{"product_id":"electrodo-original-astral-sel-9-placas-astralpool","title":"Astral Sel 9-plate electrode AstralPool","description":"\u003ch3 data-path-to-node=\"6\"\u003eAstral Sel 9-Plate: High-Durability Electrolysis Engineering\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"7\"\u003eAstral Sel 9-plate electrode\u003c\/b\u003e is the original disinfection component for AstralPool salt chlorination systems. This device uses titanium plates coated with noble metals to transform sodium chloride into a high-purity active disinfectant. The cost of inaction when using compatible electrodes results in poor disinfection and a risk of short circuits in the control equipment. The \u003cb data-index-in-node=\"426\" data-path-to-node=\"7\"\u003eAstral Sel Cell\u003c\/b\u003e ensures stable chlorine production, protecting the health of users and the technical integrity of the installation.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eDisinfection Efficiency via Reinforced Titanium Plates\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-index-in-node=\"10\" data-path-to-node=\"9\"\u003eAstral Sel 9-plate\u003c\/b\u003e cell is designed to maximize electrical contact surface within the water flow. This engineering configuration allows for efficient hydrolysis even under conditions of high chemical demand.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eLong-Lasting Coating:\u003c\/b\u003e The plates feature a special treatment that extends effective operating hours in aggressive saline environments.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eHomogeneous Production:\u003c\/b\u003e The 9-plate design ensures a constant release of free chlorine, avoiding oxidation spikes that damage the pool liner.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eOperational Sustainability:\u003c\/b\u003e Optimizes the salt chlorinator's electrical consumption by requiring less intensity to generate the necessary oxidation potential.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003ePrecision Installation:\u003c\/b\u003e The connection terminal is designed for a perfect fit, preventing terminal overheating caused by loose contacts.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eMechanical Robustness and Safety Standards\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003eThe construction of the \u003cb data-index-in-node=\"20\" data-path-to-node=\"12\"\u003eAstral Sel Electrode\u003c\/b\u003e follows AstralPool's industrial quality standards. Its architecture facilitates rapid replacement in the technical room, reducing downtime in residential and commercial facilities.\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,0,0\"\u003eChemically Resistant Body:\u003c\/b\u003e The support materials are prepared to withstand the injection of pH correctors and high temperatures in the return flow.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,1,0\"\u003eProtected Terminals:\u003c\/b\u003e Electrical connection points feature protection to prevent corrosion from ambient humidity inside the cell.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,2,0\"\u003ePolarity Reversal Architecture:\u003c\/b\u003e Designed specifically to work with the self-cleaning cycles of Astral Sel equipment, minimizing scale buildup.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,3,0\"\u003eFactory Certification:\u003c\/b\u003e Each electrode undergoes conductivity tests to ensure it meets the specified grams of production per hour.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cmeta charset=\"utf-8\"\u003e\n\n\u003cp\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eAvailable in 4 models:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"padding-left: 30px;\"\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eFor Sel Astral 40: 28419 (former ref. 4408060124)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eFor Astral Sel 60 \/ Sel Pure 60: 54054 (former ref. 4408060125)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eFor Astral Sel 100 \/ Sel Pure 100: 54055 (former ref. 4408060126)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003eFor Astral Sel 160 \/ Sel Pure 160: 54056 (former ref. 4408060127)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"14\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,0,0\"\u003eNumber of Plates:\u003c\/b\u003e 9 titanium plates.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,1,0\"\u003eBrand:\u003c\/b\u003e AstralPool (Original).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,2,0\"\u003eCompatibility:\u003c\/b\u003e Fluidra \u003cstrong\u003eAstral Sel and Sel Pure\u003c\/strong\u003e systems.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,3,0\"\u003eCoating Material:\u003c\/b\u003e Precious metal mix (Ruthenium\/Iridium).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,4,0\"\u003eCleaning Type:\u003c\/b\u003e Compatible with electronic polarity reversal.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,5,0\"\u003eEstimated Lifespan:\u003c\/b\u003e Between \u003cb data-index-in-node=\"26\" data-path-to-node=\"15,5,0\"\u003e3000\u003c\/b\u003e and \u003cb data-index-in-node=\"33\" data-path-to-node=\"15,5,0\"\u003e5000 hours\u003c\/b\u003e (depending on water hardness).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15,6,0\"\u003eElectrical Connection:\u003c\/b\u003e Threaded or pressure terminals (depending on manufacturing version).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eCompatibility and Application Limits\u003c\/h3\u003e\n\u003cp data-path-to-node=\"17\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"17\"\u003eAstral Sel 9-plate electrode\u003c\/b\u003e is exclusively compatible with salt chlorinators in the Astral Sel and Sel Pure range that use this plate configuration. It must be installed after the filter and before any heating system.\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cb data-index-in-node=\"230\" data-path-to-node=\"17\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not submerge in high-concentration acidic solutions (greater than 10%) for prolonged periods, as this degrades the plate coating. Do not operate with salinity below \u003cb data-index-in-node=\"441\" data-path-to-node=\"17\"\u003e3000 ppm\u003c\/b\u003e to avoid premature titanium wear.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"18\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"19,0,0\"\u003eWhy choose the original AstralPool electrode instead of a compatible one?\u003c\/b\u003e The original \u003cb data-index-in-node=\"80\" data-path-to-node=\"19,0,0\"\u003eAstral Sel Electrode\u003c\/b\u003e ensures that the chlorinator correctly detects water conductivity. Compatible models often trigger \"low salt\" errors and have up to 50% shorter lifespans due to their low precious metal content.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"19,1,0\"\u003eWhen should I replace my Astral Sel 9-plate cell?\u003c\/b\u003e You should perform the replacement when you observe that chlorine production is null despite having the correct salt levels (approx. \u003cb data-index-in-node=\"185\" data-path-to-node=\"19,1,0\"\u003e4000 ppm\u003c\/b\u003e). If the plates are white or worn out after cleaning, their chemical reaction capacity has been exhausted.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"19,2,0\"\u003eHow can I extend the life of this replacement part?\u003c\/b\u003e Keep the water pH between \u003cb data-index-in-node=\"76\" data-path-to-node=\"19,2,0\"\u003e7.2\u003c\/b\u003e and \u003cb data-index-in-node=\"82\" data-path-to-node=\"19,2,0\"\u003e7.4\u003c\/b\u003e. Uncontrolled pH forces the cell to work more hours than necessary, accelerating the wear of the \u003cb data-index-in-node=\"236\" data-path-to-node=\"19,2,0\"\u003eAstral Sel\u003c\/b\u003e titanium plate coating.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"20\"\u003eQ-Tech Engineering Support\u003c\/h3\u003e\n\u003cp data-path-to-node=\"21\"\u003eAt Q-tech.es, we offer personalized technical assistance for professional installers and private customers. If you need to validate the compatibility of the \u003cb data-index-in-node=\"146\" data-path-to-node=\"21\"\u003eAstral Sel Electrode\u003c\/b\u003e with your equipment or require support during startup, contact our field engineers.\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003cspan style=\"vertical-align: inherit;\" dir=\"auto\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"AstralPool","offers":[{"title":"For Astral Sel 40 - 9 plates","offer_id":33040204562570,"sku":"AS-28419","price":982.94,"currency_code":"EUR","in_stock":true},{"title":"For Astral Sel 60 - 9 plates","offer_id":33040103145610,"sku":"AS-54054","price":1247.26,"currency_code":"EUR","in_stock":true},{"title":"For Astral Sel 100 - 9 plates","offer_id":33040103211146,"sku":"AS-54055","price":1357.0,"currency_code":"EUR","in_stock":true},{"title":"For Astral Sel 160 - 9 plates","offer_id":33040103243914,"sku":"AS-54056","price":1534.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/astralpool-electrodo-astral-sel-9-placas-astralpool-para-astral-sel-40-9-placas-52965582963032.jpg?v=1702916339","url":"https:\/\/q-tech.es\/en-en\/products\/electrodo-original-astral-sel-9-placas-astralpool","provider":"Q-Tech ® ","version":"1.0","type":"link"}