{"product_id":"kit-solar-termico-vmc322-esbe-31521100","title":"ESBE VMC322 Series solar kit 31521100","description":"\u003cp\u003eThe \u003cb\u003eESBE VMC322 Series Solar Thermal Kit\u003c\/b\u003e is a dual-function unit essential for optimizing efficiency and safety in \u003cb\u003eDomestic Hot Water (DHW)\u003c\/b\u003e systems that integrate solar energy.\u003c\/p\u003e\n\u003cp\u003eDesigned by ESBE, this kit not only guarantees maximum utilization of the heat captured by the solar collector but also offers a crucial \u003cb\u003eanti-scald safety function\u003c\/b\u003e for the end user. It is the ideal solution for small-scale DHW installations that require precise and reliable temperature control.\u003c\/p\u003e\n\u003ch3\u003e✨ Dual Functionality and Operational Benefits (E-E-A-T)\u003c\/h3\u003e\n\u003cp\u003eThe VMC322 is an advanced engineering component that intelligently manages the flow of domestic hot water.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eTemperature Control and Intelligent Diversion\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cb\u003eMaximum Solar Utilization:\u003c\/b\u003e If the water from the solar collector is at an optimal temperature, it is directed straight to be mixed as DHW.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cb\u003eGuaranteed Thermal Support:\u003c\/b\u003e If the solar water temperature is insufficient, the kit automatically diverts it to an additional heat source (such as a gas boiler) to ensure the service temperature.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cb\u003ePrecise DHW Mixing:\u003c\/b\u003e It acts as a thermostatic mixing valve to ensure the outlet water reaches the selected setpoint temperature (\u003cspan class=\"math-inline\" data-math=\"45 \\, {^\\circ}\\text{C}\"\u003e45ºC\u003c\/span\u003e, \u003cspan class=\"math-inline\" data-math=\"50 \\, {^\\circ}\\text{C}\"\u003e50ºC\u003c\/span\u003e, or \u003cspan class=\"math-inline\" data-math=\"60 \\, {^\\circ}\\text{C}\"\u003e60ºC\u003c\/span\u003e).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cb\u003eIdeal for Compact Applications:\u003c\/b\u003e Designed specifically for small-scale solar systems with optimal performance of \u003cspan class=\"math-inline\" data-math=\"Kvs = 1,5\"\u003eKvs = 1.5\u003c\/span\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cb\u003eAnti-Scald Safety (Key Trust Feature)\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cb\u003eAutomatic Cold Water Failure Cut-off:\u003c\/b\u003e In the unlikely event of a cold water supply failure, the hot water supply is shut off immediately.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cb\u003eAbsolute Prevention:\u003c\/b\u003e This safety feature prevents scalding from excessively hot water, increasing reliability and complying with safety regulations for DHW installations.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003e⚙️ Detailed Technical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003eESBE VMC322\u003c\/b\u003e is designed to operate with maximum efficiency and precision:\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cb\u003eMain Applications:\u003c\/b\u003e Solar heating systems and potable water circuits (DHW).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cb\u003eMaximum Collector Flow Rate:\u003c\/b\u003e \u003cspan class=\"math-inline\" data-math=\"0,7 \\, \\text{L\/s}\"\u003e0.7 L\/s\u003c\/span\u003e (\u003cspan class=\"math-inline\" data-math=\"42 \\, \\text{L\/min}\"\u003e42 L\/min\u003c\/span\u003e).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cb\u003eMaximum Collector Temperature:\u003c\/b\u003e \u003cspan class=\"math-inline\" data-math=\"95 \\, {^\\circ}\\text{C}\"\u003e95ºC\u003c\/span\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cb\u003eSpecific Performance:\u003c\/b\u003e \u003cspan class=\"math-inline\" data-math=\"Kvs = 1,5\"\u003eKvs = 1.5\u003c\/span\u003e (for small-scale systems).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cb\u003eConnections:\u003c\/b\u003e \u003cspan class=\"math-inline\" data-math='1 \\text{\"}'\u003e1\"\u003c\/span\u003e external thread (available in various models).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cb\u003eRegulation:\u003c\/b\u003e Determined by the control electronics of the heat pump or main regulation system.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003eAvailable Models of the VMC322 Series\u003c\/h3\u003e\n\u003cp\u003eThe choice of model depends on the comfort temperature required by the installation:\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cb\u003eVMC322 (\u003cspan class=\"math-inline\" data-math='1\\text{\"}'\u003e1\"\u003c\/span\u003e):\u003c\/b\u003e Fixed outlet temperature of \u003cspan class=\"math-inline\" data-math=\"45 \\, {^\\circ}\\text{C}\"\u003e45ºC\u003c\/span\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cb\u003eVMC322 (\u003cspan class=\"math-inline\" data-math='1\\text{\"}'\u003e1\"\u003c\/span\u003e):\u003c\/b\u003e Fixed outlet temperature of \u003cspan class=\"math-inline\" data-math=\"50 \\, {^\\circ}\\text{C}\"\u003e50ºC\u003c\/span\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cb\u003eVMC322 (\u003cspan class=\"math-inline\" data-math='1\\text{\"}'\u003e1\"\u003c\/span\u003e):\u003c\/b\u003e Fixed outlet temperature of \u003cspan class=\"math-inline\" data-math=\"60 \\, {^\\circ}\\text{C}\"\u003e60ºC\u003c\/span\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cblockquote\u003e\n\n\u003cp\u003e\u003cb\u003eAre you an installer or an industry professional?\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003eCorrect selection and installation of the VMC300 series (or the VMC500 for larger systems) is crucial. Contact our \u003cb\u003especialized Technical Support Service\u003c\/b\u003e for advice on sizing and connection diagrams. \u003cb\u003eCall us or request technical documentation!\u003c\/b\u003e\u003c\/p\u003e\n\n\n\u003c\/blockquote\u003e\n\u003ch3\u003e❓ Frequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003ch4\u003e1. What is the role of the VMC322 Kit in a heat pump installation?\u003c\/h4\u003e\n\u003cp\u003eThe kit is commonly used in heat pump installations to act as a hot water diverter between the radiator (or heating) circuit and the potable water production circuit (DHW). The heat pump's electronic unit sends the signal that determines when this diversion occurs.\u003c\/p\u003e\n\u003ch4\u003e2. When should I choose the VMC500 Series instead of the VMC322?\u003c\/h4\u003e\n\u003cp\u003eThe VMC322 is designed for more compact solar heating systems with a \u003cspan class=\"math-inline\" data-math=\"Kvs\"\u003eKvs\u003c\/span\u003e of \u003cspan class=\"math-inline\" data-math=\"1,5\"\u003e1.5\u003c\/span\u003e. If your installation is \u003cb\u003elarger\u003c\/b\u003e and requires a higher flow rate to handle more consumption points or larger collectors, you should consult and purchase the ESBE \u003cb\u003eVMC500 Series\u003c\/b\u003e, designed for higher performance.\u003c\/p\u003e\n\u003ch4\u003e3. How does the anti-scald safety function work?\u003c\/h4\u003e\n\u003cp\u003eThis is a critical passive safety function. The internal mechanism automatically shuts off the hot water flow to the consumption point if it detects an interruption or insufficient pressure in the cold water line, thereby preventing an uncontrolled increase in outlet temperature.\u003c\/p\u003e","brand":"Esbe","offers":[{"title":"Default Title","offer_id":12317549330520,"sku":"SE-CO10435","price":470.82,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/esbe-kit-solar-serie-vmc322-esbe-31521100-default-title-52965384388952.jpg?v=1702915051","url":"https:\/\/q-tech.es\/en-en\/products\/kit-solar-termico-vmc322-esbe-31521100","provider":"Q-Tech ® ","version":"1.0","type":"link"}