{"title":"SEKO probes","description":"\u003cp class=\"qt-version\"\u003eFP54·261111\u003c\/p\u003e","products":[{"product_id":"electrodo-ph-sph-1-s-seko","title":"SEKO SPH-1-S pH electrode","description":"\u003cp\u003eSEKO pH electrode model SPH-1-S, 5 m\u003c\/p\u003e\n\u003ch3\u003eFeatures:\u003c\/h3\u003e\n\u003cp\u003e- Original replacement pH electrode for dosing pumps such as Avady's pH PRIM. \u003c\/p\u003e\n\u003cp\u003e- Replace the worn pH sensor with this official spare part and control your pool's pH with maximum precision again.\u003c\/p\u003e\n\u003cp\u003e- For accurate readings, it is important to prevent air from entering and to place the measuring electrode in the flow line first, followed by the product injection connection.\u003c\/p\u003e\n\u003cp\u003e\n\u003cstrong\u003e- Features a 5-metre cable.\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e- BNC connection\u003c\/p\u003e\n\u003cp\u003eNOTE: electrodes are consumables and cannot be returned. \u003c\/p\u003e\n\u003ch3\u003e\n\u003c\/h3\u003e\n\u003cp class=\"qt-nota-stock\"\u003e\u003cstrong\u003eAvailability and delivery times:\u003c\/strong\u003e this item is in stock at our warehouse. Occasionally, depending on the time of year, an error may occur in the stock update. If there are no units available at the time of your order, we will order it urgently and inform you immediately of the updated delivery time.\u003c\/p\u003e","brand":"SEKO","offers":[{"title":"1.5 m cable","offer_id":55049773678936,"sku":"SCP-SEK-451-0042","price":69.0,"currency_code":"EUR","in_stock":true},{"title":"5 m cable","offer_id":55049773711704,"sku":"SCP-SEK-451-0036","price":86.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/seko-electrodo-ph-sph-1-s-seko-default-title-52965672452440.jpg?v=1702917008"},{"product_id":"electrodo-rx-srh-1-s-seko","title":"SEKO RX SRH-1-S Electrode","description":"\u003ch3\u003eSEKO SRH-1-S Redox Electrode\u003c\/h3\u003e\n\u003ch4\u003eFeatures:\u003c\/h4\u003e\n\u003cp\u003e- Original redox electrode replacement for dosing pumps such as the Avady RX. \u003c\/p\u003e\n\u003cp\u003e- Replace the worn redox sensor with this official spare part and regain control over your pool's redox with maximum precision.\u003c\/p\u003e\n\u003cp\u003e- For accurate readings, it is important to prevent air from entering and to place the measuring electrode in the flow line first, followed by the chemical injection connection.\u003c\/p\u003e\n\u003cp\u003e\n\u003cstrong\u003e- Cable: 1.5m and 5m.\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e- BNC connection\u003c\/p\u003e\n\u003cp\u003eNOTE: electrodes are consumables and are not eligible for return. \u003c\/p\u003e\n\u003ch3\u003e\n\n\u003cbr\u003e\n\n\u003c\/h3\u003e\n\u003cp class=\"qt-nota-stock\"\u003e\u003cstrong\u003eAvailability and lead times:\u003c\/strong\u003e this item is in stock at our warehouse. Occasionally, depending on the time of year, an error may occur in the stock update. If there are no units available at the time of your order, we will order them urgently and inform you immediately of the updated delivery time.\u003c\/p\u003e\n","brand":"SEKO","offers":[{"title":"1.5 m cable","offer_id":55050162798936,"sku":"SCP-SEK-451-0043","price":69.0,"currency_code":"EUR","in_stock":true},{"title":"5 m cable","offer_id":55050162831704,"sku":"SCP-SEK-451-0037","price":69.0,"currency_code":"EUR","in_stock":true},{"title":"5 m cable (gold filament)","offer_id":55050301145432,"sku":"SCP-SEK-451-0079","price":189.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/ELECTRODO-RX-SEKO-SRH-1-S-00.webp?v=1749489608"},{"product_id":"vaso-portaelectrodo-3-sondas-pss8-seko","title":"PSS8 SEKO 3-probe electrode holder","description":"\u003ch3 data-path-to-node=\"6\"\u003eSEKO PSS8: Electrode Holder for Three Analytical Probes\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-path-to-node=\"7\" data-index-in-node=\"3\"\u003eSEKO PSS8 3-Probe Electrode Holder\u003c\/b\u003e is a hydraulic measurement chamber designed to stabilize chemical sensor readings. This device centralizes up to three electrodes in a single derived flow, optimizing the accuracy of automatic controllers. The cost of inaction when installing probes directly in the main pipe includes erratic readings due to turbulence, premature wear from direct pressure, and mechanical breakage during water flow. The \u003cb data-path-to-node=\"7\" data-index-in-node=\"485\"\u003eSEKO PSS8\u003c\/b\u003e addresses these operational risks through a bypass design that isolates and protects the chemical sensors.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\n\n\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eHydraulic Stabilization and Analytical Signal Centralization\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-path-to-node=\"9\" data-index-in-node=\"3\"\u003eSEKO PSS8 3-Probe Electrode Holder\u003c\/b\u003e stands out for its fluid conditioning capability for electrochemical instrumentation. Its internal architecture reduces water velocity in a controlled manner, ensuring homogeneous and continuous contact with the sensitive membranes of the electrodes.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\n\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eSimultaneous Triple Capacity:\u003c\/b\u003e It houses a maximum of \u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"48\"\u003e3 analytical probes\u003c\/b\u003e, allowing the joint measurement of parameters such as pH, Redox (ORP), conductivity, or temperature.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\n\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eIndustrial Bypass Design:\u003c\/b\u003e It allows a fraction of the flow to be diverted from the filtration circuit, facilitating calibration and cleaning tasks without stopping the main pumping.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\n\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eHigh-Resistance Translucent Body:\u003c\/b\u003e Made of technical polymers that allow direct visual inspection of the cleanliness of the electrodes and the presence of bubbles.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\n\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eIntegrated Quick Connections:\u003c\/b\u003e It incorporates inlet and outlet fittings designed for standard instrumentation tubing, minimizing potential leak points.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003e\n\n\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Specifications\u003c\/b\u003e\n\n\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,0,0\"\u003e\n\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eDevice Model:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"23\"\u003ePSS8\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,1,0\"\u003e\n\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eInstrumentation Capacity:\u003c\/b\u003e \u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"30\"\u003e3 electrodes\u003c\/b\u003e or analytical probes of standard diameter.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,2,0\"\u003e\n\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eHydraulic Connection Type:\u003c\/b\u003e Quick connectors for instrumentation tubing.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,3,0\"\u003e\n\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure:\u003c\/b\u003e \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"27\"\u003e5 bar\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,4,0\"\u003e\n\u003cb data-path-to-node=\"12,4,0\" data-index-in-node=\"0\"\u003eMaximum Operating Temperature:\u003c\/b\u003e \u003cb data-path-to-node=\"12,4,0\" data-index-in-node=\"30\"\u003e50 °C\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,5,0\"\u003e\n\u003cb data-path-to-node=\"12,5,0\" data-index-in-node=\"0\"\u003eBody Material:\u003c\/b\u003e Translucent polymer with industrial chemical resistance.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,6,0\"\u003e\n\u003cb data-path-to-node=\"12,6,0\" data-index-in-node=\"0\"\u003eFlow Configuration:\u003c\/b\u003e Mandatory installation in a bypass (\u003cb data-path-to-node=\"12,6,0\" data-index-in-node=\"63\"\u003eBypass\u003c\/b\u003e).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\n\n\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eCompatibility and Hydraulic Installation Protocols\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"14\"\u003eThe \u003cb data-path-to-node=\"14\" data-index-in-node=\"3\"\u003eSEKO PSS8 3-Probe Electrode Holder\u003c\/b\u003e is compatible with all probe brands with a standard connection of \u003cb data-path-to-node=\"14\" data-index-in-node=\"112\"\u003e12 mm\u003c\/b\u003e in diameter. It must be installed in a vertical section of the technical room, using the bypass taps after the filter and before chemical injection. \u003cb data-path-to-node=\"14\" data-index-in-node=\"275\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not exceed the nominal pressure of \u003cb data-path-to-node=\"14\" data-index-in-node=\"329\"\u003e5 bar\u003c\/b\u003e or the temperature of \u003cb data-path-to-node=\"14\" data-index-in-node=\"356\"\u003e50 °C\u003c\/b\u003e. The chamber must not receive the direct impact of concentrated chemicals. It is mandatory to clean the chamber periodically to prevent deposits that alter the response time of the sensors.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"15\"\u003e\n\n\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003eFrequently Asked Questions\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"16,0,0\"\u003e\n\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"0\"\u003eWhat advantages does using the PSS8 electrode holder offer compared to traditional collars?\u003c\/b\u003e The \u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"92\"\u003eSEKO PSS8\u003c\/b\u003e isolates the sensors from the turbulence of the main pipe. By controlling the water flow, pH and Redox readings are more stable. In addition, it allows the probes to be removed for calibration without interrupting filtration.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"16,1,0\"\u003e\n\u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"0\"\u003eIs this electrode holder compatible with probes from other brands?\u003c\/b\u003e Yes. The design of the taps of the \u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"100\"\u003eSEKO PSS8\u003c\/b\u003e accepts any standard probe on the market with a body diameter of \u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"183\"\u003e12 mm\u003c\/b\u003e. This includes sensors from brands such as Sugar Valley, Hayward, Zodiac, or AstralPool.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"16,2,0\"\u003e\n\u003cb data-path-to-node=\"16,2,0\" data-index-in-node=\"0\"\u003eWhy is it necessary to install this component in a bypass circuit?\u003c\/b\u003e Installation in bypass reduces the pressure and flow that impact the probes. This extends the life of the glass membranes and allows the exact flow required by the sensor manufacturer to be regulated.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"17\"\u003e\n\n\u003cb data-path-to-node=\"17\" data-index-in-node=\"0\"\u003eQ-Tech Engineering Support\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"18\"\u003eAt Q-tech.es we provide specialized technical assistance for the design of control panels and hydraulic instrumentation. If you require support for the connection diagram of your \u003cb data-path-to-node=\"18\" data-index-in-node=\"182\"\u003eSEKO PSS8 3-Probe Electrode Holder\u003c\/b\u003e or consulting for automation projects, contact our field engineers.\u003c\/p\u003e\n\u003cp class=\"qt-nota-stock\"\u003e\u003cstrong\u003eAvailability and lead times:\u003c\/strong\u003e this item is in stock in our warehouse. Occasionally, depending on the time of year, an error in the stock update may occur. If there are no units available at the time of your order, we will order it urgently and inform you immediately of the updated delivery time.\u003c\/p\u003e\n","brand":"SEKO","offers":[{"title":"Default Title","offer_id":57444254679384,"sku":"SCP-SEK-451-0019","price":198.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/SEKO-VASO-TRIPLE-PORTAELECTRODOS-PSS8_1be2b1d2-2ed9-4ce3-8d8e-23984cfed19f.webp?v=1780578217"}],"url":"https:\/\/q-tech.es\/en-int\/collections\/seko-ph-probes.oembed","provider":"Q-Tech ® ","version":"1.0","type":"link"}