{"product_id":"modulo-temperatura-sugar-valley-control-filtracion-inteligente","title":"Temperature module for Sugar Valley equipment","description":"\u003ch3 data-path-to-node=\"6\"\u003eSugar Valley Temperature Module: Active Thermal Control Engineering\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-path-to-node=\"7\" data-index-in-node=\"3\"\u003eTemperature module for Sugar Valley equipment\u003c\/b\u003e is a thermal monitoring system designed to automate filtration based on water temperature. This equipment allows for the activation of smart management modes (Smart \/ Intelligent) to optimize electrical consumption and chemical efficiency. The cost of inaction when operating with fixed filtration times includes unnecessary energy expenditure in winter and insufficient disinfection in summer. The \u003cb data-path-to-node=\"7\" data-index-in-node=\"461\"\u003eSugar Valley Temperature Module\u003c\/b\u003e resolves these operational risks through IT\/OT control that adjusts work cycles to the actual thermal demand.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eIntelligent Automation and Climate Management\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-path-to-node=\"9\" data-index-in-node=\"3\"\u003eTemperature module for Sugar Valley equipment\u003c\/b\u003e stands out for its ability to integrate heating and filtration management into a single interface. Its electronic architecture allows for an immediate response to climate variations, extending the service life of treatment equipment.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eActive Temperature-Based Filtration:\u003c\/b\u003e Automatically adjusts the system's operating hours according to the water temperature in degrees Celsius, preventing algae proliferation.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eAdvanced Mode Control:\u003c\/b\u003e Enables \u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"51\"\u003eSmart\u003c\/b\u003e, \u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"58\"\u003eHeating\u003c\/b\u003e, and \u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"72\"\u003eIntelligent\u003c\/b\u003e functions on the chlorinator's motherboard for total energy management.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eHigh-Precision NTC Probe:\u003c\/b\u003e Uses an active temperature sensor with a \u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"82\"\u003e1\/2\"\u003c\/b\u003e thread for a stable reading without analytical drift.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eIntegrated Probe Holder:\u003c\/b\u003e Includes the infrastructure necessary for a watertight installation in the pipe, ensuring constant flow monitoring.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMechanical Robustness and Industrial Safety Standards\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003eThe manufacturing of the \u003cb data-path-to-node=\"12\" data-index-in-node=\"19\"\u003eTemperature module for Sugar Valley equipment\u003c\/b\u003e follows safety protocols for advanced hydraulic instrumentation. Its design allows for seamless integration into existing systems, ensuring operational continuity in demanding water treatment environments.\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eIndustrial-Grade Components:\u003c\/b\u003e Made with materials resistant to chemical corrosion and pressure variations in the hydraulic circuit.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eHigh-Fidelity Installation:\u003c\/b\u003e The \u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"56\"\u003e1\/2\"\u003c\/b\u003e probe design ensures precise insertion into the water flow for high-sensitivity measurements.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eComprehensive Technical Documentation:\u003c\/b\u003e Includes a detailed installation manual for professional installers, facilitating the configuration of thermal setpoint parameters.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eSystem Sustainability:\u003c\/b\u003e By optimizing filtration hours, the module reduces the installation's carbon footprint and decreases mechanical wear on the pump.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eSensor Type:\u003c\/b\u003e NTC active temperature probe.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eConnection Thread:\u003c\/b\u003e \u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"19\"\u003e1\/2\"\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eCompatible Modes:\u003c\/b\u003e Smart, Heating, and Intelligent.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eIncluded Infrastructure:\u003c\/b\u003e 1 temperature probe + 1 probe holder.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,4,0\"\u003e\u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"0\"\u003eFunction:\u003c\/b\u003e Temperature-based filtration control and heat management.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,5,0\"\u003e\u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"0\"\u003eCompatibility:\u003c\/b\u003e Full range of Sugar Valley equipment (Hidrolife, Oxilife, Bionet).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eCompatibility and Application Limits\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"17\"\u003eThe \u003cb data-path-to-node=\"17\" data-index-in-node=\"3\"\u003eTemperature module for Sugar Valley equipment\u003c\/b\u003e is compatible with all controllers in the Sugar Valley series and its licensed brands. It must be installed in the filtration circuit, preferably before any heating system to measure the actual pool water temperature. \u003cb data-path-to-node=\"17\" data-index-in-node=\"289\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not install in pipe sections without constant water circulation. The probe must be protected from temperatures exceeding \u003cb data-path-to-node=\"17\" data-index-in-node=\"432\"\u003e60 °C\u003c\/b\u003e and the tightness of the holder must be verified after installation to prevent leaks due to excessive pressure.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"0\"\u003eHow does this module help save energy in my pool?\u003c\/b\u003e The \u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"60\"\u003eTemperature module for Sugar Valley equipment\u003c\/b\u003e allows filtration to operate only for as long as necessary. In cold water, the system automatically reduces pumping hours, while in warm water it increases them to ensure disinfection, avoiding electrical waste.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"0\"\u003eIs this module necessary if I want to install a heat pump?\u003c\/b\u003e It is highly recommended. The module allows the Sugar Valley equipment to control the heat pump and manage filtration simultaneously. This ensures the heating only activates when there is water flow, protecting both systems and optimizing thermal performance.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"0\"\u003eCan it be installed on older equipment?\u003c\/b\u003e This module is designed for current Sugar Valley electronics. If your equipment has inputs for a temperature probe on the motherboard, integration is direct. Verify compatibility with your model's manual or consult our technical support.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"20\"\u003e\u003cb data-path-to-node=\"20\" data-index-in-node=\"0\"\u003eQ-Tech Engineering Support\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"21\"\u003eAt Q-tech.es, we provide specialized technical assistance for configuring energy efficiency protocols in Sugar Valley systems. If you require support for installation or on-site technical assistance for your \u003cb data-path-to-node=\"21\" data-index-in-node=\"228\"\u003eTemperature module for Sugar Valley equipment\u003c\/b\u003e, contact our field engineers by phone or in person.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003eDocumentation:\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener noreferrer\" title=\"Download Sugar Valley temperature control installation manual\" href=\"http:\/\/smartswim.net\/wp-content\/uploads\/2018\/03\/Probe_temperature-ES-EN-DE-FR.pdf\" target=\"_blank\"\u003eDownload installation manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Sugar Valley","offers":[{"title":"Default Title","offer_id":19971573645400,"sku":"PS-11501","price":79.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/sugar-valley-modulo-de-temperatura-para-equipos-sugar-valley-default-title-52965552882008.jpg?v=1702916136","url":"https:\/\/q-tech.es\/en\/products\/modulo-temperatura-sugar-valley-control-filtracion-inteligente","provider":"Q-Tech ® ","version":"1.0","type":"link"}