{"title":"Filtration accessories","description":"At Q-Tech, we offer all the necessary accessories for your pool filtration equipment: manual and automatic selector valves, safety valves, and filtration-saving accessories. Everything you need to complete your filter.","products":[{"product_id":"hydrospin-prefiltro-hidrociclonico-astralpool-45289","title":"Hydrospin - AstralPool hydrocyclonic pre-filter 45289","description":"\u003cp\u003eHydrocyclone pre-filter for cleaning that can be installed in filtration systems in both new and existing installations.\u003c\/p\u003e\n\u003cp\u003eIt is installed between the pump and the filter, separating solids down to 40 microns, thereby reducing the filtration system's backwash water consumption by half.\u003c\/p\u003e\n\u003cp\u003eThe HydroSpin has a solid collection tank with 3 distinct zones (sedimentation, clarification, and thickening).\u003c\/p\u003e\n\u003cp\u003eIt can be cleaned with just 5 liters of water without the need to stop the pump.\u003c\/p\u003e\n\u003ch3\u003eFeatures:\u003c\/h3\u003e\n\u003cp\u003e- Significant reduction in filter wash operations.\u003c\/p\u003e\n\u003cp\u003e- Low pressure losses, allowing installation without the need to replace the existing pump.\u003c\/p\u003e\n\u003cp\u003e- Can be installed on the floor with the supplied accessories or on the wall using DN300 flanges.\u003c\/p\u003e\n\u003cp\u003e- Standard Ø63mm connections for water inlet and outlet, and Ø32mm for waste discharge.\u003c\/p\u003e\n\u003cp\u003e- Minimum flow rate: 5 m3\/h.\u003c\/p\u003e\n\u003cp\u003e- Maximum flow rate: 30 m3\/h.\u003c\/p\u003e\n\u003cp\u003e- Allows treatment of flow rates up to 30m³\/h with a maximum working pressure of 2.5 bar.\u003c\/p\u003e\n\u003cp\u003e- Included items: HydroSpin, support ring, support structure, and 1\" drain valve.\u003c\/p\u003e\n\u003cp\u003e- Dimensions: 820 x Ø300 mm\u003c\/p\u003e\n\u003cp\u003e- WARRANTY: 2 years.\u003c\/p\u003e\n\u003ch3\u003eVideo:\u003c\/h3\u003e\n\u003cp\u003e\n\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/ZQnW70sdFww\"\u003e\n\u003c\/iframe\u003e\n\u003cbr\u003e\n\u003c\/p\u003e\n\u003cp class=\"qt-nota-stock\"\u003e\u003cstrong\u003eAvailability and lead times:\u003c\/strong\u003e this item is in stock at our warehouse. Occasionally, depending on the time of year, an error may occur in the stock update. If there are no units available at the time of your order, we will order it urgently and inform you immediately of the updated delivery time.\u003c\/p\u003e\n","brand":"AstralPool","offers":[{"title":"Default Title","offer_id":12317512925272,"sku":"AS45289","price":449.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/astralpool-hydrospin-prefiltro-hidrociclonico-astralpool-45289-default-title-52965334614360.jpg?v=1702914730"},{"product_id":"caudalimetro-flowvis","title":"FlowVis® Flow Meter","description":"\u003ch3 data-path-to-node=\"6\"\u003eFlowVis®: Certified Precision Flow Measurement Engineering\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-path-to-node=\"7\" data-index-in-node=\"3\"\u003eFlowVis®\u003c\/b\u003e is the most accurate and reliable flow meter designed for water treatment and pool systems. This device combines a high-visibility flow indicator with an integrated check valve, ensuring exact monitoring of hydraulic performance. Inaction in flow measurement leads to inefficient filtration, energy waste, and failures in automated disinfection systems. The \u003cb data-path-to-node=\"7\" data-index-in-node=\"434\"\u003eFlowVis®\u003c\/b\u003e solves these operational risks through real-time readings with \u003cb data-path-to-node=\"7\" data-index-in-node=\"536\"\u003e97.9%\u003c\/b\u003e accuracy, enabling the optimization of variable speed pumps.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eFlow Monitoring and Energy Efficiency\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-path-to-node=\"9\" data-index-in-node=\"3\"\u003eFlowVis®\u003c\/b\u003e uses a calibrated scale design that does not require straight lengths of pipe before or after its installation. This technology allows you to know the exact flow rate to adjust pump RPMs and maximize operational energy savings (OPEX).\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eNSF Certified Accuracy:\u003c\/b\u003e The only flow meter on the market with \u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"83\"\u003eNSF 50\u003c\/b\u003e certification, guaranteeing exact readings across the entire flow range.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eOperational Duality:\u003c\/b\u003e Functions simultaneously as a flow meter and a high-reliability check valve, saving space and installation costs.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eFiltration Optimization:\u003c\/b\u003e Facilitates the adjustment of the flow velocity required for advanced filter media such as AFM, improving water biosecurity.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eError-Free Reading:\u003c\/b\u003e Easy-to-read scale in \u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"48\"\u003em3\/h\u003c\/b\u003e or \u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"55\"\u003eGPM\u003c\/b\u003e that is not affected by air accumulation or internal turbulence.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eMechanical Robustness and Hydraulic Safety\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003eThe architecture of the \u003cb data-path-to-node=\"12\" data-index-in-node=\"20\"\u003eFlowVis®\u003c\/b\u003e is designed for continuous operation in demanding chemical conditions. Its robust design avoids the mechanical failures common in turbine or float-type flow meters, ensuring extended service life without the need for frequent calibrations.\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eIndustrial-Grade Materials:\u003c\/b\u003e Manufactured with corrosion-resistant components, compatible with saltwater chlorination systems and intensive chemical disinfection.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eVersatile Installation:\u003c\/b\u003e Its unique design allows it to be installed in any position (vertical, horizontal, or inverted) and directly after elbows or valves.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eZero Maintenance:\u003c\/b\u003e It has no internal gears or electronic components that require a power supply or periodic spare parts.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eIntegrated Check Valve:\u003c\/b\u003e Protects technical room equipment against water backflow and water hammer mechanically and automatically.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"14\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eReading Accuracy:\u003c\/b\u003e \u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"22\"\u003e97.9%\u003c\/b\u003e (NSF 50 certification).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eAvailable Models:\u003c\/b\u003e DN40, DN50, DN65, DN80, and DN100.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eUnits of Measurement:\u003c\/b\u003e \u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"20\"\u003em3\/h\u003c\/b\u003e (Cubic meters per hour) and GPM.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eSpring Material:\u003c\/b\u003e High-strength stainless steel.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,4,0\"\u003e\u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure:\u003c\/b\u003e \u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"27\"\u003e3.5 bar\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,5,0\"\u003e\u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"0\"\u003eOperating Temperature:\u003c\/b\u003e 0 to 50 °C.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,6,0\"\u003e\u003cb data-path-to-node=\"15,6,0\" data-index-in-node=\"0\"\u003eChemical Compatibility:\u003c\/b\u003e Suitable for freshwater, saltwater, and ozone systems.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,7,0\"\u003e\u003cb data-path-to-node=\"15,7,0\" data-index-in-node=\"0\"\u003eCertifications:\u003c\/b\u003e \u003cb data-path-to-node=\"15,7,0\" data-index-in-node=\"17\"\u003eNSF\/ANSI 50\u003c\/b\u003e for pools, spas, and public spas.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eCompatibility and Application Limits\u003c\/h3\u003e\n\u003cp data-path-to-node=\"17\"\u003eThe \u003cb data-path-to-node=\"17\" data-index-in-node=\"3\"\u003eFlowVis®\u003c\/b\u003e is compatible with all standard pressure PVC pipes. The model corresponding to the pipe's outer diameter must be selected to avoid hydraulic bottlenecks.\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cb data-path-to-node=\"17\" data-index-in-node=\"201\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not use in systems with pressures exceeding \u003cb data-path-to-node=\"17\" data-index-in-node=\"273\"\u003e3.5 bar\u003c\/b\u003e. Ensure that the flow indicator arrow matches the actual direction of the water during assembly to prevent damage to the internal mechanism.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"18\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"0\"\u003eWhy is the FlowVis® more reliable than other flow meters?\u003c\/b\u003e Unlike turbine models, the \u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"103\"\u003eFlowVis®\u003c\/b\u003e does not get blocked by small particles and does not lose accuracy over time. Its calibrated spring-based design allows for an exact reading without needing long straight pipe lengths.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"0\"\u003eHow does the FlowVis® help save money on my electric bill?\u003c\/b\u003e By knowing the actual flow rate in \u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"95\"\u003em3\/h\u003c\/b\u003e, you can reduce your pump speed to the minimum required for effective filtration. Without the \u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"201\"\u003eFlowVis®\u003c\/b\u003e, most pumps operate at excessive speeds, wasting up to 50% of energy.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"0\"\u003eCan the FlowVis® be installed next to a 90-degree elbow?\u003c\/b\u003e Yes. The patented design of the \u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"89\"\u003eFlowVis®\u003c\/b\u003e compensates for turbulence. This allows it to be installed directly after an elbow or a pump without affecting measurement accuracy, something impossible for other flow meters.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"20\"\u003eQ-Tech Engineering Support\u003c\/h3\u003e\n\u003cp data-path-to-node=\"21\"\u003eAt Q-tech.es, we provide specialized technical assistance for the hydraulic optimization of critical installations. If you require support for \u003cb data-path-to-node=\"21\" data-index-in-node=\"169\"\u003eFlowVis®\u003c\/b\u003e sizing or an energy efficiency audit for your B2B system, contact our field engineers by phone or in person.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/Captura_de_pantalla_2024-04-23_a_las_13.28.38_600x600.png?v=1713871743\" alt=\"FlowVis® simple installation\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/l0BijcLMheE?si=LKolFvq8aCzXbYs6\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical documentation:\u003c\/h4\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"FlowVis pool flow meter installation manual\" href=\"https:\/\/www.h2floweurope.com\/wp-content\/uploads\/2021\/02\/FlowVis-Manual-Rev4.9EUR.pdf\" target=\"_blank\"\u003eInstallation manual\u003c\/a\u003e\u003c\/p\u003e","brand":"FlowVis","offers":[{"title":"FlowVis flow meter DN40 (50mm glue) with check valve - 2.4-21 m3\/h","offer_id":48150950576472,"sku":"PS-13400","price":245.0,"currency_code":"EUR","in_stock":true},{"title":"FlowVis Flow Meter DN50 (63mm solvent weld) with check valve - 2.4-24 m3\/h","offer_id":48150950642008,"sku":"PS-13401","price":245.0,"currency_code":"EUR","in_stock":true},{"title":"FlowVis flow meter DN65 (75mm external glue) - 7-45 m3\/h","offer_id":48169777135960,"sku":"PS-17333","price":245.0,"currency_code":"EUR","in_stock":true},{"title":"FlowVis Flow Meter DN80 (90mm glue-in) - 16-54 m3\/h","offer_id":48169783263576,"sku":"PS-13403","price":715.0,"currency_code":"EUR","in_stock":true},{"title":"FlowVis DN100 Flow Meter (110mm solvent weld) - 27-102 m3\/h","offer_id":48169788342616,"sku":"PS-13404","price":729.0,"currency_code":"EUR","in_stock":true},{"title":"FlowVis Flow Meter DN150 (160mm solvent weld) - 68-227 m3\/h","offer_id":48169801220440,"sku":"PS-17329","price":879.0,"currency_code":"EUR","in_stock":true},{"title":"FlowVis Flow Meter DN150 (160mm with collar) - 68-227 m3\/h","offer_id":48169809150296,"sku":"PS-23872","price":955.0,"currency_code":"EUR","in_stock":true},{"title":"FlowVis Flow Meter DN185 (200mm solvent weld) - 113-420 m3\/h","offer_id":48169824682328,"sku":"PS-17330","price":999.0,"currency_code":"EUR","in_stock":true},{"title":"FlowVis DN185 Flow Meter (200mm with collar) - 113-420 m3\/h","offer_id":48169835528536,"sku":"PS-23873","price":1100.0,"currency_code":"EUR","in_stock":true},{"title":"FlowVis digital display for all models","offer_id":48169841623384,"sku":"PS-17331","price":955.0,"currency_code":"EUR","in_stock":true},{"title":"8m cable extension for FlowVis display","offer_id":48169847357784,"sku":"PS-17332","price":235.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/FLOWVIS-CAUDALIMETRO-CAUDAL-PISCINA-00.webp?v=1713872996"},{"product_id":"mezclador-estatico-zpm-dryden-aqua-potencial-zeta","title":"ZPM static mixer","description":"\u003ch3 data-path-to-node=\"6\"\u003eDryden Aqua ZPM: Flocculation Engineering and Mechanical Disinfection\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-path-to-node=\"7\" data-index-in-node=\"3\"\u003eDryden Aqua ZPM\u003c\/b\u003e is a stainless steel static mixer designed to optimize water treatment by amplifying the Zeta potential. This device performs instantaneous mixing of reagents and hydrodynamic cavitation to neutralize the charge of colloidal particles. Inaction in conventional filtration systems allows pathogens and microplastics to pass through the filter bed. The \u003cb data-path-to-node=\"7\" data-index-in-node=\"428\"\u003eDryden Aqua ZPM\u003c\/b\u003e solves this technical risk through mechanical flocculation and physical disinfection, ensuring biologically safe water with reduced chemical use.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eZeta Potential Optimization and Hydrodynamic Cavitation\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-path-to-node=\"9\" data-index-in-node=\"3\"\u003eDryden Aqua ZPM\u003c\/b\u003e uses internal vanes to generate high-energy turbulence. This physical process reduces the electrical charge of suspended particles, allowing flocculants to act with \u003cb data-path-to-node=\"9\" data-index-in-node=\"227\"\u003e100%\u003c\/b\u003e efficiency before reaching the filter.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\n\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eCavitation Disinfection:\u003c\/b\u003e The controlled pressure drop generates vacuum bubbles that collapse and destroy the cell membranes of bacteria and parasites.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\n\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eInstantaneous Reagent Mixing:\u003c\/b\u003e Ensures a homogeneous distribution of coagulants and flocculants in the water flow, eliminating chemical waste.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\n\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eEfficient Mechanical Flocculation:\u003c\/b\u003e Groups fine particles and colloids into large flocs that are easily retained by the AFM filter medium.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\n\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003ePassive Component Without Consumption:\u003c\/b\u003e Static device made of stainless steel that does not require an electrical supply or mechanical maintenance.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eChemical Robustness and Critical Engineering Standards\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003eThe manufacturing of the \u003cb data-path-to-node=\"12\" data-index-in-node=\"19\"\u003eDryden Aqua ZPM\u003c\/b\u003e in high-quality stainless steel ensures total resistance to corrosion and attack by concentrated chemicals. Its design is projected to operate continuously in the most demanding technical rooms.\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,0,0\"\u003e\n\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eAISI 316L Stainless Steel:\u003c\/b\u003e Industrial-grade material that resists oxidation and guarantees the purity of the treated water.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,1,0\"\u003e\n\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eCentral Reagent Injection:\u003c\/b\u003e It has injection ports that introduce the chemical into the core of the turbulence for an immediate chemical reaction.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,2,0\"\u003e\n\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eIntegrated Grounding:\u003c\/b\u003e Includes a ground connection terminal to eliminate static electricity and protect the galvanic integrity of the piping network.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,3,0\"\u003e\n\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eQuality Certification:\u003c\/b\u003e Component designed under European standards for IT\/OT integration in high-level water management systems.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"14\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,0,0\"\u003e\n\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eManufacturing Material:\u003c\/b\u003e \u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"42\"\u003eAISI 316L\u003c\/b\u003e stainless steel.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,1,0\"\u003e\n\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003ePressure Drop:\u003c\/b\u003e Less than \u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"31\"\u003e0.1 bar\u003c\/b\u003e (under nominal flow conditions).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,2,0\"\u003e\n\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eInjection Ports:\u003c\/b\u003e \u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"36\"\u003e1\/2 inch\u003c\/b\u003e connections for chemical dosing.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,3,0\"\u003e\n\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eHydraulic Connections:\u003c\/b\u003e Flanges or threads depending on diameter (from \u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"62\"\u003eDN40\u003c\/b\u003e to \u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"73\"\u003eDN300\u003c\/b\u003e).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,4,0\"\u003e\n\u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure:\u003c\/b\u003e \u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"27\"\u003e10 bar\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,5,0\"\u003e\n\u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"0\"\u003eFunctionality:\u003c\/b\u003e Static mixing, cavitation, and mechanical flocculation.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,6,0\"\u003e\n\u003cb data-path-to-node=\"15,6,0\" data-index-in-node=\"0\"\u003eChemical Compatibility:\u003c\/b\u003e Resistant to common flocculants, coagulants, and oxidants.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eCompatibility and Application Limits\u003c\/h3\u003e\n\u003cp data-path-to-node=\"17\"\u003eThe \u003cb data-path-to-node=\"17\" data-index-in-node=\"3\"\u003eDryden Aqua ZPM\u003c\/b\u003e must always be installed before filtration for flocculation, or after the filter to enhance disinfection. Its joint use with the \u003cb data-path-to-node=\"17\" data-index-in-node=\"193\"\u003eAFM\u003c\/b\u003e filter medium is recommended to maximize transparency and biosecurity results. \u003cb data-path-to-node=\"17\" data-index-in-node=\"260\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not install the equipment in piping sections with extreme mechanical vibrations. The sizing must be adjusted to the water flow velocity to ensure cavitation; a velocity that is too low nullifies the mechanical disinfection effect.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"18\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,0,0\"\u003e\n\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"0\"\u003eWhere exactly should the Dryden Aqua ZPM be installed?\u003c\/b\u003e To optimize filtration, install the \u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"97\"\u003eDryden Aqua ZPM\u003c\/b\u003e between the pump and the filter. To enhance disinfection with chlorine or ozone, install a second unit after the filter to ensure a homogeneous and safe mixture.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,1,0\"\u003e\n\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"0\"\u003eDoes the Dryden Aqua ZPM require any type of maintenance?\u003c\/b\u003e No. Being a static mixer without moving parts, the \u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"114\"\u003eDryden Aqua ZPM\u003c\/b\u003e does not suffer mechanical wear. It only requires an annual visual inspection to ensure that the chemical injection points do not have obstructions from scale buildup.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,2,0\"\u003e\n\u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"0\"\u003eIs it necessary to connect the equipment to the ground?\u003c\/b\u003e Yes. The ground connection is critical to neutralize the electrical potential generated by the water flow. This protects the installation against galvanic corrosion and improves the efficiency of mechanical particle flocculation.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"20\"\u003eQ-Tech Engineering Support\u003c\/h3\u003e\n\u003cp data-path-to-node=\"21\"\u003eAt Q-tech.es we provide technical consulting for the design of high-efficiency water treatment systems. If you require support for the sizing of the \u003cb data-path-to-node=\"21\" data-index-in-node=\"167\"\u003eDryden Aqua ZPM\u003c\/b\u003e or its integration into an HVAC or industrial process project, contact our field engineers.\u003c\/p\u003e\n\u003cp class=\"qt-nota-stock\"\u003e\u003cstrong\u003eAvailability and deadlines:\u003c\/strong\u003e we have this item in stock in our warehouse. Occasionally, depending on the time of year, an error in the stock update may occur. If no units are available at the time of your order, we will order it urgently and inform you immediately of the updated delivery time.\u003c\/p\u003e\n","brand":"Dryden Aqua","offers":[{"title":"ZPM DN 40 - 1 1\/2\" in.","offer_id":56884078248280,"sku":"PS-11239","price":225.0,"currency_code":"EUR","in_stock":true},{"title":"ZPM DN 50 - 2\" flanged","offer_id":56884078281048,"sku":"PS-9425","price":280.0,"currency_code":"EUR","in_stock":true},{"title":"ZPM DN 65 - 2 1\/2\" enc","offer_id":56884078313816,"sku":"PS-14631","price":650.0,"currency_code":"EUR","in_stock":true},{"title":"ZPM DN 80 - 3\" flange","offer_id":56884078346584,"sku":"PS-14633","price":850.0,"currency_code":"EUR","in_stock":true},{"title":"ZPM DN 100 - 4\" flange","offer_id":56884078379352,"sku":"PS-14634","price":980.0,"currency_code":"EUR","in_stock":true},{"title":"ZPM DN 125 - 5\" flange","offer_id":56884430209368,"sku":"PS-14635","price":1450.0,"currency_code":"EUR","in_stock":true},{"title":"ZPM DN 150 - 6\" flange","offer_id":56884432011608,"sku":"PS-14636","price":1990.0,"currency_code":"EUR","in_stock":true},{"title":"ZPM DN 200 - 8\" flanged","offer_id":56884434534744,"sku":"PS-28297","price":2850.0,"currency_code":"EUR","in_stock":true},{"title":"ZPM DN 250 - 10\" flange","offer_id":56884438073688,"sku":"PS-28298","price":3990.0,"currency_code":"EUR","in_stock":true},{"title":"ZPM DN 300 - 12\" flange","offer_id":56884441448792,"sku":"PS-36353","price":4590.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/ZPM-ZETA-POTENCIAL-MIXER-DRYDEN-CONTROL-PISCINA-00.webp?v=1773226426"},{"product_id":"tapa-transparente-caudalimetro-flowvis®","title":"FlowVis® Flow Meter Transparent Lid","description":"\u003ch3 data-path-to-node=\"6\"\u003eFlowVis® Flowmeter Transparent Cover\u003c\/h3\u003e\n\u003cp\u003eReplacement transparent cover for Flowvis® flowmeter.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp class=\"qt-nota-stock\"\u003e\u003cstrong\u003eAvailability and lead times:\u003c\/strong\u003e this item is in stock in our warehouse. Occasionally, depending on the time of year, an error may occur in the stock update. If there are no units available at the time of your order, we would order it urgently and inform you immediately of the updated delivery time.\u003c\/p\u003e\n","brand":"FlowVis","offers":[{"title":"Transparent lid Ø50mm","offer_id":57787035517272,"sku":"PS-28477","price":102.0,"currency_code":"EUR","in_stock":true},{"title":"Transparent lid Ø63\/75mm","offer_id":57787035550040,"sku":"PS-26483","price":98.0,"currency_code":"EUR","in_stock":true},{"title":"Transparent lid Ø90mm","offer_id":57787035582808,"sku":"PS-28532","price":429.0,"currency_code":"EUR","in_stock":true},{"title":"Transparent lid Ø110mm","offer_id":57787035615576,"sku":"PS-28533","price":435.0,"currency_code":"EUR","in_stock":true},{"title":"Transparent lid Ø160mm","offer_id":57787035648344,"sku":"PS-28547","price":435.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/FLOWVIS-RECAMBIO-TAPA-TRANSPARENTE-00.webp?v=1784806862"}],"url":"https:\/\/q-tech.es\/en-int\/collections\/accesorios-filtracion-piscina.oembed","provider":"Q-Tech ® ","version":"1.0","type":"link"}