{"product_id":"electrodo-original-astralpool-basic-sel-clear-7-placas","title":"AstralPool Sel Clear 7-plate Basic Electrode","description":"\u003ch3 data-path-to-node=\"6\"\u003eAstralPool Basic Sel Clear 7-Plate: Original Salt Electrolysis Engineering\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"7\"\u003eAstralPool Basic Sel Clear 7-plate electrode\u003c\/b\u003e is the original disinfection component designed for Basic Sel and Sel Clear salt chlorination systems. This electrode uses high-purity titanium plates to transform sodium chloride into active chlorine consistently and efficiently. The cost of inaction when using compatible electrodes results in poor disinfection and potential failures in the unit's power board. The \u003cb data-index-in-node=\"444\" data-path-to-node=\"7\"\u003eAstralPool Basic Sel Clear\u003c\/b\u003e ensures stable chlorine production, protecting the health of users and the service life of the electronic controller.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eOperational Efficiency and Polarity Reversal Self-Cleaning\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe 7-plate \u003cb data-index-in-node=\"3\" data-path-to-node=\"9\"\u003eAstralPool Basic Sel Clear\u003c\/b\u003e optimizes the electrolysis process through a contact surface area calculated for systems up to \u003cb data-index-in-node=\"147\" data-path-to-node=\"9\"\u003e55 m3\u003c\/b\u003e. The original design ensures that electrical resistance remains within the manufacturer's nominal parameters.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eReinforced Titanium Plates:\u003c\/b\u003e The precious metal coating maximizes electron transfer and reduces premature electrode wear.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eSelf-Cleaning Technology:\u003c\/b\u003e The plate architecture is compatible with polarity reversal cycles, automatically eliminating limescale deposits.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eConstant Chlorine Production:\u003c\/b\u003e Generates up to \u003cb data-index-in-node=\"44\" data-path-to-node=\"10,2,0\"\u003e13 g\/h\u003c\/b\u003e of free chlorine, ensuring crystal-clear water even under high organic load conditions.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003ePrecision Installation:\u003c\/b\u003e The body design and connection terminals ensure a watertight fit that prevents hydraulic leaks and electrical corrosion.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cmeta charset=\"utf-8\"\u003e\n\n\u003cp\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eOriginal AstralPool electrode replacement for salt chlorinators of the \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eAstral Sel Basic, Sel Clear, and Energy Sel\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e series.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cstrong\u003eAvailable in 3 models\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"padding-left: 30px;\"\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eFor Astral Sel Basic \/ Sel Clear \/ Energy Sel 30: 54051 (former ref. 4408060203)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eFor Astral Sel Basic \/ Sel Clear \/ Energy Sel 55: 54052 (former ref. 4408060204)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eFor Astral Sel Basic \/ Sel Clear \/ Energy Sel 95: 54053 (former ref. 4408060205)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eMechanical Robustness and Industrial Safety Standards\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003eThe manufacturing of the \u003cb data-index-in-node=\"19\" data-path-to-node=\"12\"\u003eBasic Sel Clear Electrode\u003c\/b\u003e follows Fluidra's quality protocols. Its structure facilitates quick replacement in the technical room, reducing downtime in residential and commercial installations.\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,0,0\"\u003eChemically Resistant Body:\u003c\/b\u003e The support materials withstand direct injection of pH correctors and elevated water flow temperatures.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,1,0\"\u003eProtected Connection Terminals:\u003c\/b\u003e The design prevents overheating at contact points, protecting the control equipment wiring.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,2,0\"\u003eFactory Certification:\u003c\/b\u003e Each unit is verified to meet the chlorine production curve specified for the Basic range models.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,3,0\"\u003eSystem Sustainability:\u003c\/b\u003e By maintaining optimal conductivity, the system consumes less energy to generate the necessary oxidation potential.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eCompatibility and Application Limits\u003c\/h3\u003e\n\u003cp data-path-to-node=\"17\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"17\"\u003eBasic Sel Clear 7-plate electrode\u003c\/b\u003e is compatible exclusively with AstralPool Basic series salt chlorinators designed for 7 plates. It must be installed after the filter and before any additional heating or chemical dosing systems.\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cb data-index-in-node=\"257\" data-path-to-node=\"17\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not clean the plates with metal objects or concentrated acid solutions (maximum 10%). Do not operate with salinity below \u003cb data-index-in-node=\"409\" data-path-to-node=\"17\"\u003e3 g\/L\u003c\/b\u003e, as this causes accelerated wear of the titanium coating and voiding of the warranty.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"18\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"19,0,0\"\u003eWhy should I choose the original AstralPool electrode?\u003c\/b\u003e The original \u003cb data-index-in-node=\"80\" data-path-to-node=\"19,0,0\"\u003eAstralPool Basic Sel Clear\u003c\/b\u003e electrode ensures correct communication with the electronic board. Compatible models often cause erroneous salt readings and have up to 50% shorter service life due to low titanium quality.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"19,1,0\"\u003eWhen is it necessary to change my chlorinator's electrode?\u003c\/b\u003e You should replace it when chlorine production is insufficient despite having correct salt levels (approx. \u003cb data-index-in-node=\"176\" data-path-to-node=\"19,1,0\"\u003e4 g\/L\u003c\/b\u003e). If the plates show visible wear or the equipment indicates a lack of production after cleaning, the electrode has exhausted its chemical capacity.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"19,2,0\"\u003eHow can I extend the life of my 7-plate cell?\u003c\/b\u003e Maintain the water pH between \u003cb data-index-in-node=\"84\" data-path-to-node=\"19,2,0\"\u003e7.2\u003c\/b\u003e and \u003cb data-index-in-node=\"90\" data-path-to-node=\"19,2,0\"\u003e7.4\u003c\/b\u003e. Uncontrolled pH forces the cell to work more hours to keep the water disinfected, which accelerates wear on the noble metal coating of the \u003cb data-index-in-node=\"272\" data-path-to-node=\"19,2,0\"\u003eBasic Sel Clear\u003c\/b\u003e plates.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"20\"\u003eQ-Tech Engineering Support\u003c\/h3\u003e\n\u003cp data-path-to-node=\"21\"\u003eAt Q-tech.es, we provide specialized technical assistance for optimizing water treatment systems. If you need to validate the compatibility of the \u003cb data-index-in-node=\"160\" data-path-to-node=\"21\"\u003eAstralPool Basic Sel Clear\u003c\/b\u003e or require on-site support for commissioning, please contact our field engineers.\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"AstralPool","offers":[{"title":"For Astral Sel Clear 30","offer_id":42546364874978,"sku":"AS-54051","price":729.24,"currency_code":"EUR","in_stock":true},{"title":"For Astral Sel Clear 55","offer_id":42546364907746,"sku":"AS54052","price":1058.46,"currency_code":"EUR","in_stock":true},{"title":"For Astral Sel Clear 95","offer_id":42546364940514,"sku":"AS-54053","price":1410.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/astralpool-electrodo-basic-sel-clear-7-placas-astralpool-para-astral-sel-clear-30-52965636505944.jpg?v=1702916722","url":"https:\/\/q-tech.es\/en-en\/products\/electrodo-original-astralpool-basic-sel-clear-7-placas","provider":"Q-Tech ® ","version":"1.0","type":"link"}