▪ Steps to follow to replace the battery of the Astral Blue Connect:
1. Under "Settings" » "Blue Connect", tap "Battery Change".
2. Remove the analyzer from the water, remove the rubber ring and the storage cap, and place Blue Connect in the storage cap.
3. Dry it and start the procedure in a clean, dry place.
4. Remove the adhesive tape and unscrew the top of the device. This is a left-hand thread. Unscrew clockwise. Remove the gasket and discard it.
5. Disconnect the white connector by pulling the red and black wires. The battery is located at the other end of the cable. Press the plastic rod to release the battery and remove it by pulling the cable.
6. Place the battery into the bottom of the cavity until it clicks into place. Then, connect the connector.
7. Place the new gasket supplied with the battery over the threads on the top of the unit. Close the top. This is a left-hand thread. Screw it counterclockwise.
8. Apply the new adhesive tape supplied with the battery and replace the ring. Then, replace the usage cap and return your Blue Connect to the water.