAB EVOPLUS Small D is the twin version of the EVOPLUS Small: two electronic motors in one pump body with DN32 or DN40 flanges. It moves water in heating or cooling systems in buildings with up to 11.2 m head and keeps one motor in reserve. At Q-Tech we fit it in pre-assembled plant rooms.

Summary

TypeWet-rotor electronic twin circulator pump with display
Brand and modelDAB EVOPLUS Small D, flanged (220 and 250 mm)
UseHeating, air conditioning and cooling in residential and commercial buildings
Maximum head4.2, 6.1, 8 or 11.2 m depending on size
FlowRange of 2 to 12 m³ per hour depending on model
Compatible withClean water or water with up to 30% glycol
Power supplySingle-phase 230 V, 50 or 60 Hz; 70 to 190 W maximum depending on size
Q-Tech installationFitted in a pre-assembled plant room or replaced on site by an Expert Technician

What is the DAB EVOPLUS Small D?

It is the EVOPLUS Small in DAB's new design (November 2026 catalogue) as a twin pump. It has two permanent-magnet synchronous motors with inverters on a shared cast-iron body, a flap valve on the outlet and a blanking flange.

What problem does it solve?

In a building, if the only heating pump stops, the whole system is out of service until it is repaired.

With the EVOPLUS Small D there is a second motor in the same body. The flap valve stops water flowing back through the idle motor, and the blanking flange lets you remove one head and close its opening. Each motor regulates by differential pressure, like the EVOPLUS Small.

Technical data

Liquid temperature−10 to +110 °C
Maximum pressure16 bar
Protection and insulationIP44 · class F
Control modesProportional differential pressure (factory setting), constant differential pressure and constant curve; temperature control and Economy mode with optional module
DisplayHead, flow, speed, power and running hours on each motor
Communication0-10 V and PWM inputs and Modbus with optional modules; compatible with D.Connect (D.Connect Box sold separately)
MaterialsCast-iron body, aluminium motor housing, technopolymer impeller, alumina shaft on graphite bearings, stainless steel rotor liner
IncludedFlap valve on the outlet and blanking flange
MountingMotor shaft horizontal

Models and data by variant

ModelConnectionFlange-to-flangeMax. headMax. power per motorDAB codeNet weight
D 40/220.32DN32 PN6 flanges220 mm4.2 m70 W6023136713.5 kg
D 60/220.32DN32 PN6 flanges220 mm6.1 m95 W6023136813.5 kg
D 80/220.32DN32 PN6 flanges220 mm8 m130 W6022093513.5 kg
D 110/220.32DN32 PN6 flanges220 mm11.2 m190 W6023137013.5 kg
D 40/250.40DN40 PN10 flanges250 mm4.2 m75 W6023137114.2 kg
D 60/250.40DN40 PN10 flanges250 mm6.1 m100 W6022093614.2 kg
D 80/250.40DN40 PN10 flanges250 mm8 m135 W6023137314.2 kg
D 110/250.40DN40 PN10 flanges250 mm11.2 m190 W6023137414.2 kg

Codes from the DAB Ibérica November 2026 catalogue; they replace the 6015xxxx codes of the previous generation with the same dimensions.

Compatibility and limits

  • Counter-flanges, gaskets and bolts not included: order them separately to suit your pipework.
  • Clean liquid, free of solids and mineral oils, with up to 30% glycol.
  • Mount with the motor shaft horizontal.
  • Not a domestic hot water pump.

When this product is not the right choice

ProductWhen to choose itMax. head
DAB EVOPLUS SmallYou do not need a reserve motor: single threaded or flanged pump4 to 11 m
DAB EVOPLUS Medium and LargeYou need more flow or DN32 to DN100 flanges4 to 18 m

Frequently asked questions

What do 220.32 and 250.40 mean?

The flange-to-flange length and the flange size: 220 mm with DN32 flanges or 250 mm with DN40 flanges.

Is the power in the table for both motors?

It is the maximum power of each motor, according to DAB.

What is the delivery time?

It is in stock at our warehouse; if none were left, we would order it urgently and tell you the lead time.

Who should install it?

Qualified professionals must make the plumbing and electrical connections.

Q-Tech installation and support

Q-Tech fits and tests the EVOPLUS Small D in our workshop as part of a pre-assembled plant room, which arrives tested and ready to connect. To replace a pump in your system, book an on-site Expert Technician by the hour; if you are unsure which model fits, request a technical call. More equipment in DAB circulator pumps.

Documentation

Availability and lead times: this item is in stock at our warehouse. Occasionally, depending on the time of year, the stock update may contain an error. If no units are available when you place your order, we will order it urgently and inform you immediately of the updated delivery time.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.