{"title":"Replacement cells and electrodes","description":"\u003cp class=\"qt-version\"\u003eFP54·261111\u003c\/p\u003e","products":[{"product_id":"celula-electrodo-zodiac-tri-expert-exo-iq-original","title":"Zodiac TRi and eXO iQ cell","description":"\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eZodiac TRi Cell: High-Fidelity Disinfection Engineering\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe \u003cb data-path-to-node=\"6\" data-index-in-node=\"3\"\u003eZodiac TRi Cell Electrode\u003c\/b\u003e is the power core for high-performance salt chlorination systems. This genuine spare part ensures consistent active chlorine production, maintaining water biosecurity in professional-grade residential and commercial installations.\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe cost of inaction when operating with a depleted cell includes pathogen proliferation, increased energy consumption, and the risk of overload damage to the equipment's power board. The \u003cb data-path-to-node=\"7\" data-index-in-node=\"202\"\u003eoriginal Zodiac TRi Cell\u003c\/b\u003e addresses these risks through titanium electrodes with a premium catalytic coating that optimizes hydrolysis.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eElectrodynamic Performance and Active Self-Cleaning\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-path-to-node=\"9\" data-index-in-node=\"3\"\u003eZodiac TRi Cell Electrode\u003c\/b\u003e stands out for its ability to maintain nominal performance under variable hydraulic conditions. Its plate architecture ensures efficient ionic transfer, allowing the chlorinator to always operate at its point of maximum efficiency.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003ePlug-and-Play Technical Replacement:\u003c\/b\u003e The design allows for direct replacement by the user or technician, minimizing downtime in the equipment room.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eIntelligent Anti-Scale Technology:\u003c\/b\u003e Uses an automatic \u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"54\"\u003epolarity reversal\u003c\/b\u003e system that eliminates limescale deposits, ensuring electrode longevity.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eIndustrial-Grade Materials:\u003c\/b\u003e Entirely manufactured in high-purity \u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"67\"\u003eTitanium\u003c\/b\u003e alloy for maximum reliability against chemical corrosion.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eProduction Scalability:\u003c\/b\u003e Available in four configurations of \u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"69\"\u003e10 g\/h\u003c\/b\u003e, \u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"77\"\u003e18 g\/h\u003c\/b\u003e, \u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"85\"\u003e22 g\/h\u003c\/b\u003e, and \u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"94\"\u003e35 g\/h\u003c\/b\u003e to cover any pool volume.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eZodiac TRi 10 Reference:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"26\"\u003eR0758400\u003c\/b\u003e (Production: \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"48\"\u003e10 g\/h\u003c\/b\u003e).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eZodiac TRi 18 Reference:\u003c\/b\u003e \u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"26\"\u003eR0758500\u003c\/b\u003e (Production: \u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"48\"\u003e18 g\/h\u003c\/b\u003e).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eZodiac TRi 22 Reference:\u003c\/b\u003e \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"26\"\u003eR0758600\u003c\/b\u003e (Production: \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"48\"\u003e22 g\/h\u003c\/b\u003e).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eZodiac TRi 35 Reference:\u003c\/b\u003e \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"26\"\u003eR0758700\u003c\/b\u003e (Production: \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"48\"\u003e35 g\/h\u003c\/b\u003e).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,4,0\"\u003e\u003cb data-path-to-node=\"12,4,0\" data-index-in-node=\"0\"\u003eEquipment Compatibility:\u003c\/b\u003e Zodiac \u003cb data-path-to-node=\"12,4,0\" data-index-in-node=\"34\"\u003eTRi\u003c\/b\u003e, \u003cb data-path-to-node=\"12,4,0\" data-index-in-node=\"39\"\u003eTRi Expert\u003c\/b\u003e, \u003cb data-path-to-node=\"12,4,0\" data-index-in-node=\"51\"\u003eeXO iQ\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,5,0\"\u003e\u003cb data-path-to-node=\"12,5,0\" data-index-in-node=\"0\"\u003eElectrode Material:\u003c\/b\u003e Titanium with noble metal coating.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,6,0\"\u003e\u003cb data-path-to-node=\"12,6,0\" data-index-in-node=\"0\"\u003eCleaning System:\u003c\/b\u003e Polarity reversal.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eCompatibility and Installation Protocols\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"14\"\u003eThe \u003cb data-path-to-node=\"14\" data-index-in-node=\"3\"\u003eZodiac TRi Cell Electrode\u003c\/b\u003e is compatible with the \u003cb data-path-to-node=\"14\" data-index-in-node=\"65\"\u003eTRi\u003c\/b\u003e and \u003cb data-path-to-node=\"14\" data-index-in-node=\"71\"\u003eeXO\u003c\/b\u003e platforms. To ensure system efficiency, the cell must be installed in a section with constant water flow and downstream of the filtration and heating systems.\u003c\/p\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not use on equipment from other manufacturers. The use of non-original spare parts alters the electrical resistance of the circuit, which voids the official warranty and reduces the service life of the chlorinator's electronic components.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"17,0,0\"\u003e\u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"0\"\u003eHow can I know which exact Zodiac TRi cell reference I need?\u003c\/b\u003e You must verify the name of your equipment (TRi 10, 18, 22, or 35) on the power supply. Each model requires its specific reference (\u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"208\"\u003eR0758400\u003c\/b\u003e to \u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"219\"\u003eR0758700\u003c\/b\u003e) for the electronics to correctly manage the electrolysis power.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"17,1,0\"\u003e\u003cb data-path-to-node=\"17,1,0\" data-index-in-node=\"0\"\u003eIs it normal for my equipment to indicate \"Low Salt\" if the salt level is correct?\u003c\/b\u003e Yes, this is the primary indicator that the \u003cb data-path-to-node=\"17,1,0\" data-index-in-node=\"125\"\u003eZodiac TRi Cell Electrode\u003c\/b\u003e has exhausted its noble metal coating. As it loses conductivity, the electronics interpret it as a lack of salt, signaling that the cell needs to be replaced.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"17,2,0\"\u003e\u003cb data-path-to-node=\"17,2,0\" data-index-in-node=\"0\"\u003eCan I install a 35 g\/h cell on a TRi 22 unit?\u003c\/b\u003e No. The power supply is calibrated for a specific current intensity. Installing a higher-capacity cell can cause communication errors or damage to the chlorinator's electronic board.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eQ-Tech Engineering Support\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"19\"\u003eAt Q-tech.es we offer specialized technical assistance for the optimization of Zodiac water treatment systems. If you have questions about compatibility or require technical support for the installation of your \u003cb data-path-to-node=\"19\" data-index-in-node=\"212\"\u003eZodiac TRi Cell Electrode\u003c\/b\u003e, contact our field engineers.\u003c\/p\u003e","brand":"Zodiac","offers":[{"title":"eXO iQ 10 g\/h","offer_id":42546081071330,"sku":"ZO-R0758400","price":488.0,"currency_code":"EUR","in_stock":true},{"title":"eXO iQ 18 g\/h","offer_id":42546081104098,"sku":"ZO-R0758500","price":584.0,"currency_code":"EUR","in_stock":true},{"title":"eXO iQ 22 g\/h","offer_id":42546081136866,"sku":"ZO-R0758600","price":775.0,"currency_code":"EUR","in_stock":true},{"title":"eXO iQ 35 g\/h","offer_id":42546081169634,"sku":"ZO-R0758700","price":1031.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/zodiac-electrodo-celula-zodiac-tri-electrodo-celula-zodiac-tri-10-g-h-52965461557592.jpg?v=1702915496"},{"product_id":"celula-recambio-original-sugar-valley-hidrolife-klx-salt-swim","title":"Sugar Valley Hydrolife Cell - KLX - AR FLO ADVANCED - Salt\u0026Swim 2.0","description":"\u003cdiv style=\"text-align: center;\"\u003e\n\n\u003cmeta charset=\"utf-8\"\u003e\n\n\u003ch3 style=\"text-align: left;\" data-path-to-node=\"6\"\u003eSugar Valley Cell: High-Fidelity Analytical Engineering\u003c\/h3\u003e\n\n\u003cp style=\"text-align: left;\" data-path-to-node=\"7\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"7\"\u003eSugar Valley Replacement Cell\u003c\/b\u003e is the original electrolysis component designed for the precise generation of active chlorine. This noble metal-coated titanium electrode ensures stable and efficient disinfection in high-performance water control systems. The cost of inaction when using low-quality compatible cells includes erratic readings, increased electrical consumption, and premature failure of the chlorinator's power board. The \u003cb data-index-in-node=\"480\" data-path-to-node=\"7\"\u003eSugar Valley Cell\u003c\/b\u003e resolves these operational risks through stable signal transfer and a linear response to disinfection demand.\u003c\/p\u003e\n\n\u003ch3 style=\"text-align: left;\" data-path-to-node=\"8\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8\"\u003eElectrochemical Performance and Operational Stability\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp style=\"text-align: left;\" data-path-to-node=\"9\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"9\"\u003eSugar Valley Replacement Cell\u003c\/b\u003e stands out for its plate architecture, which is optimized for demanding water treatment environments. Its original manufacturing ensures a long service life and minimal production drift, optimizing the technical maintenance of the installation.\u003c\/p\u003e\n\n\u003cul style=\"text-align: left;\" data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eHigh-Purity Titanium Plates:\u003c\/b\u003e The electrodes utilize a special coating that maximizes service life and improves hydrolysis efficiency.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eMulti-Platform Compatibility:\u003c\/b\u003e Manufacturer-validated design to function with total precision in Hidrolife, Bionet, Neosal, KLX, AR Flo, and Salt \u0026amp; Swim 2.0 equipment.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eLow-Maintenance Architecture:\u003c\/b\u003e The plates are designed to facilitate self-cleaning cycles via polarity reversal, minimizing the accumulation of calcareous deposits.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eOptimized Energy Efficiency:\u003c\/b\u003e The original design minimizes the electrical resistance of the assembly, reducing operating temperature and protecting the equipment's electronics.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: left;\" data-path-to-node=\"11\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11\"\u003eMechanical Robustness and Industrial Safety Standards\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp style=\"text-align: left;\" data-path-to-node=\"12\"\u003eThe manufacturing of the \u003cb data-index-in-node=\"21\" data-path-to-node=\"12\"\u003eSugar Valley Replacement Cell\u003c\/b\u003e follows industrial protocols for electrochemical instrumentation. Its design allows for rapid replacement within the container housing, ensuring operational continuity in residential and commercial installations.\u003c\/p\u003e\n\n\u003cul style=\"text-align: left;\" data-path-to-node=\"13\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,0,0\"\u003eHigh-Fidelity Connectivity:\u003c\/b\u003e Connection terminals are designed to prevent overheating and ensure uninterrupted power transmission.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,1,0\"\u003eSupport-Free Design:\u003c\/b\u003e Only the internal cell (electrode) is supplied, allowing the original container housing to be reused and reducing waste.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,2,0\"\u003eSugar Valley Factory Certification:\u003c\/b\u003e Each unit is verified to comply with the nominal chlorine production curve specified for each model.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,3,0\"\u003eSystem Sustainability:\u003c\/b\u003e By maintaining optimal conductivity, the cell contributes to the longevity of the hydraulic infrastructure and the biological safety of the water.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch4 style=\"text-align: left;\" data-path-to-node=\"14\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h4\u003e\n\n\u003cul style=\"text-align: left;\" data-path-to-node=\"15\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,0,0\"\u003eElectrode Material:\u003c\/b\u003e Titanium with noble metal coating.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,1,0\"\u003eEquipment Compatibility:\u003c\/b\u003e Hidrolife, Bionet, Neosal, KLX, AR Flo Advanced, Salt \u0026amp; Swim 2.0.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,2,0\"\u003eFunction:\u003c\/b\u003e Electrode replacement for salt chlorination and hydrolysis.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,3,0\"\u003ePlate Cleaning:\u003c\/b\u003e Compatible with automatic polarity reversal.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,4,0\"\u003eSupply Type:\u003c\/b\u003e Cell without support\/container housing.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,5,0\"\u003eNominal Service Life:\u003c\/b\u003e Variable according to model and salinity conditions.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: left;\" data-path-to-node=\"16\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16\"\u003eCompatibility and Application Limits\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp style=\"text-align: left;\" data-path-to-node=\"17\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"17\"\u003eSugar Valley Replacement Cell\u003c\/b\u003e is compatible exclusively with Sugar Valley control systems and their licensed brands manufactured under their technology. It must be installed correctly oriented within the original container housing to ensure cross-flow of water.\u003c\/p\u003e\n\n\u003cp style=\"text-align: left;\" data-path-to-node=\"17\"\u003e\u003cb data-index-in-node=\"284\" data-path-to-node=\"17\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not use in equipment not validated by the manufacturer. Do not clean the plates with metallic elements or high-concentration acids. Maintaining water balance (pH and alkalinity) is required to prevent accelerated wear of the titanium coating.\u003c\/p\u003e\n\n\u003ch3 style=\"text-align: left;\" data-path-to-node=\"18\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"18\"\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cul style=\"text-align: left;\" data-path-to-node=\"19\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"19,0,0\"\u003eCan I use this cell in a Salt \u0026amp; Swim 2.0 chlorinator if it is not originally from Sugar Valley?\u003c\/b\u003e The \u003cb data-index-in-node=\"102\" data-path-to-node=\"19,0,0\"\u003eSugar Valley Replacement Cell\u003c\/b\u003e is valid exclusively for the versions of the Salt \u0026amp; Swim 2.0 manufactured with Sugar Valley technology. Verify that your equipment uses compatible electronics before performing the technical replacement to ensure functionality.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"19,1,0\"\u003eWhy is the replacement sold without the transparent container housing?\u003c\/b\u003e The container housing is a passive element that does not suffer chemical wear. Supplying only the internal \u003cb data-index-in-node=\"165\" data-path-to-node=\"19,1,0\"\u003eSugar Valley Cell\u003c\/b\u003e allows for a reduction in maintenance costs for the client and minimizes environmental impact by leveraging the existing hydraulic infrastructure.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"19,2,0\"\u003eHow do I know when it is necessary to replace my chlorinator's electrode?\u003c\/b\u003e You should replace the cell if the equipment indicates \"Low Salt\" despite having the correct levels, or if chlorine production is nil after manual cleaning. An exhausted cell exhibits visible wear on the dark coating of the titanium plates.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: left;\" data-path-to-node=\"20\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"20\"\u003eQ-Tech Engineering Support\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp style=\"text-align: left;\" data-path-to-node=\"21\"\u003eAt Q-tech.es, we provide specialized technical assistance for the configuration of Sugar Valley electrochemical instrumentation. If you require installation support or on-site technical assistance for your \u003cb data-index-in-node=\"211\" data-path-to-node=\"21\"\u003eSugar Valley Replacement Cell\u003c\/b\u003e, contact our field engineers.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv style=\"position: absolute; left: 24px; top: 169.062px;\" id=\"gtx-trans\"\u003e\n\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"Sugar Valley","offers":[{"title":"RC08 8g electrolysis cell","offer_id":19637549269080,"sku":"PS-13359\/SCP-HAY-450-1137","price":335.0,"currency_code":"EUR","in_stock":true},{"title":"RC16 electrolysis cell 16g","offer_id":19637577285720,"sku":"PS-11373\/SCP-HAY-450-1138","price":425.0,"currency_code":"EUR","in_stock":true},{"title":"RC22 electrolysis cell 22g","offer_id":19637577318488,"sku":"PS-11374\/SCP-HAY-450-1139","price":499.0,"currency_code":"EUR","in_stock":true},{"title":"RC33 33g electrolysis cell","offer_id":19637577351256,"sku":"PS-11375\/SCP-HAY-450-1140","price":604.0,"currency_code":"EUR","in_stock":true},{"title":"50g electrolysis cell (2016 or later)","offer_id":19637577416792,"sku":"PS-14488\/SCP-HAY-450-0086","price":1159.0,"currency_code":"EUR","in_stock":true},{"title":"85g electrolysis cell","offer_id":19637577449560,"sku":"PS-11602","price":2225.0,"currency_code":"EUR","in_stock":true},{"title":"125g electrolysis cell","offer_id":19637577482328,"sku":"PS-11603","price":2925.0,"currency_code":"EUR","in_stock":true},{"title":"175g electrolysis cell","offer_id":19637577515096,"sku":"PS-11604","price":4650.0,"currency_code":"EUR","in_stock":true},{"title":"Electrolysis cell 250g","offer_id":19637577547864,"sku":"PS-11605","price":6225.0,"currency_code":"EUR","in_stock":true},{"title":"350g electrolysis cell (2 cells)","offer_id":19637577580632,"sku":"PS-11606","price":9150.0,"currency_code":"EUR","in_stock":true},{"title":"Electrolysis cell 500g (2 cells)","offer_id":19637577613400,"sku":"PS-11607","price":12485.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/sugar-valley-celula-electrodo-para-hidrolife-y-bionet-de-sugar-valley-celula-electrolisis-8gr-52965540397400.jpg?v=1702916048"},{"product_id":"electrodo-original-astral-sel-9-placas-astralpool","title":"Astral Sel 9-plate electrode AstralPool","description":"\u003ch3 data-path-to-node=\"6\"\u003eAstral Sel 9-Plate: High-Durability Electrolysis Engineering\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"7\"\u003eAstral Sel 9-plate electrode\u003c\/b\u003e is the original disinfection component for AstralPool salt chlorination systems. This device uses titanium plates coated with noble metals to transform sodium chloride into a high-purity active disinfectant. The cost of inaction when using compatible electrodes results in poor disinfection and a risk of short circuits in the control equipment. The \u003cb data-index-in-node=\"426\" data-path-to-node=\"7\"\u003eAstral Sel Cell\u003c\/b\u003e ensures stable chlorine production, protecting the health of users and the technical integrity of the installation.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eDisinfection Efficiency via Reinforced Titanium Plates\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-index-in-node=\"10\" data-path-to-node=\"9\"\u003eAstral Sel 9-plate\u003c\/b\u003e cell is designed to maximize electrical contact surface within the water flow. This engineering configuration allows for efficient hydrolysis even under conditions of high chemical demand.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eLong-Lasting Coating:\u003c\/b\u003e The plates feature a special treatment that extends effective operating hours in aggressive saline environments.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eHomogeneous Production:\u003c\/b\u003e The 9-plate design ensures a constant release of free chlorine, avoiding oxidation spikes that damage the pool liner.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eOperational Sustainability:\u003c\/b\u003e Optimizes the salt chlorinator's electrical consumption by requiring less intensity to generate the necessary oxidation potential.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003ePrecision Installation:\u003c\/b\u003e The connection terminal is designed for a perfect fit, preventing terminal overheating caused by loose contacts.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eMechanical Robustness and Safety Standards\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003eThe construction of the \u003cb data-index-in-node=\"20\" data-path-to-node=\"12\"\u003eAstral Sel Electrode\u003c\/b\u003e follows AstralPool's industrial quality standards. Its architecture facilitates rapid replacement in the technical room, reducing downtime in residential and commercial facilities.\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,0,0\"\u003eChemically Resistant Body:\u003c\/b\u003e The support materials are prepared to withstand the injection of pH correctors and high temperatures in the return flow.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,1,0\"\u003eProtected Terminals:\u003c\/b\u003e Electrical connection points feature protection to prevent corrosion from ambient humidity inside the cell.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,2,0\"\u003ePolarity Reversal Architecture:\u003c\/b\u003e Designed specifically to work with the self-cleaning cycles of Astral Sel equipment, minimizing scale buildup.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,3,0\"\u003eFactory Certification:\u003c\/b\u003e Each electrode undergoes conductivity tests to ensure it meets the specified grams of production per hour.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cmeta charset=\"utf-8\"\u003e\n\n\u003cp\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eAvailable in 4 models:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"padding-left: 30px;\"\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eFor Sel Astral 40: 28419 (former ref. 4408060124)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eFor Astral Sel 60 \/ Sel Pure 60: 54054 (former ref. 4408060125)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eFor Astral Sel 100 \/ Sel Pure 100: 54055 (former ref. 4408060126)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eFor Astral Sel 160 \/ Sel Pure 160: 54056 (former ref. 4408060127)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"14\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,0,0\"\u003eNumber of Plates:\u003c\/b\u003e 9 titanium plates.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,1,0\"\u003eBrand:\u003c\/b\u003e AstralPool (Original).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,2,0\"\u003eCompatibility:\u003c\/b\u003e Fluidra \u003cstrong\u003eAstral Sel and Sel Pure\u003c\/strong\u003e systems.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,3,0\"\u003eCoating Material:\u003c\/b\u003e Precious metal mix (Ruthenium\/Iridium).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,4,0\"\u003eCleaning Type:\u003c\/b\u003e Compatible with electronic polarity reversal.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,5,0\"\u003eEstimated Lifespan:\u003c\/b\u003e Between \u003cb data-index-in-node=\"26\" data-path-to-node=\"15,5,0\"\u003e3000\u003c\/b\u003e and \u003cb data-index-in-node=\"33\" data-path-to-node=\"15,5,0\"\u003e5000 hours\u003c\/b\u003e (depending on water hardness).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,6,0\"\u003eElectrical Connection:\u003c\/b\u003e Threaded or pressure terminals (depending on manufacturing version).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eCompatibility and Application Limits\u003c\/h3\u003e\n\u003cp data-path-to-node=\"17\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"17\"\u003eAstral Sel 9-plate electrode\u003c\/b\u003e is exclusively compatible with salt chlorinators in the Astral Sel and Sel Pure range that use this plate configuration. It must be installed after the filter and before any heating system.\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cb data-index-in-node=\"230\" data-path-to-node=\"17\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not submerge in high-concentration acidic solutions (greater than 10%) for prolonged periods, as this degrades the plate coating. Do not operate with salinity below \u003cb data-index-in-node=\"441\" data-path-to-node=\"17\"\u003e3000 ppm\u003c\/b\u003e to avoid premature titanium wear.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"18\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"19,0,0\"\u003eWhy choose the original AstralPool electrode instead of a compatible one?\u003c\/b\u003e The original \u003cb data-index-in-node=\"80\" data-path-to-node=\"19,0,0\"\u003eAstral Sel Electrode\u003c\/b\u003e ensures that the chlorinator correctly detects water conductivity. Compatible models often trigger \"low salt\" errors and have up to 50% shorter lifespans due to their low precious metal content.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"19,1,0\"\u003eWhen should I replace my Astral Sel 9-plate cell?\u003c\/b\u003e You should perform the replacement when you observe that chlorine production is null despite having the correct salt levels (approx. \u003cb data-index-in-node=\"185\" data-path-to-node=\"19,1,0\"\u003e4000 ppm\u003c\/b\u003e). If the plates are white or worn out after cleaning, their chemical reaction capacity has been exhausted.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"19,2,0\"\u003eHow can I extend the life of this replacement part?\u003c\/b\u003e Keep the water pH between \u003cb data-index-in-node=\"76\" data-path-to-node=\"19,2,0\"\u003e7.2\u003c\/b\u003e and \u003cb data-index-in-node=\"82\" data-path-to-node=\"19,2,0\"\u003e7.4\u003c\/b\u003e. Uncontrolled pH forces the cell to work more hours than necessary, accelerating the wear of the \u003cb data-index-in-node=\"236\" data-path-to-node=\"19,2,0\"\u003eAstral Sel\u003c\/b\u003e titanium plate coating.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"20\"\u003eQ-Tech Engineering Support\u003c\/h3\u003e\n\u003cp data-path-to-node=\"21\"\u003eAt Q-tech.es, we offer personalized technical assistance for professional installers and private customers. If you need to validate the compatibility of the \u003cb data-index-in-node=\"146\" data-path-to-node=\"21\"\u003eAstral Sel Electrode\u003c\/b\u003e with your equipment or require support during startup, contact our field engineers.\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"AstralPool","offers":[{"title":"For Astral Sel 40 - 9 plates","offer_id":33040204562570,"sku":"AS-28419","price":833.0,"currency_code":"EUR","in_stock":true},{"title":"For Astral Sel 60 - 9 plates","offer_id":33040103145610,"sku":"AS-54054","price":1057.0,"currency_code":"EUR","in_stock":true},{"title":"For Astral Sel 100 - 9 plates","offer_id":33040103211146,"sku":"AS-54055","price":1150.0,"currency_code":"EUR","in_stock":true},{"title":"For Astral Sel 160 - 9 plates","offer_id":33040103243914,"sku":"AS-54056","price":1300.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/astralpool-electrodo-astral-sel-9-placas-astralpool-para-astral-sel-40-9-placas-52965582963032.jpg?v=1702916339"},{"product_id":"celula-recambio-zodiac-ei-ei2-gensalt-original","title":"Zodiac Ei, Ei2, and GenSalt Cell","description":"\u003cp data-path-to-node=\"6\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"6\"\u003eZodiac Ei and Ei2 chlorinator cell electrode\u003c\/b\u003e is the critical power component for disinfectant generation via salt electrolysis. This original spare part ensures operational continuity and electrochemical efficiency in Zodiac water treatment systems.\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe cost of inaction when operating with a depleted cell includes the proliferation of pathogens due to low chlorine production, overheating of the power supply, and inefficient electrical consumption. The \u003cb data-index-in-node=\"212\" data-path-to-node=\"7\"\u003eoriginal Zodiac cell\u003c\/b\u003e resolves these risks through high-purity titanium electrodes with a long-lasting catalytic coating.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8\"\u003eElectrodynamic Performance and Intelligent Self-Cleaning\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"9\"\u003eZodiac Ei and Ei2 chlorinator cell electrode\u003c\/b\u003e stands out for its ability to operate under variable hydraulic conditions without loss of efficiency. Its design allows for the immediate recovery of the chlorinator's nominal performance, ensuring water biosecurity.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eSimplified Technical Replacement:\u003c\/b\u003e The connection system is designed for direct replacement by the operator, minimizing technical downtime.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003ePolarity Reversal Technology:\u003c\/b\u003e The electrodes are self-cleaning, which prevents the accumulation of calcareous deposits and extends the service life of the spare part.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eIndustrial-Grade Materials:\u003c\/b\u003e Manufactured entirely from titanium alloy with a noble metal coating for maximum conductivity.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eProduction Optimization:\u003c\/b\u003e Available in \u003cb data-index-in-node=\"61\" data-path-to-node=\"10,3,0\"\u003e10 g\/h\u003c\/b\u003e, \u003cb data-index-in-node=\"69\" data-path-to-node=\"10,3,0\"\u003e18 g\/h\u003c\/b\u003e, \u003cb data-index-in-node=\"77\" data-path-to-node=\"10,3,0\"\u003e20 g\/h\u003c\/b\u003e, and \u003cb data-index-in-node=\"86\" data-path-to-node=\"10,3,0\"\u003e25 g\/h\u003c\/b\u003e configurations to adapt to different pool volumes.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003eEquipment Compatibility:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli data-path-to-node=\"12,0,0\"\u003eZodiac \u003cb data-index-in-node=\"34\" data-path-to-node=\"12,0,0\"\u003eEi W383520;\u003c\/b\u003e \u003c\/li\u003e\n\n\u003cli data-path-to-node=\"12,0,0\"\u003e\n\n\u003cb data-index-in-node=\"38\" data-path-to-node=\"12,0,0\"\u003eEi2 Expert WW000063;\u003c\/b\u003e \u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eEi2 WW000066\u003c\/strong\u003e;\u003c\/li\u003e\n\n\u003cli data-path-to-node=\"12,0,0\"\u003e\n\n\u003cb data-index-in-node=\"50\" data-path-to-node=\"12,0,0\"\u003eGenSalt OE iQ 77383 - 77386;\u003c\/b\u003e \u003c\/li\u003e\n\n\u003cli data-path-to-node=\"12,0,0\"\u003e\u003cb data-index-in-node=\"62\" data-path-to-node=\"12,0,0\"\u003eGenSalt OT WW000161 - WW000325;\u003c\/b\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cb data-index-in-node=\"62\" data-path-to-node=\"12,0,0\"\u003eGenSalt OE WW000096\u003c\/b\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cb data-index-in-node=\"62\" data-path-to-node=\"12,0,0\"\u003eEi2 iQ 77377 - 77380\u003c\/b\u003e\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,1,0\"\u003eElectrode Material:\u003c\/b\u003e \u003cb data-index-in-node=\"36\" data-path-to-node=\"12,1,0\"\u003eTitanium\u003c\/b\u003e alloy with catalytic coating.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,2,0\"\u003eCleaning System:\u003c\/b\u003e Automatic via \u003cb data-index-in-node=\"36\" data-path-to-node=\"12,2,0\"\u003epolarity reversal\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,3,0\"\u003eAvailable Models:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,3,1,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,3,1,0,0\"\u003e10 g\/h:\u003c\/b\u003e Reference \u003cb data-index-in-node=\"19\" data-path-to-node=\"12,3,1,0,0\"\u003eR0758800\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,3,1,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,3,1,1,0\"\u003e18 g\/h:\u003c\/b\u003e Reference \u003cb data-index-in-node=\"19\" data-path-to-node=\"12,3,1,1,0\"\u003eR0758900\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,3,1,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,3,1,2,0\"\u003e20 g\/h:\u003c\/b\u003e Reference \u003cb data-index-in-node=\"19\" data-path-to-node=\"12,3,1,2,0\"\u003eR0673700\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,3,1,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,3,1,3,0\"\u003e25 g\/h:\u003c\/b\u003e Reference \u003cb data-index-in-node=\"19\" data-path-to-node=\"12,3,1,3,0\"\u003eR0759000\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13\"\u003eCompatibility and Installation Protocols\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"14\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"14\"\u003eZodiac Ei and Ei2 chlorinator cell electrode\u003c\/b\u003e is compatible with \u003cb data-index-in-node=\"110\" data-path-to-node=\"14\"\u003eEi\u003c\/b\u003e and \u003cb data-index-in-node=\"115\" data-path-to-node=\"14\"\u003eGenSalt\u003c\/b\u003e salt electrolysis platforms. To ensure warranty validity and system efficiency, the cell must be installed in a section of piping with constant flow and downstream of the filtration system.\u003c\/p\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not use with equipment from manufacturers other than Zodiac. The use of non-original cells invalidates the chlorinator's electrical safety certification and may cause irreparable damage to the power board due to impedance mismatch.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16\"\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"17,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"17,0,0\"\u003eHow do I identify which Zodiac cell model I need for my equipment?\u003c\/b\u003e Check the technical label on your power supply or on the old cell. The production capacities (\u003cb data-index-in-node=\"184\" data-path-to-node=\"17,0,0\"\u003e10 g\/h\u003c\/b\u003e, \u003cb data-index-in-node=\"192\" data-path-to-node=\"17,0,0\"\u003e18 g\/h\u003c\/b\u003e, \u003cb data-index-in-node=\"200\" data-path-to-node=\"17,0,0\"\u003e20 g\/h\u003c\/b\u003e, or \u003cb data-index-in-node=\"209\" data-path-to-node=\"17,0,0\"\u003e25 g\/h\u003c\/b\u003e) are specific to each chlorinator model and must be respected to avoid system errors.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"17,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"17,1,0\"\u003eIs it necessary to hire a professional to change the Ei2 Expert cell?\u003c\/b\u003e The \u003cb data-index-in-node=\"79\" data-path-to-node=\"17,1,0\"\u003eoriginal Zodiac cell\u003c\/b\u003e is designed for a simple and quick replacement that can be performed by the owner. It only requires disconnecting the power, removing the depleted cell, and inserting the new spare part by following the integrated alignment guides.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"18\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"18\"\u003eQ-Tech Engineering Support\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"19\"\u003eAt Q-tech.es, we provide specialized technical assistance for the optimization of Zodiac electrolysis systems. If you require support for identifying your model or technical assistance for commissioning, please contact our field engineers by phone or in person.\u003c\/p\u003e","brand":"Zodiac","offers":[{"title":"Zodiac electrolysis cell 10 g\/h R0758800","offer_id":39909210587289,"sku":"ZO-R0758800","price":349.0,"currency_code":"EUR","in_stock":true},{"title":"Zodiac 18 g\/h electrolysis cell R0758900","offer_id":39909210620057,"sku":"ZO-R0758900","price":525.0,"currency_code":"EUR","in_stock":true},{"title":"Zodiac electrolysis cell 20 g\/h R0673700","offer_id":49759880446296,"sku":"ZO-R0673700","price":463.0,"currency_code":"EUR","in_stock":true},{"title":"Zodiac electrolysis cell 25 g\/h R0759000","offer_id":39909210652825,"sku":"ZO-R0759000","price":652.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/zodiac-electrodo-celula-para-clorador-ei-de-zodiac-celula-electrolisis-zodiac-10-g-h-r0758800-52965615993176.jpg?v=1702916600"},{"product_id":"electrodo-original-astralpool-basic-sel-clear-7-placas","title":"AstralPool Sel Clear 7-plate Basic Electrode","description":"\u003ch3 data-path-to-node=\"6\"\u003eAstralPool Basic Sel Clear 7-Plate: Original Salt Electrolysis Engineering\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"7\"\u003eAstralPool Basic Sel Clear 7-Plate Electrode\u003c\/b\u003e is the original disinfection component designed for Basic Sel and Sel Clear salt chlorination systems. This electrode uses high-purity titanium plates to convert sodium chloride into active chlorine consistently and efficiently. The cost of inaction when using compatible electrodes is poor disinfection and possible failure of the equipment's power board. The \u003cb data-index-in-node=\"444\" data-path-to-node=\"7\"\u003eAstralPool Basic Sel Clear\u003c\/b\u003e guarantees stable chlorine production, protecting user health and the lifespan of the electronic controller.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eOperational Efficiency and Self-Cleaning via Polarity Reversal\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"9\"\u003eAstralPool Basic Sel Clear\u003c\/b\u003e with 7 plates optimizes the electrolysis process with a contact surface calculated for systems of up to \u003cb data-index-in-node=\"147\" data-path-to-node=\"9\"\u003e55 m³\u003c\/b\u003e. The original design ensures that the electrical resistance remains within the manufacturer's nominal parameters.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eReinforced Titanium Plates:\u003c\/b\u003e The precious metal coating maximizes electron transfer and reduces premature electrode wear.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eSelf-Cleaning Technology:\u003c\/b\u003e The plate architecture is compatible with polarity reversal cycles, automatically removing limescale deposits.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eConstant Chlorine Production:\u003c\/b\u003e It generates up to \u003cb data-index-in-node=\"44\" data-path-to-node=\"10,2,0\"\u003e13 g\/h\u003c\/b\u003e of free chlorine, ensuring crystal-clear water even under high organic load conditions.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003ePrecision Installation:\u003c\/b\u003e The body design and connection terminals ensure a watertight fit that prevents hydraulic leaks and electrical corrosion.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cmeta charset=\"utf-8\"\u003e\n\n\u003cp\u003e\n\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\n\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eOriginal AstralPool electrode replacement for salt chlorinators from the \u003c\/span\u003e\n\u003c\/span\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\n\u003cstrong\u003e\n\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\n\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eAstral Sel Basic, Sel Clear, and Energy Sel series\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/strong\u003e\n\u003c\/span\u003e\n\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\n\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e .\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\n\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\n\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\n\u003cstrong\u003eAvailable in 3 models\u003c\/strong\u003e:\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\u003cdiv style=\"padding-left: 30px;\"\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\n\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eFor Astral Sel Basic \/ Sel Clear \/ Energy Sel 30: 54051 (old ref. 4408060203)\u003c\/span\u003e\n\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\n\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eFor Astral Sel Basic \/ Sel Clear \/ Energy Sel 55: 54052 (old ref. 4408060204)\u003c\/span\u003e\n\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\n\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eFor Astral Sel Basic \/ Sel Clear \/ Energy Sel 95: 54053 (old ref. 4408060205)\u003c\/span\u003e\n\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eMechanical Robustness and Industrial Safety Standards\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003eThe manufacturing of the \u003cb data-index-in-node=\"19\" data-path-to-node=\"12\"\u003eBasic Sel Clear Electrode\u003c\/b\u003e follows Fluidra's quality protocols. Its structure facilitates quick replacement in the technical room, reducing downtime in residential and commercial installations.\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,0,0\"\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,0,0\"\u003eChemically Resistant Body:\u003c\/b\u003e The support materials withstand direct injection of pH correctors and high water flow temperatures.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,1,0\"\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,1,0\"\u003eProtected Connection Terminals:\u003c\/b\u003e The design prevents overheating at contact points, protecting the control unit's wiring.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,2,0\"\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,2,0\"\u003eFactory Certification:\u003c\/b\u003e Each unit is verified to meet the chlorine production curve specified for Basic range models.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,3,0\"\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,3,0\"\u003eSystem Sustainability:\u003c\/b\u003e By maintaining optimal conductivity, the system consumes less energy to generate the required oxidation potential.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eCompatibility and Application Limits\u003c\/h3\u003e\n\u003cp data-path-to-node=\"17\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"17\"\u003eBasic Sel Clear 7-Plate Electrode\u003c\/b\u003e is exclusively compatible with AstralPool Basic series salt chlorinators designed for 7 plates. It must be installed after the filter and before any additional heating or chemical dosing system.\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\"\u003e\n\u003cb data-index-in-node=\"257\" data-path-to-node=\"17\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not clean the plates with metal objects or concentrated acidic solutions (maximum 10%). Do not operate with salinity lower than \u003cb data-index-in-node=\"409\" data-path-to-node=\"17\"\u003e3 g\/L\u003c\/b\u003e, as this causes accelerated wear of the titanium coating and loss of warranty.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"18\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,0,0\"\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"19,0,0\"\u003eWhy should I choose the original AstralPool electrode?\u003c\/b\u003e The original \u003cb data-index-in-node=\"80\" data-path-to-node=\"19,0,0\"\u003eAstralPool Basic Sel Clear\u003c\/b\u003e electrode ensures proper communication with the electronic board. Compatible models usually cause incorrect salt readings and have a lifespan up to 50% shorter due to the low quality of the titanium.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,1,0\"\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"19,1,0\"\u003eWhen is it necessary to replace my chlorinator's electrode?\u003c\/b\u003e You should replace it when chlorine production is insufficient despite having the correct salt levels (approx. \u003cb data-index-in-node=\"176\" data-path-to-node=\"19,1,0\"\u003e4 g\/L\u003c\/b\u003e). If the plates show visible wear or the equipment indicates a lack of production after cleaning, the electrode has exhausted its chemical capacity.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,2,0\"\u003e\n\u003cb data-index-in-node=\"0\" data-path-to-node=\"19,2,0\"\u003eHow can I extend the life of my 7-plate cell?\u003c\/b\u003e Keep the water pH between \u003cb data-index-in-node=\"84\" data-path-to-node=\"19,2,0\"\u003e7.2\u003c\/b\u003e and \u003cb data-index-in-node=\"90\" data-path-to-node=\"19,2,0\"\u003e7.4\u003c\/b\u003e. An uncontrolled pH forces the cell to work more hours to keep the water disinfected, which accelerates the wear of the noble metal coating of the \u003cb data-index-in-node=\"272\" data-path-to-node=\"19,2,0\"\u003eBasic Sel Clear\u003c\/b\u003e plates.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"20\"\u003eQ-Tech Engineering Support\u003c\/h3\u003e\n\u003cp data-path-to-node=\"21\"\u003eAt Q-tech.es we provide specialized technical assistance for the optimization of water treatment systems. If you need to validate the compatibility of the \u003cb data-index-in-node=\"160\" data-path-to-node=\"21\"\u003eAstralPool Basic Sel Clear\u003c\/b\u003e or on-site support for commissioning, contact our field engineers.\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\n\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\n\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003cp class=\"qt-nota-stock\"\u003e\u003cstrong\u003eAvailability and delivery times:\u003c\/strong\u003e we have this item in stock in our warehouse. Occasionally, depending on the time of year, an error in the stock update may occur. If there are no units available at the time of your order, we will order it urgently and inform you immediately of the updated delivery time.\u003c\/p\u003e\n","brand":"AstralPool","offers":[{"title":"For Astral Sel Clear 30","offer_id":42546364874978,"sku":"AS-54051","price":618.0,"currency_code":"EUR","in_stock":true},{"title":"For Astral Sel Clear 55","offer_id":42546364907746,"sku":"AS54052","price":897.0,"currency_code":"EUR","in_stock":true},{"title":"For Astral Sel Clear 95","offer_id":42546364940514,"sku":"AS-54053","price":1195.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/astralpool-electrodo-basic-sel-clear-7-placas-astralpool-para-astral-sel-clear-30-52965636505944.jpg?v=1702916722"},{"product_id":"vaso-celula-clorador-salino-sel-clear-basic-astralpool-4408060201","title":"Sel Clear\/Basic salt chlorinator cell vessel AstralPool 4408060201","description":"\u003cp\u003eOriginal replacement cell housing for AstralPool salt chlorinators, suitable for the following models:\u003c\/p\u003e\n\u003cp\u003e- Astral Sel Clear - 54041 - 54042 - 54043 - \u003ca href=\"https:\/\/spareparts.fluidra.com\/PDF\/931_4.PDF\" target=\"_blank\" title=\"AstralPool Sel Clear salt chlorinator cell housing 4408060201\" rel=\"noopener noreferrer\"\u003eDownload parts list\u003c\/a\u003e\n\u003c\/p\u003e\n\u003cp\u003e- Astral Sel Basic - 41654 - 41655 - 41656 - \u003ca href=\"https:\/\/spareparts.fluidra.com\/PDF\/631_3.PDF\" target=\"_blank\" title=\"AstralPool Sel Basic salt chlorinator cell housing 4408060201\" rel=\"noopener noreferrer\"\u003eDownload parts list\u003c\/a\u003e\n\u003c\/p\u003e\n\u003cp\u003e- Energy Sel - 71650 - 71651 - 71652 - \u003ca href=\"https:\/\/spareparts.fluidra.com\/PDF\/1362_2.PDF\" target=\"_blank\" title=\"AstralPool Energy Sel salt chlorinator cell housing 4408060201\" rel=\"noopener noreferrer\"\u003eDownload parts list\u003c\/a\u003e \u003c\/p\u003e\n\u003cp\u003e- Bering Sel - 64315 - \u003ca href=\"https:\/\/spareparts.fluidra.com\/PDF\/1386_1.PDF\" target=\"_blank\" title=\"AstralPool Bering Sel salt chlorinator cell housing 4408060201\" rel=\"noopener noreferrer\"\u003eDownload parts list\u003c\/a\u003e\n\u003c\/p\u003e\n\u003cp\u003e- Electrolisis Sel Basic - 27889 - 27890 - 27891 - \u003ca href=\"https:\/\/spareparts.fluidra.com\/PDF\/5038_4.PDF\" target=\"_blank\" title=\"AstralPool Electrolisis Sel Basic salt chlorinator cell housing 4408060201\" rel=\"noopener noreferrer\"\u003eDownload parts list \u003c\/a\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\u003cbr\u003eReference: 4408060201\u003c\/p\u003e\n\u003cp\u003eReplace the chlorinator cell housing with its original spare part to ensure complete transparency of the housing and monitor the condition of the cell at all times. \u003c\/p\u003e\n\u003cp class=\"qt-nota-stock\"\u003e\u003cstrong\u003eAvailability and delivery times:\u003c\/strong\u003e this item is in stock at our warehouse. Occasionally, depending on the time of year, an error may occur in the stock update. If no units are available at the time of your order, we will order them urgently and inform you immediately of the updated delivery time.\u003c\/p\u003e\n","brand":"AstralPool","offers":[{"title":"Default Title","offer_id":44689547985240,"sku":"AS-4408060201","price":193.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/astralpool-vaso-celula-clorador-salino-sel-clear-basic-astralpool-4408060201-default-title-52965651120472.jpg?v=1702916839"},{"product_id":"celula-recambio-rcb-baja-salinidad-hayward-oxilife-aquascenic","title":"RCB low salinity cell electrode Hayward AQR LS-Sugar Valley-UVScenic-Oxilife-Aquascenic","description":"\u003ch3 data-path-to-node=\"5\"\u003e\n\n\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eRCB Cell: Hydrolysis Engineering for Low Salinity\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe \u003cb data-path-to-node=\"6\" data-index-in-node=\"3\"\u003eLow Salinity RCB Replacement Cell\u003c\/b\u003e is the premium component designed for disinfection by hydrolysis in systems with minimal salt concentrations. This titanium electrode with an optimized coating ensures the generation of high-purity oxidizing agents in low-conductivity water. The cost of inaction when using standard cells in low-salinity equipment includes accelerated coating degradation, excessive power consumption, and control system failure. The \u003cb data-path-to-node=\"6\" data-index-in-node=\"531\"\u003eRCB Cell\u003c\/b\u003e addresses these operational risks with a plate surface calculated to operate with maximum efficiency in reduced salinity ranges.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003e\n\n\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eElectrochemical Performance and Stability in Low Conductivity\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"8\"\u003eThe \u003cb data-path-to-node=\"8\" data-index-in-node=\"3\"\u003eRCB Replacement Cell\u003c\/b\u003e stands out for its plate architecture designed for advanced hydrolysis and disinfection environments. Its manufacturing ensures a long service life and precise monitoring of the water condition, optimizing the technical maintenance of the installation.\u003c\/p\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"9,0,0\"\u003e\n\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eTitanium Plates with Premium Coating:\u003c\/b\u003e The electrodes use a specific noble metal alloy to work in low-conductivity conditions without compromising hydrolysis.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"9,1,0\"\u003e\n\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eAdvanced Multi-Brand Compatibility:\u003c\/b\u003e Validated design for \u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"67\"\u003eHayward AquaRite Low Salt\u003c\/b\u003e, \u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"94\"\u003eOxilife\u003c\/b\u003e, \u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"103\"\u003eAquascenic\u003c\/b\u003e, \u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"115\"\u003eUVScenic\u003c\/b\u003e and \u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"138\"\u003eSugar Valley\u003c\/b\u003e platforms.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"9,2,0\"\u003e\n\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eEfficient Water Management:\u003c\/b\u003e Allows the pool to remain disinfected with negligible salt levels, ideal for protecting sensitive linings and metal infrastructure components.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"9,3,0\"\u003e\n\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eStability in Reversal Cycles:\u003c\/b\u003e The plates withstand frequent self-cleaning cycles, maintaining operational efficiency and reducing the accumulation of calcium sediments.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"10\"\u003e\n\n\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eMechanical Robustness and Industrial Safety Standards\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"11\"\u003eThe manufacturing of the \u003cb data-path-to-node=\"11\" data-index-in-node=\"21\"\u003eRCB Replacement Cell\u003c\/b\u003e follows industrial protocols for advanced electrochemical instrumentation. Its design allows for quick and watertight replacement, ensuring operational continuity in high-level technical installations.\u003c\/p\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,0,0\"\u003e\n\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eHigh-Fidelity Connectivity:\u003c\/b\u003e Terminals designed to ensure stable power transmission, minimizing thermal resistance at contact points.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,1,0\"\u003e\n\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eLong-Lasting Architecture:\u003c\/b\u003e Reinforced construction to withstand the flow and pressure fluctuations common in high-capacity filtration systems.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,2,0\"\u003e\n\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eOPEX Optimization:\u003c\/b\u003e By operating efficiently at low salinity, the system reduces stress on the chlorinator power supply, extending the service life of the electronic equipment.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,3,0\"\u003e\n\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eProcess Sustainability:\u003c\/b\u003e Hydrolysis technology reduces dependence on traditional chemicals, naturally improving the biological safety of the water.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u0026lt;h4\u0026gt;Technical Specifications\u0026lt;\/h4\u0026gt;\u003c\/p\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"14,0,0\"\u003e\n\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eElectrode Material:\u003c\/b\u003e Titanium with precious metal coating for low salinity.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"14,1,0\"\u003e\n\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eTechnical Compatibility:\u003c\/b\u003e \u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"24\"\u003eHayward AQR LS\u003c\/b\u003e, \u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"40\"\u003eOxilife\u003c\/b\u003e, \u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"49\"\u003eAquascenic\u003c\/b\u003e, \u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"61\"\u003eUVScenic\u003c\/b\u003e, \u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"71\"\u003eSugar Valley\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"14,2,0\"\u003e\n\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eOperating Salinity Range:\u003c\/b\u003e Optimized for low conductivity (\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"66\"\u003e1.5 g\/L\u003c\/b\u003e to \u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"76\"\u003e2 g\/L\u003c\/b\u003e).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"14,3,0\"\u003e\n\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eApplied Technology:\u003c\/b\u003e Low-salinity hydrolysis and electrolysis.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"14,4,0\"\u003e\n\u003cb data-path-to-node=\"14,4,0\" data-index-in-node=\"0\"\u003eConnector Type:\u003c\/b\u003e High-resistance terminals for stable power transmission.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"14,5,0\"\u003e\n\u003cb data-path-to-node=\"14,5,0\" data-index-in-node=\"0\"\u003ePlate Cleaning:\u003c\/b\u003e Compatible with automatic polarity reversal systems.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003e\n\n\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003eCompatibility and Application Limits\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"16\"\u003eThe \u003cb data-path-to-node=\"16\" data-index-in-node=\"3\"\u003eLow Salinity RCB Replacement Cell\u003c\/b\u003e is exclusively compatible with low-conductivity systems manufactured by Sugar Valley or under Hayward license (LS Series). It must be installed following the indicated flow direction to avoid turbulence affecting the reading of the integrated flow probe.\u003c\/p\u003e\n\u003cp data-path-to-node=\"16\"\u003e\n\u003cb data-path-to-node=\"16\" data-index-in-node=\"324\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not use in standard salinity equipment (\u003cb data-path-to-node=\"16\" data-index-in-node=\"391\"\u003e4 g\/L\u003c\/b\u003e or higher, as the coating is specifically designed for low salt residue conditions. A strict water balance (pH between 7.2 and 7.4) is required to prevent premature plate wear.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"17\"\u003e\n\n\u003cb data-path-to-node=\"17\" data-index-in-node=\"0\"\u003eFrequently Asked Questions\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cul data-path-to-node=\"18\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"18,0,0\"\u003e\n\u003cb data-path-to-node=\"18,0,0\" data-index-in-node=\"0\"\u003eCan I use this cell in an Oxilife system of any power?\u003c\/b\u003e The \u003cb data-path-to-node=\"18,0,0\" data-index-in-node=\"72\"\u003eRCB Replacement Cell\u003c\/b\u003e must be selected according to the specific production of grams\/hour (\u003cb data-path-to-node=\"18,0,0\" data-index-in-node=\"150\"\u003eg\/h\u003c\/b\u003e) of your equipment. Check the nomenclature of your original model to ensure that the electrode's production capacity matches your controller's configuration.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"18,1,0\"\u003e\n\u003cb data-path-to-node=\"18,1,0\" data-index-in-node=\"0\"\u003eWhat are the benefits of low-salinity technology compared to normal chlorination?\u003c\/b\u003e The technology of the \u003cb data-path-to-node=\"18,1,0\" data-index-in-node=\"104\"\u003eRCB Cell\u003c\/b\u003e allows the water to be disinfected with a minimal amount of salt. This prevents the salty taste in the water, protects stainless steel components from corrosion, and is much gentler on users' skin and eyes.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"18,2,0\"\u003e\n\u003cb data-path-to-node=\"18,2,0\" data-index-in-node=\"0\"\u003eHow do I know if my low-salinity cell has reached the end of its service life?\u003c\/b\u003e The system usually indicates \"Salt Missing\" or \"Low Production\" persistently, even when the conductivity levels measured manually are correct. Physical wear or loss of the dark coating on the titanium plates is also observed.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"19\"\u003e\n\n\u003cb data-path-to-node=\"19\" data-index-in-node=\"0\"\u003eQ-Tech Engineering Support\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"20\"\u003eAt Q-tech.es we provide specialized technical assistance for the configuration of low-salinity electrochemical instrumentation. If you require support for the installation or in-person technical assistance for your \u003cb data-path-to-node=\"20\" data-index-in-node=\"21\"\u003eRCB Replacement Cell\u003c\/b\u003e, contact our field engineers by phone or in person.\u003c\/p\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: 24px; top: 169.062px;\"\u003e\n\n\u003cdiv class=\"gtx-trans-icon\"\u003e\n\n\u003cbr\u003e\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cp class=\"qt-nota-stock\"\u003e\u003cstrong\u003eAvailability and lead times:\u003c\/strong\u003e this item is in stock in our warehouse. Occasionally, depending on the time of year, an error in the stock update may occur. If no units are available at the time of your order, we will order it urgently and inform you immediately of the updated delivery time.\u003c\/p\u003e","brand":"Sugar Valley","offers":[{"title":"RCB5 - 8A - HD0 - OX0 hydrolysis cell","offer_id":46909599056216,"sku":"PS-12616","price":445.0,"currency_code":"EUR","in_stock":true},{"title":"RCB 16 hydrolysis cell - 15A - HD1 - OX1","offer_id":46909599088984,"sku":"PS-11382","price":489.0,"currency_code":"EUR","in_stock":true},{"title":"RCB 33 - 30A - HD2 - OX2 hydrolysis cell (2013 or earlier)","offer_id":46909599121752,"sku":"PS-11383","price":790.0,"currency_code":"EUR","in_stock":true},{"title":"RCB 33 - 30A - HD2 - OX2 hydrolysis cell (2014 or later)","offer_id":46909599154520,"sku":"PS-12510","price":745.0,"currency_code":"EUR","in_stock":true},{"title":"RCB 50 - 50A - HD3 - OX3 hydrolysis cell (2015 or earlier)","offer_id":46909599187288,"sku":"PS-11384","price":985.0,"currency_code":"EUR","in_stock":true},{"title":"RCB 50 - 50A - HD3 - OX3 hydrolysis cell (2016 or later)","offer_id":46909599220056,"sku":"PS-13742","price":1299.0,"currency_code":"EUR","in_stock":true},{"title":"RCB 85 - 80A - HD4 - OX4 hydrolysis cell","offer_id":46909599252824,"sku":"PS-11608","price":2599.0,"currency_code":"EUR","in_stock":true},{"title":"RCB 125 hydrolysis cell - 120A - HD5 - OX5","offer_id":46909599285592,"sku":"PS-11609","price":3350.0,"currency_code":"EUR","in_stock":true},{"title":"RCB 175 - 175A - HD6 - OX6 hydrolysis cell","offer_id":46909599318360,"sku":"PS-11610","price":4799.0,"currency_code":"EUR","in_stock":true},{"title":"RCB 250 Hydrolysis cell - 250A - HD7 - OX7","offer_id":46909599351128,"sku":"PS-11611","price":6880.0,"currency_code":"EUR","in_stock":true},{"title":"RCB 350 - 350A - HD8 - OX8 hydrolysis cell (includes 2 cells)","offer_id":46909599383896,"sku":"PS-11612","price":8875.0,"currency_code":"EUR","in_stock":true},{"title":"RCB 500 - 500A - HD9 - OX9 hydrolysis cell (includes 2 cells)","offer_id":46909599416664,"sku":"PS-11613","price":12999.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/sugar-valley-celula-electrodo-para-oxilife-uvscenic-aquascenic-y-da-gen-de-sugar-valley-celula-hidrolisis-8a-hd0-ox0-52965671403864.jpg?v=1702917005"},{"product_id":"celula-electrodo-para-cloradores-facileo-de-qp-pool-technologie","title":"Cell \/ electrode for Facileo salt chlorinators by QP Pool Technologie","description":"\u003ch3\u003eCell \/ electrode for Facileo chlorinators by QP Pool Technologie\u003c\/h3\u003e\n\u003ch4\u003eOpaque 4-plate monopolar cell QP Pool Technologie Facileo 517589:\u003c\/h4\u003e\n\u003cp\u003e- Monopolar cell\u003c\/p\u003e\n\u003cp\u003e- 4 plates\u003c\/p\u003e\n\u003cp\u003e- Manufacturer: Pool Technologie\u003c\/p\u003e\n\u003cp\u003e- Code: \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e517589\u003c\/span\u003e\n\u003c\/p\u003e\n\u003cp\u003e- Does not include links or gaskets\u003c\/p\u003e\n\u003ch4\u003eSuitable for the following chlorinators:\n\n\u003c\/h4\u003e\n\u003cp\u003e- Easy Salt\n\u003c\/p\u003e\n\u003cp\u003e- Facileo\n\u003c\/p\u003e\n\u003cp\u003e- QP Salt 50 (pre-2010)\n\u003c\/p\u003e\n\u003cp\u003e- QP Salt 50\n\u003c\/p\u003e\n\u003cp\u003e- QP Salt 70\n\u003c\/p\u003e\n\u003cp\u003e- QP Salt 80\n\u003c\/p\u003e\n\u003cp\u003e- QP Salt Duo 60 (2013)\n\u003c\/p\u003e\n\u003cp\u003e- QP Salt Top\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/p\u003e\n\u003cp class=\"qt-nota-stock\"\u003e\u003cstrong\u003eAvailability and lead times:\u003c\/strong\u003e this item is in stock at our warehouse. Occasionally, depending on the time of year, an error may occur in the stock update. If there are no units available at the time of your order, we would order it urgently and inform you immediately of the updated delivery time.\u003c\/p\u003e","brand":"QP","offers":[{"title":"Default Title","offer_id":46922752852312,"sku":"QP-517589","price":510.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/qp-celula-electrodo-para-cloradores-facileo-de-qp-pool-technologie-default-title-52965672223064.jpg?v=1702917009"},{"product_id":"recambio-electrodo-de-cobre-cu-ag-para-equipos-de-ionizacion-sugar-valley","title":"Copper Cu\/Ag electrode replacement for Sugar Valley ionization systems","description":"\u003ch3\u003eReplacement Cu\/Ag copper electrode for Sugar Valley ionization equipment.\u003c\/h3\u003e\n\u003cp\u003eThe copper ionization water purification system reduces the addition of chemicals in swimming pools, cooling towers, and boiler hot water (DHW) by between 40% and 90%.\u003c\/p\u003e\n\u003cp\u003ePack of 2 units.\u003c\/p\u003e\n\u003cp\u003eApprox. dimensions: 9 cm x 2 cm\u003c\/p\u003e\n\u003cp\u003e* Check the condition of the electrode nuts, as they may be affected by electrode wear.\u003c\/p\u003e\n\u003cp\u003e\n\u003cstrong\u003eRef. RDC01\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\n\u003cbr\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\n\u003cbr\u003e\n\n\u003c\/h3\u003e\n\u003cp class=\"qt-nota-stock\"\u003e\u003cstrong\u003eAvailability and lead times:\u003c\/strong\u003e this item is in stock at our warehouse. Occasionally, depending on the time of year, an error may occur in the stock update. If there are no units available at the time of your order, we will order them urgently and inform you immediately of the updated delivery time.\u003c\/p\u003e","brand":"Sugar Valley","offers":[{"title":"Default Title","offer_id":46978175304024,"sku":"HIDRO-RDC01","price":97.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/Electrodo-cu-ag-ionizacion-sugar-valley-01.webp?v=1743173158"},{"product_id":"junta-torica-para-celula-de-clorador-zodiac","title":"O-ring for Zodiac chlorinator cell","description":"\u003ch3\u003eO-ring for Zodiac chlorinator cell\u003c\/h3\u003e\n\u003cp\u003eManufacturer reference R0738500.\u003c\/p\u003e\n\u003ch3\u003eThis O-ring for Zodiac chlorinators is compatible with the following models:\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eZodiac Ei: W383510 - W383500 - W383520\u003c!----\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eZodiac Ei2: WW000064 - WW000065 - WW000066 - WW000244 - WW000245 - WW000246\u003c\/li\u003e\n\n\u003cli\u003eZodiac Ei2 Expert\u003c\/li\u003e\n\n\u003cli\u003eZodiac GenSalt OE: WW000094 - WW000096 - WW000247 - WW000249 - WW000248 - WW000095\u003c\/li\u003e\n\n\u003cli\u003eZodiac GenSalt OT: WW000160 - WW000159 - WW000161\u003c\/li\u003e\n\n\u003cli\u003eZodiac pH Link \/ Dual Link: WW000176 - W197525 - W197515 - WW000177\u003c\/li\u003e\n\n\u003cli\u003eZodiac TRi pH \/ TRi PRO\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp class=\"qt-nota-stock\"\u003e\u003cstrong\u003eAvailability and delivery times:\u003c\/strong\u003e this item is in stock at our warehouse. Occasionally, depending on the time of year, an error may occur in the stock update. If there are no units available at the time of your order, we would order it urgently and inform you immediately of the updated delivery time.\u003c\/p\u003e\n","brand":"Zodiac","offers":[{"title":"Default Title","offer_id":49759911280984,"sku":"AS-R0738500","price":11.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/JUNTA-TORICA-CELULA-ELECTRODO-ZODIAC-00.webp?v=1724242710"},{"product_id":"recambio-tuerca-para-electrodos-cu-ag-sugar-valley","title":"Replacement nut for Sugar Valley Cu\/Ag electrodes","description":"\u003ch3\u003eReplacement nut for Sugar Valley Cu\/Ag electrodes\u003c\/h3\u003e\n\u003cp\u003eNut for Cu\/Ag electrodes \u003cstrong\u003e(1 unit)\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003eIncludes top and bottom gaskets.\u003c\/p\u003e\n\u003cp\u003eManufacturer: Sugar Valley.\u003c\/p\u003e\n\u003cp\u003e\n\u003cstrong\u003eRef. RDD00\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\n\u003cbr\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\n\u003cbr\u003e\n\n\u003c\/h3\u003e\n\u003cp class=\"qt-nota-stock\"\u003e\u003cstrong\u003eAvailability and delivery times:\u003c\/strong\u003e this item is in stock at our warehouse. Occasionally, depending on the time of year, an error may occur in the stock update. If there are no units available at the time of your order, we would order it urgently and inform you immediately of the updated delivery time.\u003c\/p\u003e\n","brand":"Sugar Valley","offers":[{"title":"Default Title","offer_id":55204151329112,"sku":"PS-12845","price":24.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/tuerca-Electrodo-cu-ag-ionizacion-sugar-valley-RDD00-01.webp?v=1751354507"},{"product_id":"recambio-celula-hayward-turbocell-aquarite-original","title":"TurboCell cell for Aquarite","description":"\u003ch3 data-path-to-node=\"6\"\u003eHayward TurboCell: High-Performance Salt Electrolysis Engineering\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-path-to-node=\"7\" data-index-in-node=\"3\"\u003eHayward TurboCell\u003c\/b\u003e is the original replacement cell designed for AquaRite salt chlorination systems. This engineered component uses titanium plates coated with precious metals to transform salt into free chlorine efficiently and consistently. The cost of inaction when using low-quality compatible cells includes erratic disinfection and potential damage to the controller's electronic board. The \u003cb data-path-to-node=\"7\" data-index-in-node=\"433\"\u003eHayward TurboCell\u003c\/b\u003e resolves these operational risks by guaranteeing precise chlorine production and superior service life under intensive working conditions.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eTitanium Plate Technology and Disinfection Efficiency\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-path-to-node=\"9\" data-index-in-node=\"3\"\u003eHayward TurboCell\u003c\/b\u003e uses an oversized plate configuration that optimizes water hydrolysis. This technology allows for the maintenance of hospital-grade sanitation levels with a reduced salt concentration, protecting both user health and material integrity.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eNSF Certification:\u003c\/b\u003e The only original replacement that meets \u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"76\"\u003eNSF\u003c\/b\u003e performance and safety standards for commercial and residential pools.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eChemical Savings:\u003c\/b\u003e Reduces dependence on liquid or granular chlorine by generating pure disinfectant directly in the installation's return flow.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eSelf-Cleaning by Polarity Reversal:\u003c\/b\u003e The AquaRite system manages automatic cleaning cycles in the cell to eliminate lime scale without manual intervention.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eIntelligent Monitoring:\u003c\/b\u003e Integrates sensors that communicate critical data regarding water temperature and salinity levels to the central system in real time.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eChemical Robustness and Critical Installation Standards\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003eThe architecture of the \u003cb data-path-to-node=\"12\" data-index-in-node=\"22\"\u003eHayward TurboCell\u003c\/b\u003e is engineered for continuous operation in aggressive chemical environments. Its design facilitates rapid replacement in the technical room, minimizing downtime in critical installations such as hotels, sports clubs, or high-end residences.\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eHigh-Strength Transparent Housing:\u003c\/b\u003e Manufactured with technical polymers that allow for visual inspection of the plates without disassembling the equipment.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003ePlug and Play Connectivity:\u003c\/b\u003e Includes a reinforced \u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"70\"\u003e4.5-meter\u003c\/b\u003e connection cable with a watertight connector for interference-free data transmission.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eCorrosion Resistance:\u003c\/b\u003e The titanium plates are treated to withstand galvanic oxidation and wear from hydraulic friction.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eProduction Versatility:\u003c\/b\u003e Available in versions based on pool volume, ensuring proportional dosing tailored to actual demand.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"14\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eAvailable Models:\u003c\/b\u003e T-CELL-3 (up to 60 m3), T-CELL-9 (up to 95 m3), T-CELL-15 (up to 150 m3).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eElectrode Material:\u003c\/b\u003e Titanium with ruthenium and iridium coating.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eEstimated Service Life:\u003c\/b\u003e Up to \u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"26\"\u003e10,000 hours\u003c\/b\u003e of operation.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eCable Length:\u003c\/b\u003e \u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"20\"\u003e4.5 meters\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,4,0\"\u003e\u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure:\u003c\/b\u003e \u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"27\"\u003e2 bar\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,5,0\"\u003e\u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"0\"\u003eHydraulic Connections:\u003c\/b\u003e \u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"44\"\u003e2-inch\u003c\/b\u003e union fittings.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,6,0\"\u003e\u003cb data-path-to-node=\"15,6,0\" data-index-in-node=\"0\"\u003eCertifications:\u003c\/b\u003e \u003cb data-path-to-node=\"15,6,0\" data-index-in-node=\"17\"\u003eNSF 50\u003c\/b\u003e and CE marking.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,7,0\"\u003e\u003cb data-path-to-node=\"15,7,0\" data-index-in-node=\"0\"\u003eRecommended Salinity:\u003c\/b\u003e \u003cb data-path-to-node=\"15,7,0\" data-index-in-node=\"23\"\u003e2,700 ppm\u003c\/b\u003e to \u003cb data-path-to-node=\"15,7,0\" data-index-in-node=\"34\"\u003e3,400 ppm\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eCompatibility and Application Limits\u003c\/h3\u003e\n\u003cp data-path-to-node=\"17\"\u003eThe \u003cb data-path-to-node=\"17\" data-index-in-node=\"3\"\u003eHayward TurboCell\u003c\/b\u003e is compatible with all \u003cstrong\u003eAquaRite\u003c\/strong\u003e, \u003cstrong\u003eAquaRite Pro\u003c\/strong\u003e, and \u003cstrong\u003eSwimPure Plus\u003c\/strong\u003e systems. For optimal performance, it must be installed in the last section of the return pipe, after the filter and the heating system.\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cb data-path-to-node=\"17\" data-index-in-node=\"236\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e It should not operate with salt levels below \u003cb data-path-to-node=\"17\" data-index-in-node=\"304\"\u003e2,500 ppm\u003c\/b\u003e or above \u003cb data-path-to-node=\"17\" data-index-in-node=\"328\"\u003e4,500 ppm\u003c\/b\u003e, as this may reduce the service life of the electrodes. Do not clean the plates with metal tools; use only diluted acid solutions according to the technical manual.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"18\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"0\"\u003eWhy should I buy the original Hayward TurboCell instead of a compatible one?\u003c\/b\u003e Only the \u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"88\"\u003eHayward TurboCell\u003c\/b\u003e guarantees proper communication with your AquaRite system's microprocessor. Compatible cells often provide erroneous salt readings and have up to \u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"286\"\u003e50%\u003c\/b\u003e less durability due to the low quality of the plate coating.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"0\"\u003eHow do I know when it is time to replace my TurboCell?\u003c\/b\u003e Your system will display a \"Check Cell\" or \"Inspect Cell\" warning. If, after an acid cleaning, the chlorine production level does not recover or the system indicates \"Low Salt\" despite having sufficient salt, the cell's electrodes have reached the end of their operational life.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"0\"\u003eCan I install a T-CELL-15 in a small pool so it lasts longer?\u003c\/b\u003e Yes. This is a recommended engineering practice. By using a higher-capacity \u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"131\"\u003eHayward TurboCell\u003c\/b\u003e, the system runs for fewer hours to produce the same amount of chlorine, significantly extending the component's service life in years.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"20\"\u003eQ-Tech Engineering Support\u003c\/h3\u003e\n\u003cp data-path-to-node=\"21\"\u003eAt Q-tech.es, we provide specialized technical assistance for the configuration of IT\/OT water treatment systems. If you require support for diagnosing your chlorinator or on-site assistance for replacing your \u003cb data-path-to-node=\"21\" data-index-in-node=\"225\"\u003eHayward TurboCell\u003c\/b\u003e, contact our team of field engineers.\u003c\/p\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: 24px; top: 169.062px;\"\u003e\n\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"Hayward","offers":[{"title":"T-Cell-3-E cell","offer_id":56933958648152,"sku":"SCP-HAY-450-1209","price":559.0,"currency_code":"EUR","in_stock":true},{"title":"T-Cell-9-E cell","offer_id":56933958680920,"sku":"SCP-450-1210","price":695.0,"currency_code":"EUR","in_stock":true},{"title":"T-Cell-15-E Cell","offer_id":56933958713688,"sku":"SCP-HAY-450-1208","price":882.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/CELULA-TURBOCELL-CLORADOR-AQUARITE-HAYWARD-00.webp?v=1773921712"}],"url":"https:\/\/q-tech.es\/en\/collections\/salt-chlorinator-cells.oembed","provider":"Q-Tech ® ","version":"1.0","type":"link"}