{"title":"CTX regulators","description":"\u003cp class=\"qt-version\"\u003eFP54·261111\u003c\/p\u003e","products":[{"product_id":"bomba-dosificadora-peristaltica-ctx-original","title":"CTX peristaltic dosing pump","description":"\u003ch3 data-path-to-node=\"6\"\u003eCTX Peristaltic Pump: High-Fidelity Dosing Engineering\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-path-to-node=\"7\" data-index-in-node=\"3\"\u003eCTX peristaltic dosing pump\u003c\/b\u003e is the engineering component designed for the precise injection of pH correctors or liquid disinfectants. This equipment guarantees a constant and controlled flow rate so that the treatment system performs proportional and efficient chemical corrections. The cost of inaction when using low-quality pumps includes erratic injections, chemical overdosing, and accelerated deterioration of technical room equipment. The \u003cb data-path-to-node=\"7\" data-index-in-node=\"483\"\u003eCTX peristaltic pump\u003c\/b\u003e addresses these operational risks through a stable compression mechanism and a linear response to treatment demands.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\n\n\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAnalytical Precision and Operational Stability\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-path-to-node=\"9\" data-index-in-node=\"3\"\u003eCTX peristaltic dosing pump\u003c\/b\u003e stands out for its mechanical architecture designed for demanding water treatment environments. Its robust body ensures a long service life and minimal drift in the delivery flow rate, optimizing the technical maintenance of the installation.\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\n\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eReinforced Compression Mechanism:\u003c\/b\u003e Manufactured with high-strength rollers that protect the internal tube against premature wear and mechanical deformation.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\n\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eConstant Flow Dosing:\u003c\/b\u003e The controlled rotation system minimizes pressure variations, ensuring that the volume of injected chemical is real and stable.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\n\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eChemically Resistant Housing:\u003c\/b\u003e Manufactured from technical polymers that protect the motor and electronics against corrosive vapors and ambient moisture.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\n\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eQuiet and Efficient Operation:\u003c\/b\u003e The low-friction motor technology allows for continuous operation with an imperceptible noise level, ideal for compact technical rooms.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\n\n\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMechanical Robustness and Industrial Safety Standards\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003eThe manufacturing of the \u003cb data-path-to-node=\"12\" data-index-in-node=\"21\"\u003eCTX peristaltic dosing pump\u003c\/b\u003e follows Fluidra's quality protocols for fluid instrumentation. Its design allows for seamless integration into automatic control systems, guaranteeing the tightness of the chemical circuit under nominal working pressures.\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,0,0\"\u003e\n\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eEasy Electrical Integration:\u003c\/b\u003e Designed for perfect synchronization with \u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"92\"\u003epH\u003c\/b\u003e and \u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"97\"\u003eRedox\u003c\/b\u003e controllers, reducing the setup time of the overall system.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,1,0\"\u003e\n\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eFlexible Element Protection:\u003c\/b\u003e Includes a transparent safety cover that allows visual inspection of the tube's condition without exposing the operator to splashes.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,2,0\"\u003e\n\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eUniversal Chemical Compatibility:\u003c\/b\u003e The santoprene tube is suitable for most commercial pH correctors and liquid chlorine solutions.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,3,0\"\u003e\n\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eSystem Sustainability:\u003c\/b\u003e By maintaining balanced dosing, the pump contributes to the longevity of the coatings and the biocidal efficiency of the disinfectants.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"14\"\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,0,0\"\u003e\n\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eDelivery Flow Rate:\u003c\/b\u003e \u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"19\"\u003e1.5 l\/h\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,1,0\"\u003e\n\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eWorking Pressure:\u003c\/b\u003e \u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"20\"\u003e1.5 bar\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,2,0\"\u003e\n\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eTube Material:\u003c\/b\u003e Santoprene with high chemical compatibility.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,3,0\"\u003e\n\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eProtection Rating:\u003c\/b\u003e \u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"21\"\u003eIP65\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,4,0\"\u003e\n\u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"0\"\u003eElectrical Power Supply:\u003c\/b\u003e \u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"24\"\u003e230V AC\u003c\/b\u003e.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,5,0\"\u003e\n\u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"0\"\u003eConnection Type:\u003c\/b\u003e Quick fittings for \u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"47\"\u003e4 x 6 mm\u003c\/b\u003e tubing.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,6,0\"\u003e\n\u003cb data-path-to-node=\"15,6,0\" data-index-in-node=\"0\"\u003eBody Material:\u003c\/b\u003e Glass fiber-reinforced polypropylene.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e\n\n\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eCompatibility and Application Limits\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"17\"\u003eThe \u003cb data-path-to-node=\"17\" data-index-in-node=\"3\"\u003eCTX peristaltic dosing pump\u003c\/b\u003e is compatible with all controllers in the \u003cb data-path-to-node=\"17\" data-index-in-node=\"93\"\u003eCTX MyPool\u003c\/b\u003e series and \u003cb data-path-to-node=\"17\" data-index-in-node=\"115\"\u003eFluidra\u003c\/b\u003e systems. It must be installed vertically, always above the maximum level of the chemical product container to prevent accidental siphoning effects. \u003cb data-path-to-node=\"17\" data-index-in-node=\"271\"\u003eTECHNICAL RESTRICTION:\u003c\/b\u003e Do not use for injecting viscous chemicals or those with suspended particles that could clog the fittings. Do not operate dry for extended periods and replace the santoprene tube annually to maintain mechanical integrity.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"18\"\u003e\n\n\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eFrequently Asked Questions\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,0,0\"\u003e\n\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"0\"\u003eWhy choose the original CTX peristaltic pump?\u003c\/b\u003e The original \u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"58\"\u003eCTX peristaltic dosing pump\u003c\/b\u003e ensures exact compatibility with Fluidra controllers. Generic equipment often offers different shut-off pressures, causing leaks or incorrect injections even if the motor appears to be turning.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,1,0\"\u003e\n\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"0\"\u003eWhen is it necessary to replace the pump's internal tube?\u003c\/b\u003e It should be replaced annually or if you detect a loss of flow rate despite the motor turning. A fatigued tube has reduced elasticity, preventing the rollers from correctly compressing the section, thus losing suction capacity.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"19,2,0\"\u003e\n\u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"0\"\u003eHow can I extend the dosing motor's service life?\u003c\/b\u003e Keep the pump installed in a dry and ventilated place. Periodically check that the inlet and outlet connections do not have chemical product crystallization, as the obstruction increases the mechanical strain on the motor and accelerates wear.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"20\"\u003e\n\n\u003cb data-path-to-node=\"20\" data-index-in-node=\"0\"\u003eQ-Tech Engineering Support\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"21\"\u003eAt Q-tech.es we provide specialized technical assistance for the configuration of Fluidra fluid instrumentation. If you require support for the installation or in-person technical assistance for your \u003cb data-path-to-node=\"21\" data-index-in-node=\"202\"\u003eCTX peristaltic dosing pump\u003c\/b\u003e, contact our field engineers.\u003c\/p\u003e\n\u003ch3\u003eDocumentation:\u003c\/h3\u003e\n\u003cp\u003e\n\u003ca href=\"https:\/\/gestor-doc-s3.s3.eu-west-1.amazonaws.com\/documents\/category\/CTX_57149-50_KIT_Dosing_Pump_2015-2976.pdf\" title=\"CTX peristaltic dosing pump exploded view\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload exploded view - spare parts\u003c\/a\u003e\n\u003c\/p\u003e\n\u003cp class=\"qt-nota-stock\"\u003e\u003cstrong\u003eAvailability and lead times:\u003c\/strong\u003e this item is in stock in our warehouse. Occasionally, depending on the time of year, an error may occur in the stock update. If no units are available at the time of your order, we will order it urgently and immediately inform you of the updated delivery time.\u003c\/p\u003e\n","brand":"CTX","offers":[{"title":"Default Title","offer_id":19488822788184,"sku":"AS57149","price":114.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/astralpool-ctx-bomba-dosificadora-peristaltica-ctx-default-title-52965523882328.jpg?v=1702915911"},{"product_id":"panel-new-vigilant-ctx-ph-rx-y-ph-ppm-de-ph","title":"New Vigilant CTX Panel","description":"\u003cp\u003e- Dosing pumps with single control.\u003c\/p\u003e\n\u003cp\u003e- Power supply: 100-240V - 50\/60 Hz - 30 W.\u003c\/p\u003e\n\u003cp\u003e- Flow rate: 5 l\/h.\u003c\/p\u003e\n\u003cp\u003e- Maximum back pressure: 5 bar.\u003c\/p\u003e\n\u003cp\u003e- On\/off switch.\u003c\/p\u003e\n\u003cp\u003e- 2-line, 16-character multilingual display.\u003c\/p\u003e\n\u003cp\u003e- 8\/12 mm inlet and outlet hydraulic connections.\u003c\/p\u003e\n\u003cp\u003e- Rate: 120 pulses\/minute.\u003c\/p\u003e\n\u003cp\u003e- Includes 1.5-meter pH electrode.\u003c\/p\u003e\n\u003cp\u003e- Includes 1.5-meter RX electrode (on pH\/Rx panel).\u003c\/p\u003e\n\u003cp\u003e- Includes pH 4\/7 and ORP 465mV buffer solutions.\u003c\/p\u003e\n\u003cp\u003e- pH\/ppm measurement ranges:\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003e- 0.00....5.00 ppm Cl2 (0.00...12.00 ppm Br).\u003cbr\u003e- 0.00....14.00 pH, accuracy +\/-0.01 pH.\u003cbr\u003e- -1500....+1500 mV, accuracy +\/-1 mV (sensor not included).\u003cbr\u003e- 0...50ºC, accuracy +\/-0.1ºC (sensor not included).\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e- pH\/RX measurement ranges:\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"padding-left: 30px;\"\u003e\u003cspan\u003e- 0.00....14.00 pH, accuracy +\/-0.01pH\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 30px;\"\u003e\u003cspan\u003e- -1500.... +1500 mV, accuracy +\/-1mV\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 30px;\"\u003e\u003cspan\u003e- 0...50ºC, accuracy +\/-0.1ºC (sensor not included)\u003c\/span\u003e\u003c\/div\u003e","brand":"CTX","offers":[{"title":"New Vigilant pH\/ppm Panel","offer_id":19569136894040,"sku":"AS70256","price":1561.0,"currency_code":"EUR","in_stock":true},{"title":"New Vigilant pH\/ORP Panel","offer_id":19569139810392,"sku":"AS70255","price":1249.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/astralpool-panel-new-vigilant-ctx-ph-rx-y-ph-ppm-de-ph-panel-new-vigilant-ph-ppm-52965536366936.jpg?v=1702916007"},{"product_id":"bomba-dosificadora-ctx-mypool-dos-ph-rx-lcd","title":"CTX MyPool DOS pH Rx peristaltic dosing pump","description":"\u003ch3 data-path-to-node=\"5\"\u003e\n\n\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eCTX MyPool DOS: Precision Engineering in Chemical Control\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eThe \u003c\/span\u003e\n\u003c\/span\u003e\n\u003cb data-path-to-node=\"6\" data-index-in-node=\"3\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eCTX MyPool DOS\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e is a peristaltic dosing pump designed for the automated regulation of pH or Redox potential (ORP) in residential pools. This advanced engineering equipment integrates a microprocessor that manages the proportional injection of chemicals, ensuring perfect water balance.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eThe cost of inaction when operating with manual dosing includes chemical instability, wear on filtration equipment, and health risks for users. The \u003c\/span\u003e\n\u003c\/span\u003e\n\u003cb data-path-to-node=\"7\" data-index-in-node=\"174\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eCTX MyPool DOS\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e addresses these operational risks through constant monitoring and high-fidelity automatic correction.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\n\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eSmart Regulation and Digital Monitoring\u003c\/span\u003e\n\u003c\/span\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eThe \u003c\/span\u003e\n\u003c\/span\u003e\n\u003cb data-path-to-node=\"9\" data-index-in-node=\"3\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eCTX MyPool DOS\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e stands out for its simplified user interface and its immediate response to chemical variations. The system ensures that pH or chlorine levels remain in the optimal range without the need for daily manual intervention.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,0,0\"\u003e\n\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eBacklit LCD Display:\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e High-contrast interface that allows you to view measured values and the pump status in low-light conditions.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,1,0\"\u003e\n\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eProportional Dosing:\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e The equipment reduces the frequency of injection as it approaches the set-point value, preventing overdosing and optimizing chemical consumption.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,2,0\"\u003e\n\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eIndustrial-Grade Housing:\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e Manufactured from technical materials resistant to chemical vapors, meeting the protection standards \u003c\/span\u003e\n\u003c\/span\u003e\n\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"144\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eIP65\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e .\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"10,3,0\"\u003e\n\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eAssisted Calibration:\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e Software optimized for rapid probe calibration, reducing technical maintenance times and reading errors.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\n\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eOperational Safety and IT\/OT Reliability\u003c\/span\u003e\n\u003c\/span\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eThe architecture of the \u003c\/span\u003e\n\u003c\/span\u003e\n\u003cb data-path-to-node=\"12\" data-index-in-node=\"22\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eCTX MyPool DOS\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e is designed for uninterrupted performance in technical rooms. Its robust electronics protect the motor against electrical fluctuations and ensure a longer lifespan than basic dosing systems.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,0,0\"\u003e\n\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eOverdosing Alarm:\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e Safety system that stops the pump if the target value is not reached within a specified time, preventing accidental massive injections.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,1,0\"\u003e\n\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eLevel Sensor Input:\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e Allows the equipment to stop automatically when the chemical container is empty, protecting the peristaltic mechanism against dry running.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,2,0\"\u003e\n\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eProfessional Installation Kit:\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e Includes measuring probe, calibration standard solutions, suction and discharge tubing, and injection fittings for immediate setup.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"13,3,0\"\u003e\n\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003ePeristaltic Maintenance:\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e The design allows for the quick replacement of the Santoprene tubing without removing the equipment from the wall.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"14\"\u003e\n\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eTechnical Specifications\u003c\/span\u003e\n\u003c\/span\u003e\n\n\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,0,0\"\u003e\n\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eDosing Flow Rate: \u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e \u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"24\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e1.5 l\/h\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e .\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,1,0\"\u003e\n\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eMaximum Pressure: \u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e \u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"16\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e1.5 bar\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e .\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,2,0\"\u003e\n\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eProtection Rating: \u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e \u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"21\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eIP65\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e .\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,3,0\"\u003e\n\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eDisplay Type: \u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e \u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"18\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eBacklit LCD\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e .\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,4,0\"\u003e\n\u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003ePower Supply: \u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e \u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"24\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e230V AC\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e \/ \u003c\/span\u003e\n\u003c\/span\u003e\n\u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"34\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e50-60 Hz\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e .\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,5,0\"\u003e\n\u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eTubing Material:\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e Santoprene with high chemical compatibility.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"15,6,0\"\u003e\n\u003cb data-path-to-node=\"15,6,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eDosing mode:\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e Proportional and smart.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e\n\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eCompatibility and Application Limits\u003c\/span\u003e\n\u003c\/span\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"17\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eThe \u003c\/span\u003e\n\u003c\/span\u003e\n\u003cb data-path-to-node=\"17\" data-index-in-node=\"3\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eCTX MyPool DOS\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e is compatible with liquid chlorine, bromine, or pH-lowering systems in residential pools. It must be installed on a vertical wall, always above the maximum level of the chemical container to prevent the siphon effect.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003cp data-path-to-node=\"18\"\u003e\n\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eTECHNICAL RESTRICTION:\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e Do not use with solid or highly viscous chemicals. The equipment requires periodic probe cleaning with specific solutions to maintain reading accuracy below a critical deviation.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"19\"\u003e\n\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eFrequently Asked Questions\u003c\/span\u003e\n\u003c\/span\u003e\n\n\u003c\/h3\u003e\n\u003cul data-path-to-node=\"20\"\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"20,0,0\"\u003e\n\u003cb data-path-to-node=\"20,0,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eWhat makes the CTX MyPool DOS different from a fixed-time pump?\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e The \u003c\/span\u003e\n\u003c\/span\u003e\n\u003cb data-path-to-node=\"20,0,0\" data-index-in-node=\"68\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eCTX MyPool DOS\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e measures the actual condition of the water using a probe. It only injects chemicals when the chemical level deviates from the ideal, which saves chemicals, protects the installation, and ensures a much healthier swim.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"20,1,0\"\u003e\n\u003cb data-path-to-node=\"20,1,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eIs it difficult to calibrate the equipment's probe?\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e Not at all. The LCD menu guides the operator step by step. You only need to immerse the probe in the included standard solution and press a button. The system automatically adjusts the sensitivity to provide industrial precision.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp data-path-to-node=\"20,2,0\"\u003e\n\u003cb data-path-to-node=\"20,2,0\" data-index-in-node=\"0\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eWhat happens if the liquid in the container runs out?\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e If you install the level sensor, the \u003c\/span\u003e\n\u003c\/span\u003e\n\u003cb data-path-to-node=\"20,2,0\" data-index-in-node=\"85\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eCTX MyPool DOS\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e stops automatically and activates an on-screen alert. This prevents the pump from drawing air and protects the motor and tubing from unnecessary wear.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"21\"\u003e\n\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eQ-Tech Engineering Support\u003c\/span\u003e\n\u003c\/span\u003e\n\n\u003c\/h3\u003e\n\u003cp data-path-to-node=\"22\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eAt Q-tech.es, we provide specialized technical assistance for the integration of CTX control systems. If you require a technical audit or support for the installation of your \u003c\/span\u003e\n\u003c\/span\u003e\n\u003cb data-path-to-node=\"22\" data-index-in-node=\"179\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eCTX MyPool DOS\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/b\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e, contact our team of field engineers by phone or in person.\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003ch3\u003e\n\n\u003cspan style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eDocumentation:\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/span\u003e\n\n\u003c\/h3\u003e\n\u003cp\u003e\n\u003ca href=\"https:\/\/gestor-doc-s3.s3.eu-west-1.amazonaws.com\/documents\/category\/manual_mypooldos_en-207014.pdf\" title=\"Download the CTX MyPool DOS installation and user manual\" target=\"_blank\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eDownload user manual\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/a\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\u003ca href=\"http:\/\/spareparts.ctxprofessional.com\/es\/despiece\/72698\" title=\"MyPool DOS pH 1.5L\/H 1.5 BAR 230 VAC CTX spare parts\" target=\"_blank\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\n\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003eSpare parts\u003c\/span\u003e\n\u003c\/span\u003e\n\u003c\/a\u003e\n\u003c\/p\u003e\n\u003cp class=\"qt-nota-stock\"\u003e\u003cstrong\u003eAvailability and lead times:\u003c\/strong\u003e this item is in stock at our warehouse. Occasionally, depending on the time of year, an error may occur in the stock update. If there are no units available at the time of your order, we will order it urgently and inform you immediately of the updated delivery time.\u003c\/p\u003e\n","brand":"CTX","offers":[{"title":"pH sensor","offer_id":39854138425497,"sku":"AS72698","price":289.0,"currency_code":"EUR","in_stock":true},{"title":"Fluidra Connect compatible pH sensor","offer_id":39854138458265,"sku":"AS72712","price":364.0,"currency_code":"EUR","in_stock":true},{"title":"Redox Sensor","offer_id":39854258749593,"sku":"AS72699","price":319.0,"currency_code":"EUR","in_stock":true},{"title":"Fluidra Connect compatible Redox sensor","offer_id":39854263632025,"sku":"AS72711","price":389.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/4592\/8792\/files\/ctx-bomba-dosificadora-peristaltica-mypool-dos-de-ctx-ph-rx-sensor-de-ph-52965611766104.jpg?v=1702916574"}],"url":"https:\/\/q-tech.es\/en-en\/collections\/ctx-ph-regulators.oembed","provider":"Q-Tech ® ","version":"1.0","type":"link"}