{"product_id":"flow-switch-sugar-valley-detector-flujo-seguridad","title":"Flow switch for Sugar Valley equipment","description":"\u003ch3 data-path-to-node=\"6\"\u003eSugar Valley Flow Switch: Safety Engineering for Electrolysis Systems\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-path-to-node=\"7\" data-index-in-node=\"3\"\u003eSugar Valley Flow Switch\u003c\/b\u003e is a mechanical safety device designed to monitor water movement within the hydraulic circuit. This component automatically stops chlorine generation in the event of low flow, protecting the electrolysis cell against gas buildup. The cost of inaction when operating without a flow detector includes the explosive accumulation of hydrogen gas and irreversible failure due to overheating of the treatment cell. The \u003cb data-path-to-node=\"7\" data-index-in-node=\"484\"\u003eSugar Valley Flow Switch\u003c\/b\u003e resolves these operational risks through real-time physical monitoring that ensures hardware integrity.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003ePreventive Protection and Critical Flow Control\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-path-to-node=\"9\" data-index-in-node=\"3\"\u003eSugar Valley Flow Switch\u003c\/b\u003e stands out for its ability to act immediately on the chlorinator’s electronic circuit. Its mechanical architecture ensures a reliable response to filtration pump failures or air in the piping, optimizing the installation's technical safety.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003ePhysical Detection Mechanism:\u003c\/b\u003e Uses a paddle sensitive to fluid movement to send an interrupt signal to the central control system.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eDedicated Electronic Circuit:\u003c\/b\u003e Includes a processing board that interprets the mechanical signal and blocks power to the cell instantly.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eHigh-Fidelity Connectivity:\u003c\/b\u003e Integrates a special dual connector designed for error-free integration into the motherboard of Sugar Valley equipment.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eIT\/OT Risk Prevention:\u003c\/b\u003e Acts as a physical firewall that prevents the system from operating under out-of-range hydraulic conditions.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMechanical Robustness and Industrial Safety Standards\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003eThe manufacturing of the \u003cb data-path-to-node=\"12\" data-index-in-node=\"19\"\u003eSugar Valley Flow Switch\u003c\/b\u003e follows safety protocols for high-level hydraulic instrumentation. Its design allows for seamless integration into existing manifolds, ensuring operational continuity in demanding water treatment environments.\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eHigh-Resistance Components:\u003c\/b\u003e Manufactured with technical materials that withstand continuous exposure to chemical products and pressure fluctuations.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eSimplified Installation:\u003c\/b\u003e The kit includes all elements necessary for a quick safety upgrade on compatible equipment.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eMinimum Flow Detection:\u003c\/b\u003e Calibrated to detect critical flow velocities that compromise the cooling of the titanium electrodes.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eSystem Sustainability:\u003c\/b\u003e By preventing dry running, the detector contributes to cell longevity and reduces the need for emergency repairs.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eSensor Type:\u003c\/b\u003e Mechanical paddle flow detector.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eCompatibility:\u003c\/b\u003e Sugar Valley electrolysis systems (Hidrolife, Oxilife, Bionet, Aquascenic).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eElectrical Connection:\u003c\/b\u003e Special dual connector included.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eComponents:\u003c\/b\u003e 1 electronic processing circuit + 1 mechanical sensor.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,4,0\"\u003e\u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"0\"\u003eFunction:\u003c\/b\u003e Safety cutoff due to lack of flow.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,5,0\"\u003e\u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"0\"\u003eBody Material:\u003c\/b\u003e High-density technical polymer.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eCompatibility and Application Limits\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"17\"\u003eThe \u003cb data-path-to-node=\"17\" data-index-in-node=\"3\"\u003eSugar Valley Flow Switch\u003c\/b\u003e is compatible with all controllers in the Sugar Valley range and its licensed brands. It must be installed in the pipe section containing the electrolysis cell, respecting the flow direction indicated by the arrow on the sensor body.\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cb data-path-to-node=\"17\" data-index-in-node=\"278\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not install in pipe sections with extreme turbulence or in excessive proximity to 90-degree elbows. The sensor must be kept free of limescale deposits to ensure the internal paddle moves freely and to avoid false flow positives.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"0\"\u003eWhy is it mandatory to install the Sugar Valley Flow Switch?\u003c\/b\u003e Electrolysis naturally generates gases. Without water flow, these gases accumulate in the cell and can cause physical rupture of the vessel or a fire due to overheating. The \u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"253\"\u003eSugar Valley Flow Switch\u003c\/b\u003e is the only device that guarantees the equipment only produces chlorine when there is actual circulation.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"0\"\u003eWhat exactly does this safety kit include?\u003c\/b\u003e The kit supplied by Q-Tech includes the mechanical detector that is inserted into the pipe and the electronic circuit necessary for the main Sugar Valley equipment board to recognize the flow signal. It is a complete engineering solution for protecting your system.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"0\"\u003eDoes this flow detector require maintenance?\u003c\/b\u003e A visual inspection is recommended at the start of each season. You should verify that the mechanical paddle moves freely and that there is no accumulated dirt. Simple maintenance ensures that the protection system responds with industrial precision to any anomaly.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"20\"\u003e\u003cb data-path-to-node=\"20\" data-index-in-node=\"0\"\u003eQ-Tech Engineering Support\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"21\"\u003eAt Q-tech.es, we provide specialized technical assistance for configuring safety protocols in Sugar Valley systems. If you require installation support or on-site technical assistance for your \u003cb data-path-to-node=\"21\" data-index-in-node=\"216\"\u003eSugar Valley Flow Switch\u003c\/b\u003e, contact our field engineers by phone or in person.\u003c\/p\u003e","brand":"Sugar Valley","offers":[{"title":"Default Title","offer_id":34621782524057,"sku":"PS-11343","price":109.74,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/sugar-valley-detector-de-flujo-para-equipos-sugar-valley-flow-switch-default-title-52965602132312.jpg?v=1702916509","url":"https:\/\/q-tech.es\/en-en\/products\/flow-switch-sugar-valley-detector-flujo-seguridad","provider":"Q-Tech ® ","version":"1.0","type":"link"}