{"product_id":"celula-recambio-zodiac-ei-ei2-gensalt-original","title":"Zodiac Ei, Ei2, and GenSalt Cell","description":"\u003cp data-path-to-node=\"6\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"6\"\u003eZodiac Ei and Ei2 chlorinator cell electrode\u003c\/b\u003e is the critical power component for disinfectant generation via salt electrolysis. This original spare part ensures operational continuity and electrochemical efficiency in Zodiac water treatment systems.\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe cost of inaction when operating with a depleted cell includes the proliferation of pathogens due to low chlorine production, overheating of the power supply, and inefficient electrical consumption. The \u003cb data-index-in-node=\"212\" data-path-to-node=\"7\"\u003eoriginal Zodiac cell\u003c\/b\u003e resolves these risks through high-purity titanium electrodes with a long-lasting catalytic coating.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8\"\u003eElectrodynamic Performance and Intelligent Self-Cleaning\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"9\"\u003eZodiac Ei and Ei2 chlorinator cell electrode\u003c\/b\u003e stands out for its ability to operate under variable hydraulic conditions without loss of efficiency. Its design allows for the immediate recovery of the chlorinator's nominal performance, ensuring water biosecurity.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eSimplified Technical Replacement:\u003c\/b\u003e The connection system is designed for direct replacement by the operator, minimizing technical downtime.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003ePolarity Reversal Technology:\u003c\/b\u003e The electrodes are self-cleaning, which prevents the accumulation of calcareous deposits and extends the service life of the spare part.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eIndustrial-Grade Materials:\u003c\/b\u003e Manufactured entirely from titanium alloy with a noble metal coating for maximum conductivity.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eProduction Optimization:\u003c\/b\u003e Available in \u003cb data-index-in-node=\"61\" data-path-to-node=\"10,3,0\"\u003e10 g\/h\u003c\/b\u003e, \u003cb data-index-in-node=\"69\" data-path-to-node=\"10,3,0\"\u003e18 g\/h\u003c\/b\u003e, \u003cb data-index-in-node=\"77\" data-path-to-node=\"10,3,0\"\u003e20 g\/h\u003c\/b\u003e, and \u003cb data-index-in-node=\"86\" data-path-to-node=\"10,3,0\"\u003e25 g\/h\u003c\/b\u003e configurations to adapt to different pool volumes.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003eEquipment Compatibility:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli data-path-to-node=\"12,0,0\"\u003eZodiac \u003cb data-index-in-node=\"34\" data-path-to-node=\"12,0,0\"\u003eEi W383520;\u003c\/b\u003e \u003c\/li\u003e\n\n\u003cli data-path-to-node=\"12,0,0\"\u003e\n\n\u003cb data-index-in-node=\"38\" data-path-to-node=\"12,0,0\"\u003eEi2 Expert WW000063;\u003c\/b\u003e \u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eEi2 WW000066\u003c\/strong\u003e;\u003c\/li\u003e\n\n\u003cli data-path-to-node=\"12,0,0\"\u003e\n\n\u003cb data-index-in-node=\"50\" data-path-to-node=\"12,0,0\"\u003eGenSalt OE iQ 77383 - 77386;\u003c\/b\u003e \u003c\/li\u003e\n\n\u003cli data-path-to-node=\"12,0,0\"\u003e\u003cb data-index-in-node=\"62\" data-path-to-node=\"12,0,0\"\u003eGenSalt OT WW000161 - WW000325;\u003c\/b\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cb data-index-in-node=\"62\" data-path-to-node=\"12,0,0\"\u003eGenSalt OE WW000096\u003c\/b\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cb data-index-in-node=\"62\" data-path-to-node=\"12,0,0\"\u003eEi2 iQ 77377 - 77380\u003c\/b\u003e\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,1,0\"\u003eElectrode Material:\u003c\/b\u003e \u003cb data-index-in-node=\"36\" data-path-to-node=\"12,1,0\"\u003eTitanium\u003c\/b\u003e alloy with catalytic coating.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,2,0\"\u003eCleaning System:\u003c\/b\u003e Automatic via \u003cb data-index-in-node=\"36\" data-path-to-node=\"12,2,0\"\u003epolarity reversal\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,3,0\"\u003eAvailable Models:\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,3,1,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,3,1,0,0\"\u003e10 g\/h:\u003c\/b\u003e Reference \u003cb data-index-in-node=\"19\" data-path-to-node=\"12,3,1,0,0\"\u003eR0758800\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,3,1,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,3,1,1,0\"\u003e18 g\/h:\u003c\/b\u003e Reference \u003cb data-index-in-node=\"19\" data-path-to-node=\"12,3,1,1,0\"\u003eR0758900\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,3,1,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,3,1,2,0\"\u003e20 g\/h:\u003c\/b\u003e Reference \u003cb data-index-in-node=\"19\" data-path-to-node=\"12,3,1,2,0\"\u003eR0673700\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,3,1,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,3,1,3,0\"\u003e25 g\/h:\u003c\/b\u003e Reference \u003cb data-index-in-node=\"19\" data-path-to-node=\"12,3,1,3,0\"\u003eR0759000\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13\"\u003eCompatibility and Installation Protocols\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"14\"\u003eThe \u003cb data-index-in-node=\"3\" data-path-to-node=\"14\"\u003eZodiac Ei and Ei2 chlorinator cell electrode\u003c\/b\u003e is compatible with \u003cb data-index-in-node=\"110\" data-path-to-node=\"14\"\u003eEi\u003c\/b\u003e and \u003cb data-index-in-node=\"115\" data-path-to-node=\"14\"\u003eGenSalt\u003c\/b\u003e salt electrolysis platforms. To ensure warranty validity and system efficiency, the cell must be installed in a section of piping with constant flow and downstream of the filtration system.\u003c\/p\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not use with equipment from manufacturers other than Zodiac. The use of non-original cells invalidates the chlorinator's electrical safety certification and may cause irreparable damage to the power board due to impedance mismatch.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16\"\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"17,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"17,0,0\"\u003eHow do I identify which Zodiac cell model I need for my equipment?\u003c\/b\u003e Check the technical label on your power supply or on the old cell. The production capacities (\u003cb data-index-in-node=\"184\" data-path-to-node=\"17,0,0\"\u003e10 g\/h\u003c\/b\u003e, \u003cb data-index-in-node=\"192\" data-path-to-node=\"17,0,0\"\u003e18 g\/h\u003c\/b\u003e, \u003cb data-index-in-node=\"200\" data-path-to-node=\"17,0,0\"\u003e20 g\/h\u003c\/b\u003e, or \u003cb data-index-in-node=\"209\" data-path-to-node=\"17,0,0\"\u003e25 g\/h\u003c\/b\u003e) are specific to each chlorinator model and must be respected to avoid system errors.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"17,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"17,1,0\"\u003eIs it necessary to hire a professional to change the Ei2 Expert cell?\u003c\/b\u003e The \u003cb data-index-in-node=\"79\" data-path-to-node=\"17,1,0\"\u003eoriginal Zodiac cell\u003c\/b\u003e is designed for a simple and quick replacement that can be performed by the owner. It only requires disconnecting the power, removing the depleted cell, and inserting the new spare part by following the integrated alignment guides.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"18\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"18\"\u003eQ-Tech Engineering Support\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"19\"\u003eAt Q-tech.es, we provide specialized technical assistance for the optimization of Zodiac electrolysis systems. If you require support for identifying your model or technical assistance for commissioning, please contact our field engineers by phone or in person.\u003c\/p\u003e","brand":"Zodiac","offers":[{"title":"Zodiac electrolysis cell 10 g\/h R0758800","offer_id":39909210587289,"sku":"ZO-R0758800","price":411.82,"currency_code":"EUR","in_stock":true},{"title":"Zodiac 18 g\/h electrolysis cell R0758900","offer_id":39909210620057,"sku":"ZO-R0758900","price":619.5,"currency_code":"EUR","in_stock":true},{"title":"Zodiac electrolysis cell 20 g\/h R0673700","offer_id":49759880446296,"sku":"ZO-R0673700","price":546.34,"currency_code":"EUR","in_stock":true},{"title":"Zodiac electrolysis cell 25 g\/h R0759000","offer_id":39909210652825,"sku":"ZO-R0759000","price":769.36,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/zodiac-electrodo-celula-para-clorador-ei-de-zodiac-celula-electrolisis-zodiac-10-g-h-r0758800-52965615993176.jpg?v=1702916600","url":"https:\/\/q-tech.es\/en-en\/products\/celula-recambio-zodiac-ei-ei2-gensalt-original","provider":"Q-Tech ® ","version":"1.0","type":"link"}