{"product_id":"recambio-celula-hayward-turbocell-aquarite-original","title":"TurboCell cell for Aquarite","description":"\u003ch3 data-path-to-node=\"6\"\u003eHayward TurboCell: High-Performance Salt Electrolysis Engineering\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-path-to-node=\"7\" data-index-in-node=\"3\"\u003eHayward TurboCell\u003c\/b\u003e is the original replacement cell designed for AquaRite salt chlorination systems. This engineered component uses titanium plates coated with precious metals to transform salt into free chlorine efficiently and consistently. The cost of inaction when using low-quality compatible cells includes erratic disinfection and potential damage to the controller's electronic board. The \u003cb data-path-to-node=\"7\" data-index-in-node=\"433\"\u003eHayward TurboCell\u003c\/b\u003e resolves these operational risks by guaranteeing precise chlorine production and superior service life under intensive working conditions.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eTitanium Plate Technology and Disinfection Efficiency\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-path-to-node=\"9\" data-index-in-node=\"3\"\u003eHayward TurboCell\u003c\/b\u003e uses an oversized plate configuration that optimizes water hydrolysis. This technology allows for the maintenance of hospital-grade sanitation levels with a reduced salt concentration, protecting both user health and material integrity.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eNSF Certification:\u003c\/b\u003e The only original replacement that meets \u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"76\"\u003eNSF\u003c\/b\u003e performance and safety standards for commercial and residential pools.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eChemical Savings:\u003c\/b\u003e Reduces dependence on liquid or granular chlorine by generating pure disinfectant directly in the installation's return flow.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eSelf-Cleaning by Polarity Reversal:\u003c\/b\u003e The AquaRite system manages automatic cleaning cycles in the cell to eliminate lime scale without manual intervention.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eIntelligent Monitoring:\u003c\/b\u003e Integrates sensors that communicate critical data regarding water temperature and salinity levels to the central system in real time.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eChemical Robustness and Critical Installation Standards\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003eThe architecture of the \u003cb data-path-to-node=\"12\" data-index-in-node=\"22\"\u003eHayward TurboCell\u003c\/b\u003e is engineered for continuous operation in aggressive chemical environments. Its design facilitates rapid replacement in the technical room, minimizing downtime in critical installations such as hotels, sports clubs, or high-end residences.\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eHigh-Strength Transparent Housing:\u003c\/b\u003e Manufactured with technical polymers that allow for visual inspection of the plates without disassembling the equipment.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003ePlug and Play Connectivity:\u003c\/b\u003e Includes a reinforced \u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"70\"\u003e4.5-meter\u003c\/b\u003e connection cable with a watertight connector for interference-free data transmission.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eCorrosion Resistance:\u003c\/b\u003e The titanium plates are treated to withstand galvanic oxidation and wear from hydraulic friction.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eProduction Versatility:\u003c\/b\u003e Available in versions based on pool volume, ensuring proportional dosing tailored to actual demand.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"14\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eAvailable Models:\u003c\/b\u003e T-CELL-3 (up to 60 m3), T-CELL-9 (up to 95 m3), T-CELL-15 (up to 150 m3).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eElectrode Material:\u003c\/b\u003e Titanium with ruthenium and iridium coating.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eEstimated Service Life:\u003c\/b\u003e Up to \u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"26\"\u003e10,000 hours\u003c\/b\u003e of operation.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eCable Length:\u003c\/b\u003e \u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"20\"\u003e4.5 meters\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,4,0\"\u003e\u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure:\u003c\/b\u003e \u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"27\"\u003e2 bar\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,5,0\"\u003e\u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"0\"\u003eHydraulic Connections:\u003c\/b\u003e \u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"44\"\u003e2-inch\u003c\/b\u003e union fittings.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,6,0\"\u003e\u003cb data-path-to-node=\"15,6,0\" data-index-in-node=\"0\"\u003eCertifications:\u003c\/b\u003e \u003cb data-path-to-node=\"15,6,0\" data-index-in-node=\"17\"\u003eNSF 50\u003c\/b\u003e and CE marking.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,7,0\"\u003e\u003cb data-path-to-node=\"15,7,0\" data-index-in-node=\"0\"\u003eRecommended Salinity:\u003c\/b\u003e \u003cb data-path-to-node=\"15,7,0\" data-index-in-node=\"23\"\u003e2,700 ppm\u003c\/b\u003e to \u003cb data-path-to-node=\"15,7,0\" data-index-in-node=\"34\"\u003e3,400 ppm\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eCompatibility and Application Limits\u003c\/h3\u003e\n\u003cp data-path-to-node=\"17\"\u003eThe \u003cb data-path-to-node=\"17\" data-index-in-node=\"3\"\u003eHayward TurboCell\u003c\/b\u003e is compatible with all \u003cstrong\u003eAquaRite\u003c\/strong\u003e, \u003cstrong\u003eAquaRite Pro\u003c\/strong\u003e, and \u003cstrong\u003eSwimPure Plus\u003c\/strong\u003e systems. For optimal performance, it must be installed in the last section of the return pipe, after the filter and the heating system.\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cb data-path-to-node=\"17\" data-index-in-node=\"236\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e It should not operate with salt levels below \u003cb data-path-to-node=\"17\" data-index-in-node=\"304\"\u003e2,500 ppm\u003c\/b\u003e or above \u003cb data-path-to-node=\"17\" data-index-in-node=\"328\"\u003e4,500 ppm\u003c\/b\u003e, as this may reduce the service life of the electrodes. Do not clean the plates with metal tools; use only diluted acid solutions according to the technical manual.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"18\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"0\"\u003eWhy should I buy the original Hayward TurboCell instead of a compatible one?\u003c\/b\u003e Only the \u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"88\"\u003eHayward TurboCell\u003c\/b\u003e guarantees proper communication with your AquaRite system's microprocessor. Compatible cells often provide erroneous salt readings and have up to \u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"286\"\u003e50%\u003c\/b\u003e less durability due to the low quality of the plate coating.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"0\"\u003eHow do I know when it is time to replace my TurboCell?\u003c\/b\u003e Your system will display a \"Check Cell\" or \"Inspect Cell\" warning. If, after an acid cleaning, the chlorine production level does not recover or the system indicates \"Low Salt\" despite having sufficient salt, the cell's electrodes have reached the end of their operational life.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"0\"\u003eCan I install a T-CELL-15 in a small pool so it lasts longer?\u003c\/b\u003e Yes. This is a recommended engineering practice. By using a higher-capacity \u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"131\"\u003eHayward TurboCell\u003c\/b\u003e, the system runs for fewer hours to produce the same amount of chlorine, significantly extending the component's service life in years.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"20\"\u003eQ-Tech Engineering Support\u003c\/h3\u003e\n\u003cp data-path-to-node=\"21\"\u003eAt Q-tech.es, we provide specialized technical assistance for the configuration of IT\/OT water treatment systems. If you require support for diagnosing your chlorinator or on-site assistance for replacing your \u003cb data-path-to-node=\"21\" data-index-in-node=\"225\"\u003eHayward TurboCell\u003c\/b\u003e, contact our team of field engineers.\u003c\/p\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: 24px; top: 169.062px;\"\u003e\n\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"Hayward","offers":[{"title":"T-Cell-3-E cell","offer_id":56933958648152,"sku":"SCP-HAY-450-1209","price":659.62,"currency_code":"EUR","in_stock":true},{"title":"T-Cell-9-E cell","offer_id":56933958680920,"sku":"SCP-450-1210","price":820.1,"currency_code":"EUR","in_stock":true},{"title":"T-Cell-15-E Cell","offer_id":56933958713688,"sku":"SCP-HAY-450-1208","price":1040.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/CELULA-TURBOCELL-CLORADOR-AQUARITE-HAYWARD-00.webp?v=1773921712","url":"https:\/\/q-tech.es\/en-en\/products\/recambio-celula-hayward-turbocell-aquarite-original","provider":"Q-Tech ® ","version":"1.0","type":"link"}