{"product_id":"celula-recambio-rcb-baja-salinidad-hayward-oxilife-aquascenic","title":"RCB low salinity cell electrode Hayward AQR LS-Sugar Valley-UVScenic-Oxilife-Aquascenic","description":"\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eRCB Cell: Low-Salinity Hydrolysis Engineering\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe \u003cb data-path-to-node=\"6\" data-index-in-node=\"3\"\u003eRCB Low-Salinity Replacement Cell\u003c\/b\u003e is the high-end component designed for hydrolysis disinfection in systems with minimal salt concentrations. This titanium electrode with an optimized coating ensures the generation of high-purity oxidizing agents in low-conductivity water. The cost of inaction when using standard cells in low-salinity equipment includes accelerated coating degradation, excessive electrical consumption increase, and control system failure. The \u003cb data-path-to-node=\"6\" data-index-in-node=\"531\"\u003eRCB Cell\u003c\/b\u003e resolves these operational risks through a plate surface area calculated to operate with maximum efficiency in reduced salinity ranges.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eElectrochemical Performance and Stability in Low Conductivity\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"8\"\u003eThe \u003cb data-path-to-node=\"8\" data-index-in-node=\"3\"\u003eRCB Replacement Cell\u003c\/b\u003e stands out for its plate architecture designed for hydrolysis and advanced disinfection environments. Its manufacturing ensures a long service life and precise monitoring of water status, optimizing the technical maintenance of the installation.\u003c\/p\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003ePremium Coated Titanium Plates:\u003c\/b\u003e The electrodes use a specific noble metal alloy to work under low-conductivity conditions without compromising hydrolysis.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eAdvanced Multi-Brand Compatibility:\u003c\/b\u003e Design validated for \u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"67\"\u003eHayward AquaRite Low Salt\u003c\/b\u003e, \u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"94\"\u003eOxilife\u003c\/b\u003e, \u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"103\"\u003eAquascenic\u003c\/b\u003e, \u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"115\"\u003eUVScenic\u003c\/b\u003e, and \u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"138\"\u003eSugar Valley\u003c\/b\u003e platforms.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eEfficient Water Management:\u003c\/b\u003e Allows for keeping the pool disinfected with imperceptible salt levels, ideal for protecting sensitive linings and metal infrastructure components.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eStability in Polarity Inversion Cycles:\u003c\/b\u003e The plates withstand frequent self-cleaning cycles, maintaining operational efficiency and reducing calcareous sediment buildup.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eMechanical Robustness and Industrial Safety Standards\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"11\"\u003eThe manufacturing of the \u003cb data-path-to-node=\"11\" data-index-in-node=\"21\"\u003eRCB Replacement Cell\u003c\/b\u003e follows industrial protocols for advanced electrochemical instrumentation. Its design allows for rapid, watertight replacement, ensuring operational continuity in high-technical installations.\u003c\/p\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eHigh-Fidelity Connectivity:\u003c\/b\u003e Terminals designed to ensure stable power transmission, minimizing thermal resistance at contact points.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eLong-Life Architecture:\u003c\/b\u003e Reinforced construction to withstand the flow and pressure fluctuations common in high-capacity filtration systems.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eOPEX Optimization:\u003c\/b\u003e By operating efficiently in low salinity, the system reduces stress on the chlorinator power supply, extending the electronic equipment's service life.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eProcess Sustainability:\u003c\/b\u003e Hydrolysis technology reduces dependence on traditional chemicals, improving the water's biological safety naturally.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u0026lt;h4\u0026gt;Technical Specifications\u0026lt;\/h4\u0026gt;\u003c\/p\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eElectrode Material:\u003c\/b\u003e Titanium with precious metal coating for low salinity.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eTechnical Compatibility:\u003c\/b\u003e \u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"24\"\u003eHayward AQR LS\u003c\/b\u003e, \u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"40\"\u003eOxilife\u003c\/b\u003e, \u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"49\"\u003eAquascenic\u003c\/b\u003e, \u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"61\"\u003eUVScenic\u003c\/b\u003e, \u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"71\"\u003eSugar Valley\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eOperational Salinity Range:\u003c\/b\u003e Optimized for low conductivity (\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"66\"\u003e1.5 g\/L\u003c\/b\u003e to \u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"76\"\u003e2 g\/L\u003c\/b\u003e).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eApplied Technology:\u003c\/b\u003e Hydrolysis and low-salinity electrolysis.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"14,4,0\"\u003e\u003cb data-path-to-node=\"14,4,0\" data-index-in-node=\"0\"\u003eConnector Type:\u003c\/b\u003e Heavy-duty terminals for stable power transmission.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"14,5,0\"\u003e\u003cb data-path-to-node=\"14,5,0\" data-index-in-node=\"0\"\u003ePlate Cleaning:\u003c\/b\u003e Compatible with automatic polarity inversion systems.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003eCompatibility and Application Limits\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"16\"\u003eThe \u003cb data-path-to-node=\"16\" data-index-in-node=\"3\"\u003eRCB Low-Salinity Replacement Cell\u003c\/b\u003e is exclusively compatible with systems designed for low conductivity manufactured by Sugar Valley or under Hayward license (LS Series). It must be installed following the indicated flow direction to avoid turbulence that affects the integrated flow switch reading.\u003c\/p\u003e\n\u003cp data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"324\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not use in standard salinity equipment (\u003cb data-path-to-node=\"16\" data-index-in-node=\"391\"\u003e4 g\/L\u003c\/b\u003e or higher), as the coating is specifically designed for low-salt residue conditions. Strict water balance (pH between 7.2 and 7.4) is required to prevent premature plate wear.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"17\"\u003e\u003cb data-path-to-node=\"17\" data-index-in-node=\"0\"\u003eFAQ\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"18\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"18,0,0\"\u003e\u003cb data-path-to-node=\"18,0,0\" data-index-in-node=\"0\"\u003eCan I use this cell in an Oxilife system of any power rating?\u003c\/b\u003e The \u003cb data-path-to-node=\"18,0,0\" data-index-in-node=\"72\"\u003eRCB Replacement Cell\u003c\/b\u003e must be selected according to the specific grams\/hour (\u003cb data-path-to-node=\"18,0,0\" data-index-in-node=\"150\"\u003eg\/h\u003c\/b\u003e) output of your equipment. Check your original model nomenclature to ensure the electrode production capacity matches your controller settings.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"18,1,0\"\u003e\u003cb data-path-to-node=\"18,1,0\" data-index-in-node=\"0\"\u003eWhat benefits does low-salinity technology have over normal chlorination?\u003c\/b\u003e The \u003cb data-path-to-node=\"18,1,0\" data-index-in-node=\"104\"\u003eRCB Cell\u003c\/b\u003e technology allows for water disinfection with a minimal amount of salt. This prevents a salty taste in the water, protects stainless steel components from corrosion, and is much gentler on users' skin and eyes.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"18,2,0\"\u003e\u003cb data-path-to-node=\"18,2,0\" data-index-in-node=\"0\"\u003eHow do I know if my low-salinity cell has reached the end of its service life?\u003c\/b\u003e The system typically indicates \"Low Salt\" or \"Low Output\" persistently, even when manually measured conductivity levels are correct. Physical wear or loss of the dark coating on the titanium plates may also be observed.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"19\"\u003e\u003cb data-path-to-node=\"19\" data-index-in-node=\"0\"\u003eQ-Tech Engineering Support\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"20\"\u003eAt Q-tech.es, we provide specialized technical assistance for configuring low-salinity electrochemical instrumentation. If you require installation support or on-site technical assistance for your \u003cb data-path-to-node=\"20\" data-index-in-node=\"216\"\u003eRCB Replacement Cell\u003c\/b\u003e, please contact our field engineers by phone or in person.\u003c\/p\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: 24px; top: 169.062px;\"\u003e\n\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"Sugar Valley","offers":[{"title":"RCB5 - 8A - HD0 - OX0 hydrolysis cell","offer_id":46909599056216,"sku":"PS-12616","price":525.1,"currency_code":"EUR","in_stock":true},{"title":"RCB 16 hydrolysis cell - 15A - HD1 - OX1","offer_id":46909599088984,"sku":"PS-11382","price":577.02,"currency_code":"EUR","in_stock":true},{"title":"RCB 33 - 30A - HD2 - OX2 hydrolysis cell (2013 or earlier)","offer_id":46909599121752,"sku":"PS-11383","price":932.2,"currency_code":"EUR","in_stock":true},{"title":"RCB 33 - 30A - HD2 - OX2 hydrolysis cell (2014 or later)","offer_id":46909599154520,"sku":"PS-12510","price":879.1,"currency_code":"EUR","in_stock":true},{"title":"RCB 50 - 50A - HD3 - OX3 hydrolysis cell (2015 or earlier)","offer_id":46909599187288,"sku":"PS-11384","price":1162.3,"currency_code":"EUR","in_stock":true},{"title":"RCB 50 - 50A - HD3 - OX3 hydrolysis cell (2016 or later)","offer_id":46909599220056,"sku":"PS-13742","price":1532.82,"currency_code":"EUR","in_stock":true},{"title":"RCB 85 - 80A - HD4 - OX4 hydrolysis cell","offer_id":46909599252824,"sku":"PS-11608","price":3066.82,"currency_code":"EUR","in_stock":true},{"title":"RCB 125 hydrolysis cell - 120A - HD5 - OX5","offer_id":46909599285592,"sku":"PS-11609","price":3953.0,"currency_code":"EUR","in_stock":true},{"title":"RCB 175 - 175A - HD6 - OX6 hydrolysis cell","offer_id":46909599318360,"sku":"PS-11610","price":5662.82,"currency_code":"EUR","in_stock":true},{"title":"RCB 250 Hydrolysis cell - 250A - HD7 - OX7","offer_id":46909599351128,"sku":"PS-11611","price":8118.4,"currency_code":"EUR","in_stock":true},{"title":"RCB 350 - 350A - HD8 - OX8 hydrolysis cell (includes 2 cells)","offer_id":46909599383896,"sku":"PS-11612","price":10472.5,"currency_code":"EUR","in_stock":true},{"title":"RCB 500 - 500A - HD9 - OX9 hydrolysis cell (includes 2 cells)","offer_id":46909599416664,"sku":"PS-11613","price":15338.82,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/sugar-valley-celula-electrodo-para-oxilife-uvscenic-aquascenic-y-da-gen-de-sugar-valley-celula-hidrolisis-8a-hd0-ox0-52965671403864.jpg?v=1702917005","url":"https:\/\/q-tech.es\/en-en\/products\/celula-recambio-rcb-baja-salinidad-hayward-oxilife-aquascenic","provider":"Q-Tech ® ","version":"1.0","type":"link"}