ESBE CRA111 Actuator and Controller (CRA110 Series) for Constant Flow Temperature
You may also be interested
You will soon find replacement parts for this product here.
He ESBE CRA111 It is a compact unit that combines a rotary actuator of 6Nm and a constant temperature controller. This device is designed to provide precise and automated flow control in heating systems, specifically when a stable (constant) supply temperature is required.
Its use is indispensable in applications of Underfloor heating, return temperature control or domestic hot water (DHW) circulation circuitsIt adapts the position of the mixing valve (VRG/VRB) in real time to compensate for fluctuations in the primary system. The adjustment is simple and intuitive thanks to its interface with a screen and joystick.
The integration of the CRA111 actuator with the ESBE valves ensures a Experience of superior control and a Trust maximum energy management.
This table distinguishes the critical characteristics of the CRA110 series.
| Feature | Technical Details |
| Function | Integrated Rotary Actuator and Controller |
| Nominal Torque | 6Nm |
| Operating Time | 30s at maximum speed (for 90º) |
| Valve Compatibility | ESBE Rotary Mixing Valves VRG, VRB and up to DN50 |
| Adjustable Temperature Range | 5ºC to 95ºC |
| Operating Ambient Temperature | -5ºC to 55ºC |
| Level of Protection | IP41 (Protected against solid objects &>1 mm and vertical dripping) |
| Sensor Included | Flow pipe probe with cable 1.5m |
| Electricity Consumption | 230 V AC: 10th / 24 V AC: 3 VA |
CRA111: 230V AC (Includes adapter/transformer)
CRA112: 24V AC
In underfloor heating systems, constant control is vital to prevent overheating of the floor surface, protecting the materials (parquet, tiles) and ensuring maximum comfort. The CRA111 regulates the water mixture so that the supply flow rate remains precisely at the design temperature (e.g., 35ºC).
The pair of 6Nm is sufficient to turn most ESBE VRG and VRB series mixing valves up to a nominal diameter (DN) of 50mmFor larger valves or high differential pressure systems, an actuator with higher torque should be considered.
Yes, it's essential. For the CRA111 to maintain reliable accuracy and temperature control, the flow probe must measure only the fluid temperature. The probe must be carefully isolated from ambient temperature to avoid false readings that could lead to incorrect valve regulation.
If you need to check the compatibility between the torque of the CRA111 and your existing mixing valve, or if you have questions about the correct installation and insulation of the probe, please contact our technical support team. Ensure proper installation with the Authority and Experience from an expert.