{"product_id":"bomba-dosificadora-peristaltica-ctx-original","title":"CTX peristaltic dosing pump","description":"\u003ch3 data-path-to-node=\"6\"\u003eCTX Peristaltic Pump: High-Fidelity Dosing Engineering\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-path-to-node=\"7\" data-index-in-node=\"3\"\u003eCTX Peristaltic Dosing Pump\u003c\/b\u003e is an engineered component designed for the precise injection of liquid pH correctors or disinfectants. This equipment ensures a constant and controlled flow rate, enabling the treatment system to perform proportional and efficient chemical corrections. The cost of inaction when using low-quality pumps includes erratic injections, reagent overdosing, and accelerated deterioration of technical room equipment. The \u003cb data-path-to-node=\"7\" data-index-in-node=\"483\"\u003eCTX Peristaltic Pump\u003c\/b\u003e solves these operational risks through a stable compression mechanism and linear response to treatment demands.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAnalytical Precision and Operational Stability\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-path-to-node=\"9\" data-index-in-node=\"3\"\u003eCTX Peristaltic Dosing Pump\u003c\/b\u003e stands out for its mechanical architecture, designed for demanding water treatment environments. Its robust body ensures a long service life and minimal drift in delivery flow, optimizing technical maintenance of the installation.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eReinforced Compression Mechanism:\u003c\/b\u003e Manufactured with high-strength rollers that protect the internal tube against premature wear and mechanical deformation.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eConstant Flow Dosing:\u003c\/b\u003e The controlled rotation system minimizes pressure variations, ensuring that the volume of chemical injected is accurate and stable.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eChemically Resistant Casing:\u003c\/b\u003e Made of technical polymers that protect the motor and electronics against corrosive vapors and ambient humidity.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eSilent and Efficient Operation:\u003c\/b\u003e Low-friction motor technology allows for continuous operation with imperceptible noise levels, ideal for compact technical rooms.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMechanical Robustness and Industrial Safety Standards\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003eThe manufacturing of the \u003cb data-path-to-node=\"12\" data-index-in-node=\"21\"\u003eCTX Peristaltic Dosing Pump\u003c\/b\u003e follows Fluidra quality protocols for fluid instrumentation. Its design allows for seamless integration into automatic control systems, ensuring the tightness of the chemical circuit under nominal working pressures.\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eEasy Electrical Integration:\u003c\/b\u003e Designed for perfect synchronization with \u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"92\"\u003epH\u003c\/b\u003e and \u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"97\"\u003eRedox\u003c\/b\u003e controllers, reducing setup time for the overall system.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eFlexible Element Protection:\u003c\/b\u003e Includes a transparent safety cover that allows for visual inspection of the tube's condition without exposing the operator to splashes.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eUniversal Chemical Compatibility:\u003c\/b\u003e The Santoprene tube is suitable for most commercial pH correctors and liquid chlorine solutions.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eSystem Sustainability:\u003c\/b\u003e By maintaining balanced dosing, the pump contributes to the longevity of liners and the biocidal efficiency of disinfectants.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"14\"\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eDelivery Flow:\u003c\/b\u003e \u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"19\"\u003e1.5 l\/h\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eWorking Pressure:\u003c\/b\u003e \u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"20\"\u003e1.5 bar\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eTube Material:\u003c\/b\u003e High chemical compatibility Santoprene.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eProtection Rating:\u003c\/b\u003e \u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"21\"\u003eIP65\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,4,0\"\u003e\u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"0\"\u003ePower Supply:\u003c\/b\u003e \u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"24\"\u003e230V AC\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,5,0\"\u003e\u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"0\"\u003eConnection Type:\u003c\/b\u003e Quick-connect fittings for \u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"47\"\u003e4 x 6 mm\u003c\/b\u003e tubing.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,6,0\"\u003e\u003cb data-path-to-node=\"15,6,0\" data-index-in-node=\"0\"\u003eBody Material:\u003c\/b\u003e Glass fiber reinforced polypropylene.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eCompatibility and Application Limits\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"17\"\u003eThe \u003cb data-path-to-node=\"17\" data-index-in-node=\"3\"\u003eCTX Peristaltic Dosing Pump\u003c\/b\u003e is compatible with all \u003cb data-path-to-node=\"17\" data-index-in-node=\"93\"\u003eCTX MyPool\u003c\/b\u003e series controllers and \u003cb data-path-to-node=\"17\" data-index-in-node=\"115\"\u003eFluidra\u003c\/b\u003e systems. It must be installed on a vertical plane, always above the maximum level of the chemical tank to prevent accidental siphon effects. \u003cb data-path-to-node=\"17\" data-index-in-node=\"271\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not use for injecting viscous chemicals or products with suspended particles that could clog the fittings. Do not run dry for extended periods and perform annual replacement of the Santoprene tube to maintain mechanical integrity.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"0\"\u003eWhy choose the original CTX peristaltic pump?\u003c\/b\u003e The original \u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"58\"\u003eCTX Peristaltic Dosing Pump\u003c\/b\u003e ensures exact compatibility with Fluidra controllers. Generic equipment often offers different shut-off pressures, which leads to leaks or incorrect injections, even if the motor appears to be turning.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"0\"\u003eWhen is it necessary to replace the pump's internal tube?\u003c\/b\u003e It should be replaced annually or if a loss of flow is detected despite the motor running. A fatigued tube has reduced elasticity, which prevents the rollers from properly compressing the section, resulting in a loss of suction capacity.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"0\"\u003eHow can I extend the service life of the dosing motor?\u003c\/b\u003e Keep the pump installed in a dry, ventilated area. Periodically check that the inlet and outlet connections are free of chemical crystallization, as obstruction increases mechanical strain on the motor and accelerates wear.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"20\"\u003e\u003cb data-path-to-node=\"20\" data-index-in-node=\"0\"\u003eQ-Tech Engineering Support\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"21\"\u003eAt Q-tech.es, we provide specialized technical assistance for configuring Fluidra fluid instrumentation. If you require installation support or on-site technical assistance for your \u003cb data-path-to-node=\"21\" data-index-in-node=\"202\"\u003eCTX Peristaltic Dosing Pump\u003c\/b\u003e, please contact our field engineers.\u003c\/p\u003e\n\u003ch3\u003eDocumentation:\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/gestor-doc-s3.s3.eu-west-1.amazonaws.com\/documents\/category\/CTX_57149-50_KIT_Dosing_Pump_2015-2976.pdf\" title=\"CTX peristaltic dosing pump exploded view\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload exploded view - spare parts\u003c\/a\u003e\u003c\/p\u003e","brand":"AstralPool\/CTX","offers":[{"title":"Default Title","offer_id":19488822788184,"sku":"AS57149","price":134.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/astralpool-ctx-bomba-dosificadora-peristaltica-ctx-default-title-52965523882328.jpg?v=1702915911","url":"https:\/\/q-tech.es\/en-en\/products\/bomba-dosificadora-peristaltica-ctx-original","provider":"Q-Tech ® ","version":"1.0","type":"link"}