{"product_id":"termostato-digital-f-100-osaka-para-refrigeracion-y-procesos-industriales","title":"Osaka F 100 Digital Thermostat for Refrigeration and Industrial Processes","description":"\u003cp\u003eThe \u003cb\u003eOsaka F 100 Digital Thermostat\u003c\/b\u003e is a high-performance electronic microprocessor controller designed for temperature regulation in \u003cb\u003erefrigeration and industrial process applications\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp\u003eThis thermostat offers precise temperature control via \u003cb\u003eON\/OFF\u003c\/b\u003e regulation and advanced defrost management. Its functionality, combined with a high-capacity relay output (16A) and support for NTC\/PTC probes, makes it the expert solution for maintaining stable and safe operating conditions.\u003c\/p\u003e\n\u003ch3\u003e✨ Advanced Functionality and Operational Benefits (E-E-A-T)\u003c\/h3\u003e\n\u003cp\u003eThe Osaka F 100 ensures the precise control that industrial and refrigeration processes demand.\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cb\u003ePrecise and Reliable Control:\u003c\/b\u003e High-speed \u003cb\u003eON\/OFF\u003c\/b\u003e temperature regulation, ideal for systems requiring robust binary control.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eVersatile Defrost Management:\u003c\/b\u003e Support for defrosting by time cycles (compressor stop) or by electric heating\/hot gas, allowing for energy and operational optimization.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eCompressor Safety:\u003c\/b\u003e Includes integrated protection with \u003cb\u003estart-up delay\u003c\/b\u003e (anti-short cycle), extending the compressor's service life.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eIntegrated Acoustic Alarm:\u003c\/b\u003e Features an internal buzzer that emits acoustic signals for alarm warnings and during programming, improving safety and usability.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eWide Measuring Range:\u003c\/b\u003e Capable of measuring temperatures from -50 to 109°C, suitable for most industrial refrigeration and heating applications.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003e⚙️ Technical Characteristics and Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe F 100's electronics and connectivity capabilities are designed for professional integration.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eRegulation and Sensors\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eRegulation Principle:\u003c\/b\u003e ON\/OFF.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eDefrost Control:\u003c\/b\u003e Compressor stop at intervals, electric heating (resistance), or hot gas (cycle inversion).\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eSingle Probe Input:\u003c\/b\u003e Compatible with \u003cb\u003eNTC\u003c\/b\u003e (10kΩ at 25°C) or \u003cb\u003ePTC\u003c\/b\u003e (990Ω at 25°C) temperature probes.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cb\u003eElectrical Data and Display\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cb\u003ePower Options:\u003c\/b\u003e 100 to 240V AC or 12 to 24V (AC\/DC). \u003cb\u003eNote:\u003c\/b\u003e NTC probe included in both versions.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eControl Output:\u003c\/b\u003e 1 relay output at \u003cb\u003e16A\u003c\/b\u003e voltage.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eNominal Consumption:\u003c\/b\u003e 4A.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eFrequency:\u003c\/b\u003e 50\/60 Hz.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eDisplay:\u003c\/b\u003e 3-digit red (17.7 mm) with decimal point. Optional blue display available for some models (consult us).\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eProtection:\u003c\/b\u003e Overvoltage Category II, Class II.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\n\u003cp\u003e\u003cb\u003eProfessional Attention!\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor the correct installation and configuration of the Osaka F 100 Thermostat, we have \u003cb\u003eelectrical connection diagrams\u003c\/b\u003e and complete programming manuals available. Contact our \u003cb\u003eTechnical Support Service\u003c\/b\u003e if you need assistance with selecting NTC or PTC probes for your specific application.\u003c\/p\u003e\n\n\n\u003c\/blockquote\u003e\n\u003ch3\u003e📊 Technical Specifications (Summary)\u003c\/h3\u003e\n\u003ctable\u003e\n\n\u003cthead\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eBrand \/ Series\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd\u003eOsaka F 100\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd\u003eRefrigeration and Industrial Processes\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eMeasuring Range\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd\u003e-50 to 109°C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eRelay Output\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1 Output, 16A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eProbe Input\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1 (NTC or PTC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003ePower Supply (Options)\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd\u003e100-240V AC or 12-24V AC\/DC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eBuzzer\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd\u003eInternal (Alarm and Programming)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eProtection\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd\u003eCompressor Start-up Delay\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\u003ch3\u003e❓ Frequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003ch4\u003e1. What is the practical difference between ON\/OFF regulation and other types (PID)?\u003c\/h4\u003e\n\u003cp\u003eThe \u003cb\u003eON\/OFF\u003c\/b\u003e regulation of the F 100 is ideal for refrigeration applications and processes that tolerate small temperature fluctuations. It is simple, robust, and fast. PID controls are used for processes that require absolutely constant temperature stability without overshoots, although ON\/OFF regulation is sufficient for the majority of cold rooms.\u003c\/p\u003e\n\u003ch4\u003e2. Does the F 100 thermostat include the temperature probe?\u003c\/h4\u003e\n\u003cp\u003eYes. F 100 models are supplied with an \u003cb\u003eNTC probe included\u003c\/b\u003e in the package, regardless of the power option chosen (100-240V or 12-24V). This simplifies installation and ensures immediate compatibility.\u003c\/p\u003e\n\u003ch4\u003e3. Does the 12 to 24V (AC\/DC) power option refer to alternating or direct current?\u003c\/h4\u003e\n\u003cp\u003eThe low-voltage model of the F 100 Thermostat is extremely versatile, as it can be powered by \u003cb\u003e12 to 24V in both alternating current (AC) and direct current (DC)\u003c\/b\u003e. This makes it very flexible for systems powered by batteries or low-voltage transformers.\u003c\/p\u003e\n\u003ch4\u003eElectrical connection diagram for the Osaka F 100 thermostat:\u003c\/h4\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/Captura_de_pantalla_2024-10-17_a_las_13.23.00_480x480.png?v=1729164202\" alt=\"Osaka F 100 thermostat electrical connection diagram\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003ch4 style=\"text-align: start;\"\u003eDimensions of the Osaka F 100 digital thermostat:\u003c\/h4\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/Captura_de_pantalla_2024-10-17_a_las_13.25.08_240x240.png?v=1729164331\" alt=\"Osaka F 100 thermostat dimensions\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","brand":"osaka","offers":[{"title":"100 to 240V","offer_id":50137577292120,"sku":"SE-CF31653","price":81.42,"currency_code":"EUR","in_stock":true},{"title":"12 to 24V","offer_id":50137577259352,"sku":"SE-CF31654","price":90.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/TERMOSTATO-DIGITAL-OSAKA-F100-SONDAINCLUIDA-00.webp?v=1729165923","url":"https:\/\/q-tech.es\/en-en\/products\/termostato-digital-f-100-osaka-para-refrigeracion-y-procesos-industriales","provider":"Q-Tech ® ","version":"1.0","type":"link"}