{"product_id":"vaso-portaelectrodo-3-sondas-pss8-seko","title":"PSS8 SEKO 3-probe electrode holder","description":"\u003ch3 data-path-to-node=\"6\"\u003eSEKO PSS8: Electrode holder vessel for Three Analytical Probes\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-path-to-node=\"7\" data-index-in-node=\"3\"\u003eSEKO PSS8 3-probe electrode holder vessel\u003c\/b\u003e is a hydraulic measurement chamber designed to stabilize chemical sensor readings. This device centralizes up to three electrodes in a single bypass flow, optimizing the precision of automatic controllers. The cost of inaction when installing probes directly into the main pipeline includes erratic readings due to turbulence, premature wear from direct pressure, and mechanical breakage during water flow. The \u003cb data-path-to-node=\"7\" data-index-in-node=\"485\"\u003eSEKO PSS8\u003c\/b\u003e resolves these operational risks through a bypass design that isolates and protects the chemical sensors.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eHydraulic Stabilization and Analytical Signal Centralization\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-path-to-node=\"9\" data-index-in-node=\"3\"\u003eSEKO PSS8 3-probe electrode holder vessel\u003c\/b\u003e stands out for its fluid conditioning capacity for electrochemical instrumentation. Its internal architecture reduces water velocity in a controlled manner, ensuring homogeneous and continuous contact with the sensitive membranes of the electrodes.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eTriple Simultaneous Capacity:\u003c\/b\u003e Accommodates a maximum of \u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"48\"\u003e3 analytical probes\u003c\/b\u003e, allowing for the joint measurement of parameters such as pH, Redox (ORP), and conductivity or temperature.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eIndustrial Bypass Design:\u003c\/b\u003e Allows for diverting a fraction of the flow from the filtration circuit, facilitating calibration and cleaning tasks without stopping the main pump.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eHigh-Resistance Translucent Body:\u003c\/b\u003e Made of technical polymers that allow direct visual inspection of the cleanliness of the electrodes and the presence of bubbles.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eIntegrated Quick Connections:\u003c\/b\u003e Includes inlet and outlet fittings designed for standard instrumentation tubing, minimizing potential leak points.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eDevice Model:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"23\"\u003ePSS8\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eInstrumentation Capacity:\u003c\/b\u003e \u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"30\"\u003e3 electrodes\u003c\/b\u003e or analytical probes of standard diameter.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eHydraulic Connection Type:\u003c\/b\u003e Quick connectors for instrumentation tubing.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eMaximum Operating Pressure:\u003c\/b\u003e \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"27\"\u003e5 bar\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,4,0\"\u003e\u003cb data-path-to-node=\"12,4,0\" data-index-in-node=\"0\"\u003eMaximum Operating Temperature:\u003c\/b\u003e \u003cb data-path-to-node=\"12,4,0\" data-index-in-node=\"30\"\u003e50 °C\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,5,0\"\u003e\u003cb data-path-to-node=\"12,5,0\" data-index-in-node=\"0\"\u003eBody Material:\u003c\/b\u003e Translucent polymer with industrial chemical resistance.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,6,0\"\u003e\u003cb data-path-to-node=\"12,6,0\" data-index-in-node=\"0\"\u003eFlow Configuration:\u003c\/b\u003e Mandatory installation in a \u003cb data-path-to-node=\"12,6,0\" data-index-in-node=\"63\"\u003eBypass\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eCompatibility and Hydraulic Installation Protocols\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"14\"\u003eThe \u003cb data-path-to-node=\"14\" data-index-in-node=\"3\"\u003eSEKO PSS8 3-probe electrode holder vessel\u003c\/b\u003e is compatible with all brands of probes with a standard \u003cb data-path-to-node=\"14\" data-index-in-node=\"112\"\u003e12 mm\u003c\/b\u003e diameter connection. It must be installed in a vertical section of the technical room, using the bypass taps after the filter and before the chemical injection. \u003cb data-path-to-node=\"14\" data-index-in-node=\"275\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not exceed the nominal pressure of \u003cb data-path-to-node=\"14\" data-index-in-node=\"329\"\u003e5 bar\u003c\/b\u003e or the temperature of \u003cb data-path-to-node=\"14\" data-index-in-node=\"356\"\u003e50 °C\u003c\/b\u003e. The vessel must not be directly impacted by concentrated chemical products. It is mandatory to clean the chamber periodically to prevent scaling that alters the response speed of the sensors.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"16,0,0\"\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"0\"\u003eWhat advantages does using the PSS8 electrode holder offer over traditional saddle clamps?\u003c\/b\u003e The \u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"92\"\u003eSEKO PSS8\u003c\/b\u003e isolates the sensors from the turbulence of the main pipeline. By controlling the water flow, the pH and Redox readings are more stable. Furthermore, it allows the probes to be extracted for calibration without interrupting filtration.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"16,1,0\"\u003e\u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"0\"\u003eIs this electrode holder vessel compatible with probes from other brands?\u003c\/b\u003e Yes. The design of the \u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"100\"\u003eSEKO PSS8\u003c\/b\u003e ports accepts any standard probe on the market with a body diameter of \u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"183\"\u003e12 mm\u003c\/b\u003e. This includes sensors from brands such as Sugar Valley, Hayward, Zodiac, or AstralPool.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"16,2,0\"\u003e\u003cb data-path-to-node=\"16,2,0\" data-index-in-node=\"0\"\u003eWhy is it necessary to install this component in a bypass circuit?\u003c\/b\u003e Installation in a bypass reduces the pressure and flow that impact the probes. This extends the service life of the glass membranes and allows for the regulation of the exact flow required by the sensor manufacturer.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"17\"\u003e\u003cb data-path-to-node=\"17\" data-index-in-node=\"0\"\u003eQ-Tech Engineering Support\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"18\"\u003eAt Q-tech.es we provide specialized technical assistance for the design of control panels and hydraulic instrumentation. If you require support for the connection scheme of your \u003cb data-path-to-node=\"18\" data-index-in-node=\"182\"\u003eSEKO PSS8 3-probe electrode holder vessel\u003c\/b\u003e or consulting for automation projects, contact our field engineers.\u003c\/p\u003e","brand":"SEKO","offers":[{"title":"Default Title","offer_id":57444254679384,"sku":"SCP-SEK-451-0019","price":233.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/SEKO-VASO-TRIPLE-PORTAELECTRODOS-PSS8_1be2b1d2-2ed9-4ce3-8d8e-23984cfed19f.webp?v=1780578217","url":"https:\/\/q-tech.es\/en-en\/products\/vaso-portaelectrodo-3-sondas-pss8-seko","provider":"Q-Tech ® ","version":"1.0","type":"link"}