{"product_id":"stratos-de-wilo","title":"WILO STRATOS","description":"\u003cp\u003e\u003cem\u003e* Models with PN10 threaded connection. Other models, please consult.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecial features\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eEnergy savings due to superior system efficiency with Q-Limit function (flow limitation)\u003c\/li\u003e\n\n\u003cli\u003eImproved Energy Efficiency Index (EEI) ≤0.20 for all single pumps\u003c\/li\u003e\n\n\u003cli\u003eOptimized display for better readability and operation\u003c\/li\u003e\n\n\u003cli\u003eInstallation in confined spaces thanks to compact design and freely positionable liquid crystal display\u003c\/li\u003e\n\n\u003cli\u003eModular concept for linking to all conventional bus systems (e.g., Modbus, BACnet, CAN, LON, PLR)\u003c\/li\u003e\n\n\u003cli\u003eGuaranteed quality and reliability\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003eType\u003c\/h3\u003e\n\u003cp\u003eGlandless circulator pump with threaded or flanged connection, EC motor with automatic power adjustment\u003c\/p\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eAll hot water heating systems, air conditioning installations, closed cooling circuits, and industrial circulation systems.\u003c\/p\u003e\n\u003ch3\u003eFunction\u003c\/h3\u003e\n\u003ch4\u003eManual functions\u003c\/h4\u003e\n\u003cul\u003e\n\n\u003cli\u003eOperating mode setting\u003c\/li\u003e\n\n\u003cli\u003eDifferential pressure setpoint adjustment\u003c\/li\u003e\n\n\u003cli\u003eAutomatic setback mode adjustment\u003c\/li\u003e\n\n\u003cli\u003ePump ON\/OFF adjustment\u003c\/li\u003e\n\n\u003cli\u003eSpeed adjustment (manual mode)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4\u003eAutomatic functions\u003c\/h4\u003e\n\u003cul\u003e\n\n\u003cli\u003eContinuous power adjustment depending on the operating mode\u003c\/li\u003e\n\n\u003cli\u003eAutomatic setback mode\u003c\/li\u003e\n\n\u003cli\u003eUnblocking function\u003c\/li\u003e\n\n\u003cli\u003eSoft start\u003c\/li\u003e\n\n\u003cli\u003eIntegrated full motor protection with trip electronics\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4\u003eExternal control functions\u003c\/h4\u003e\n\u003cul\u003e\n\n\u003cli\u003e\"Priority OFF\" control input (possible with IF Stratos modules)\u003c\/li\u003e\n\n\u003cli\u003e\"Priority min.\" control input (possible with IF Stratos modules)\u003c\/li\u003e\n\n\u003cli\u003e\"Analog 0-10 V\" control input (remote speed control) (possible with IF Stratos modules)\u003c\/li\u003e\n\n\u003cli\u003e\"Analog 0-10 V\" control input (remote setpoint adjustment) (requires IF Stratos modules)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4\u003eIndication and warning functions\u003c\/h4\u003e\n\u003cul\u003e\n\n\u003cli\u003eGeneral fault signal (potential-free NC contact)\u003c\/li\u003e\n\n\u003cli\u003eIndividual operation signal (potential-free NO contact) (requires IF Stratos modules)\u003c\/li\u003e\n\n\u003cli\u003eFault signal lamp\u003c\/li\u003e\n\n\u003cli\u003eLCD display for pump data and error codes\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4\u003eData exchange\u003c\/h4\u003e\n\u003cul\u003e\n\n\u003cli\u003eInfrared interface for wireless data exchange with IR-Stick\/IR-Monitor\u003c\/li\u003e\n\n\u003cli\u003eModbus RTU digital serial interface for connection to Building Automation (BA) via an RS485 BUS system (possible with IF Stratos modules).\u003c\/li\u003e\n\n\u003cli\u003eBACnet MS\/TP slave digital serial interface for connection to Building Automation (BA) via an RS485 BUS system (possible with IF Stratos modules).\u003c\/li\u003e\n\n\u003cli\u003eCAN Modbus digital serial interface for connection to Building Automation (BA) via a CAN BUS system (possible with IF Stratos modules).\u003c\/li\u003e\n\n\u003cli\u003eLON digital serial interface for connection to a LONWorks network (possible with IF Stratos modules)\u003c\/li\u003e\n\n\u003cli\u003ePLR digital serial interface for connection to Building Automation (BA) via Wilo interface converters or company-specific coupling modules (possible with IF Stratos modules)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4\u003eDual pump management (twin pump or 2 single pumps)\u003c\/h4\u003e\n\u003cul\u003e\n\n\u003cli\u003eMain\/standby operation (automatic fault-actuated switchover\/time-dependent pump cycling): various combinations possible with IF Stratos modules (accessories)\u003c\/li\u003e\n\n\u003cli\u003eParallel operation (efficiency-optimized peak-load activation and deactivation): various combinations possible with IF Stratos modules (accessories)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003eScope of delivery\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003ePump\u003c\/li\u003e\n\n\u003cli\u003eIncl. thermal insulation\u003c\/li\u003e\n\n\u003cli\u003eIncl. seals for threaded connection\u003c\/li\u003e\n\n\u003cli\u003eIncl. washers for flange bolts (for nominal connection diameters DN 32 - DN 65)\u003c\/li\u003e\n\n\u003cli\u003eIncl. installation and operating manual\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003ePermissible temperature range from -10 °C to +110 °C\u003c\/li\u003e\n\n\u003cli\u003eMains connection 1~230 V, 50\/60 Hz\u003c\/li\u003e\n\n\u003cli\u003eProtection class IP X4D\u003c\/li\u003e\n\n\u003cli\u003eThreaded or flanged connection (depending on type) Rp 1 to DN 100\u003c\/li\u003e\n\n\u003cli\u003eMax. operating pressure of the standard version: 6\/10 bar and 6 bar (special version: 10 bar or 16 bar)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003eMaterials\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003ePump housing: Cast iron with cataphoretic coating\u003c\/li\u003e\n\n\u003cli\u003eThermal insulation: Polypropylene\u003c\/li\u003e\n\n\u003cli\u003eShaft: Stainless steel\u003c\/li\u003e\n\n\u003cli\u003eBearing: Carbon, metal-impregnated\u003c\/li\u003e\n\n\u003cli\u003eImpeller: Plastic\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eGlandless circulator pump with EC motor and integrated automatic power adjustment\u003c\/li\u003e\n\n\u003cli\u003eRed Button technology and graphic display\u003c\/li\u003e\n\n\u003cli\u003eMotor protection with trip electronics\u003c\/li\u003e\n\n\u003cli\u003ePlug connection for function expansion with optional IF modules for Building Automation (BA)\u003c\/li\u003e\n\n\u003cli\u003eImpeller with 3D-angled blades and carbon-fiber-reinforced composite shroud\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cms.media.wilo.com\/dcidocpfinder\/wilo_f_0200002900018e2300010092\/1181566\/wilo_f_0200002900018e2300010092.pdf\" target=\"_blank\" title=\"Descargar manual técnico bomba circuladora wilo stratos\" rel=\"noopener noreferrer\"\u003eDownload Wilo Stratos technical manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Wilo","offers":[{"title":"Stratos 30\/1-6 180mm Ref. 2090449","offer_id":19637693448280,"sku":"SE-AC51255\/BA-91153","price":706.82,"currency_code":"EUR","in_stock":true},{"title":"Stratos 30\/1-8 180mm Ref. 2090450","offer_id":19637696725080,"sku":"SE-AC51256\/BA-88231","price":824.82,"currency_code":"EUR","in_stock":false},{"title":"Stratos 30\/1-10 180mm Ref. 2103616","offer_id":19637697347672,"sku":"SE-AC51257\/BA-90260","price":1019.52,"currency_code":"EUR","in_stock":false},{"title":"Stratos 30\/1-12 180mm Ref. 2090451","offer_id":19637697609816,"sku":"SE-AC51258\/BA-61334","price":1175.28,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/wilo-stratos-de-wilo-stratos-30-1-6-180mm-ref-2090449-52965540757848.jpg?v=1702916060","url":"https:\/\/q-tech.es\/en-en\/products\/stratos-de-wilo","provider":"Q-Tech ® ","version":"1.0","type":"link"}